Shielding hall of HV PD test

Shielding hall of HV PD test

Application:

HV test shielding room (faraday cage) areWidely used in power cable, transformer, transformer switch, transformer substation and other High voltage levels of partial discharge test or impulse test.

For HV testing shielding room, as a HV test place, it should has good electromagnetic

shielding condition. And its electromagnetic compatibility always is of great importance.

Firstly, it should restrict electromagnetic wave into inside shielding room caused by

discharge when making HV test to weakening interfere to outside, especially on

electronic and communication system. Secondly, it should prevent outer

electromagnetic wave intruding into shielding room to cause measurement error of

partial discharge and wireless. Thirdly, it should reduces open circuit voltage and

closed current to restrain common-mode interference so that to avoid equipment

damage and to improve accuracy of impulse measurement.

For GIS HV test shielding room, design area is 500 m2(Length 25m、Width 20m).

From provided information , we find that steel structure have been completed

already with one set of 20T crane indoor, crane supporting corbel also completed, the

height is 17.9m from ground to upper part of corbel. Main door height 13m,width 10m,

locates at downward of the west side, the door open direction towards to north .

According to ILJIN drawing, three side of structure column has already, but western

structure column still missing yet. however, as the main door will be located in this side,

the western side also should have steel structure , and this structure position still should

be unified considered with main door installation. We will be able to submit suggested

design diagram with position & size of this structure column for reference. in order to

save construction cost, the construction engineering will be carried out by ILJIN

Technical Specification

 Shielding efficiency 0.15 MHz~1.6MHz≥60dB

 reverberation time <5S(at 400Hz 400Hz )

 Background noise level (Ambient level) <5Pc

 Grounding resistance :≤0.5Ω

Background noise can be promised to be not more than 5Pc if no-load equipment

without voltage. (this is what we should to ensure).

 Under equipment running condition ( applied voltage on equipment), user

should check on the whole testing system. such as whether power frequency

testing transformer meets with ambient requirements or not? whether if power

supply has been treated well or not? Whether surrounding other equipment are

placed too close to cause interference or not? And so on. To be honest, And it

seems not directly relevant to background noise level of shielding room .


在线联系供应商

至: CNME Intermational Co.Ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

CT & VT Accuracy Measurement Testing System----General Type
CT & VT Accuracy Measurement Testing System----General Type CT & VT Accuracy Measurement Testing System----General Type Ratio Error and Phase Error of the CT& PT HES Series Control Bench HES-1C ...
Tansformer Insulation Testing  Station design
Tansformer Insulation Testing Station design Tansformer Insulation Testing Station design We will be willing to provide whole-process engineering consulting servicesfor you: Preparingfeasibili...
200Hz /10kvA intermediate frequency generating set
200Hz /10kvA intermediate frequency generating set 200Hz /10kvA intermediate frequency generating set Structure: One set of 4 KW asynchronous motor (3 phase,50Hz,380V,speed 1430 -1440r/min) One se...
impulse Current test system
impulse Current test system impulse Current test system Impulse Current Test Systems are manufactured for testing equipment applied in medium and high voltage transmission &am...
AC Series Resonant Test System
AC Series Resonant Test System AC Series Resonant Test System Applications Resonant Test Systems is appliedfor the generation ofa continuously variable alternating (AC) voltage ...
供应产品

Same products

Air insulated Dry type transformer VPI
Air insulated Dry type transformer VPI 卖方: TAILI ELECTRIC CO.,LTD. Air insulated Dry type transformer VPI TAILI SG(B) air-barrier dry-type transformer( VPI) is des...
Cast Resin Dry Type Transformer with Cooling Fan
Cast Resin Dry Type Transformer with Cooling Fan 卖方: TAILI ELECTRIC CO.,LTD. Cast Resin Dry Type Transformer with Cooling Fan Taili’s advanced epoxy resin casting proc...
1250kVA Dry type Transformer for Bangladesh
1250kVA Dry type Transformer for Bangladesh 卖方: TAILI ELECTRIC CO.,LTD. 1250kVA Dry type Transformer for Bangladesh Taili's advanced epoxy resin casting process ensures...
35kV Dry-type transformer with OLTC
35kV Dry-type transformer with OLTC 卖方: TAILI ELECTRIC CO.,LTD. 35kV Dry-type transformer with OLTC Taili's35kV Dry-type Transformer with OLTC (On-Load Tap Chan...
Cast Resin Dry Type Transformer
Cast Resin Dry Type Transformer 卖方: TAILI ELECTRIC CO.,LTD. Cast Resin Dry Type Transformer IEC/ANSICast Resin TransformersfromTAILI Electric, is difference...