ACREL AM4 MIDDLE VOLTAGE PROTECTIVE RELAYS IN POWER SYSTEMS
ACREL AM4 MIDDLE VOLTAGE PROTECTIVE RELAYS IN POWER SYSTEMS
AM4 middle voltage protective relay coordination in power systemintegrates protection and control, and is suitable for user terminal substations (substations) with a voltage level of 35kV and below, and can realize the protection and control of user substations.It adopts advanced, mature and reliable protection principles and algorithms, with strong anti-interference performance, high reliability, flexible protection implementation, and redundant design for communication. The device has 12 channels of switch value acquisition and 5 channels of relay output, and can cooperate with Acrel-2000Z power monitoring software to realize an unattended end-user substation power distribution automation system.
Specification of AM4 Mains Voltage Relays In Power Systems
|
Rated Parameter |
Power Supply |
Power supply: AC/DC220V, Or AC/DC110V, oR DC48V (Reference the wiring diagram) |
|
Range: Power supply x (1±20%) |
||
|
Maximum power consumption: ≤10W(DC) |
||
|
Rated Voltage |
Rated Voltage: AC100V |
|
|
Range: 1-120V |
||
|
Accuracy: ±0.5% |
||
|
Power Consumption: ≤0.5VA (Single phase) |
||
|
Overload capacity: 1.2 times rated voltage for continuous work; 2 times for 10 seconds |
||
|
Rated Current |
Rated current: AC 5A/1A (See the device wiring diagram) |
|
|
Range: 0.04In~15In |
||
|
Power consumption: ≤0.5VA (Single phase) |
||
|
Overcapacity: 2 times rated current for continuous work; 40 times for 1 second |
||
|
Frequency |
Rated frequency: 50Hz or 60 Hz |
|
|
Range: 45~55Hz |
||
|
Accuracy: ±0.1Hz |
||
|
Digital Input |
Rated Voltage: AC/DC220V, AC/DC110V, DC48V (Similar to power supply) |
|
|
Voltage Range: Rated voltage x (1±20%) |
||
|
Power Consumption: ≤1W(DC220V) (Single channel) |
||
|
Digital Output |
Mechanical life: ≥10000 times |
|
|
Switching capacity: ≥1000W, L/R=40ms |
||
|
On current: continuous≥5A short time (200ms)≥30A |
||
|
Interrupting capacity: ≥30W, L/R=40ms |
||
|
Normal Working Conditions |
Ambient temperature: -10℃~+55℃ |
|
|
Device storage and transport allow the ambient temperature to be -25℃~+70℃ |
||
|
Relative humidity: 5%~95% (The product does |
||
|
Altitude: ≤4000m |
||
Features of AM4 Middle Voltage Protective Relays In Power Systems
01
Abundant interface resources: 4 AC current channels, 4 AC voltage channels; 12 digital input channels (AC and DC), 5 digital output channels; 1 RS485 communication interface, 1 RS232 maintenance port.
02
Transparency: Real-time recording of AC volume, digital input volume, binary output volume, and the status of all protection modules; record the action behavior, action time, and wave recording data of each component inside the protection.
03
High-reliability design: It has passed 6 electromagnetic compatibility testing certifications, and the electrical fast transient burst, electrostatic discharge, and surge anti-interference performance have all reached the IV level standard.
If you want to know more about primary protection in power system, please visit our website.
As one of power meter manufacturers, we will do our best to meet all the needs of customers.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| ACREL AGF-M SOLAR PV DC STRING MONITORING DEVICE | ACREL AGF-M SOLAR PV DC STRING MONITORING DEVICE AGF-M solar energy monitoring deviceis specially used in the intelligent photovoltaic confluence ... | |
| ACREL AKH-0.66/K SPLIT CORE CURRENT TRANSFORMER FOR BUSBAR | ACREL AKH-0.66/K SPLIT CORE CURRENT TRANSFORMER FOR BUSBAR Designed as a split core dc current transducer, Acrel's AKH-0.66/K Split Core DC Curren... | |
| ACREL ACLP10-24 AUXILIARY POWER SUPPLY | ACLP10-24 is a dedicated DC voltage regulator module for instruments, which uses a completely isolated linear transformer. It has the characteristi... | |
| ACREL ACR10R-DXXTEX BIDIRECTIONAL THREE-PHASE REFLUX MONITORING ENERGY METER | ACR10R-DxxTEx bidirectional three-phase re-flux monitoring energy meter is equipped with external Rogowski coils and split-type transformers, which... | |
| ACREL AKH-0.66/K-Φ 333MV SPLIT CURRENT TRANSFORMER | ACREL AKH-0.66/K-Φ 333MV SPLIT CURRENT TRANSFORMER Acrel's Split Type Current Transformer, also known as Split Core Current Sensor, is availab... |
Похожие товары
| 15 Inch Capacitive Touch Screen Panel for Medical & Multi-Application Equipment | Продавец: SEMIJEI TECHNOLOGY LTD | 15 Inch Capacitive Touch Screen Panel for Medical & Multi-Application Equipment 15 Inch Capa... | |
| Custom Size 11.6 Inch Circular Shape Touch Screen With ILITEK Controller | Продавец: SEMIJEI TECHNOLOGY LTD | Custom Size 11.6 Inch Circular Shape Touch Screen With ILITEK Controller Semijei-Tech's11.6 inch... | |
| 10.6 Inch Custom Shape Touch Screen With Multi-Touch for Commercial Systems | Продавец: SEMIJEI TECHNOLOGY LTD | Semijei-Tech's10.6 inch custom shape touch screenis a projected capacitive touch panel develope... | |
| Semijei-Tech's 10.1 inch | Продавец: SEMIJEI TECHNOLOGY LTD | Semijei-Tech's10.1 inch waterproof mirror glass multi-touch panelcombines projected capacitive to... | |
| 7" I²C Glove Touch Capacitive Touch Panel | Продавец: SEMIJEI TECHNOLOGY LTD | 7" I²C Glove Touch Capacitive Touch Panel 7 Inch Glove Touch Capacitive Touch Panelfor Indu... |