ACREL AM4 MIDDLE VOLTAGE PROTECTIVE RELAYS IN POWER SYSTEMS

ACREL AM4 MIDDLE VOLTAGE PROTECTIVE RELAYS IN POWER SYSTEMS

AM4 middle voltage protective relay coordination in power systemintegrates protection and control, and is suitable for user terminal substations (substations) with a voltage level of 35kV and below, and can realize the protection and control of user substations.It adopts advanced, mature and reliable protection principles and algorithms, with strong anti-interference performance, high reliability, flexible protection implementation, and redundant design for communication. The device has 12 channels of switch value acquisition and 5 channels of relay output, and can cooperate with Acrel-2000Z power monitoring software to realize an unattended end-user substation power distribution automation system.

Specification of AM4 Mains Voltage Relays In Power Systems

Rated Parameter

Power Supply

Power supply: AC/DC220V, Or AC/DC110V, oR DC48V (Reference the wiring diagram)

Range: Power supply x (1±20%)

Maximum power consumption: ≤10W(DC)

Rated Voltage

Rated Voltage: AC100V

Range: 1-120V

Accuracy: ±0.5%

Power Consumption: ≤0.5VA (Single phase)

Overload capacity: 1.2 times rated voltage for continuous work; 2 times for 10 seconds

Rated Current

Rated current: AC 5A/1A (See the device wiring diagram)

Range: 0.04In~15In

Power consumption: ≤0.5VA (Single phase)

Overcapacity: 2 times rated current for continuous work; 40 times for 1 second

Frequency

Rated frequency: 50Hz or 60 Hz

Range: 45~55Hz

Accuracy: ±0.1Hz

Digital Input

Rated Voltage: AC/DC220V, AC/DC110V, DC48V (Similar to power supply)

Voltage Range: Rated voltage x (1±20%)

Power Consumption: ≤1W(DC220V) (Single channel)

Digital Output

Mechanical life: ≥10000 times

Switching capacity: ≥1000W, L/R=40ms

On current: continuous≥5A short time (200ms)≥30A

Interrupting capacity: ≥30W, L/R=40ms

Normal Working Conditions

Ambient temperature: -10℃~+55℃

Device storage and transport allow the ambient temperature to be -25℃~+70℃

Relative humidity: 5%~95% (The product does

Altitude: ≤4000m

Features of AM4 Middle Voltage Protective Relays In Power Systems

01

Abundant interface resources: 4 AC current channels, 4 AC voltage channels; 12 digital input channels (AC and DC), 5 digital output channels; 1 RS485 communication interface, 1 RS232 maintenance port.

02

Transparency: Real-time recording of AC volume, digital input volume, binary output volume, and the status of all protection modules; record the action behavior, action time, and wave recording data of each component inside the protection.

03

High-reliability design: It has passed 6 electromagnetic compatibility testing certifications, and the electrical fast transient burst, electrostatic discharge, and surge anti-interference performance have all reached the IV level standard.

If you want to know more about primary protection in power system, please visit our website.

As one of power meter manufacturers, we will do our best to meet all the needs of customers.


在线联系供应商

至: Jiangsu Acrel Micro-grid Research&Development Institute
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

ACREL AMC48-AI AC SINGLE PHASE CURRENT METER
ACREL AMC48-AI AC SINGLE PHASE CURRENT METER ACREL AMC48-AI AC SINGLE PHASE CURRENT METER Acrel's AMC48-AI AC single phase current meteris a digital energy meter with RS485 communication capa...
AGF-AE SERIES PV/SOLAR INVERTER ENERGY METER
AGF-AE SERIES PV/SOLAR INVERTER ENERGY METER AGF-AE Series PV/Solar Inverter Meter, as the key components of anti-backflow detection, adopts high-performance MCU and high-precision metering ch...
ACREL ADL200 SINGLE PHASE ELECTRIC METER WITH MODBUS
ACREL ADL200 SINGLE PHASE ELECTRIC METER WITH MODBUS Single-phase electronic energy meter AcrelADL200is mainly used to measure single-phase active energy of low-voltage network, and can measure voltag...
ACREL AHKC-EKB (200-1000A)/5V OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE)
ACREL AHKC-EKB (200-1000A)/5V OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE) ACREL AHKC-EKB (200-1000A)/5V OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE) AHKC-EKB hall split core current sensorcan collect main incoming line ...
ACREL AMC72-DI DC AMPER METER
ACREL AMC72-DI DC AMPER METER ACREL AMC72-DI DC AMPER METER AMC72-DI digital dc ampere metrebelongs to AMC series programmable intelligent electrical measuring instrument, whic...
供应产品

Same products

Air insulated Dry type transformer VPI
Air insulated Dry type transformer VPI 卖方: TAILI ELECTRIC CO.,LTD. Air insulated Dry type transformer VPI TAILI SG(B) air-barrier dry-type transformer( VPI) is des...
Cast Resin Dry Type Transformer with Cooling Fan
Cast Resin Dry Type Transformer with Cooling Fan 卖方: TAILI ELECTRIC CO.,LTD. Cast Resin Dry Type Transformer with Cooling Fan Taili’s advanced epoxy resin casting proc...
1250kVA Dry type Transformer for Bangladesh
1250kVA Dry type Transformer for Bangladesh 卖方: TAILI ELECTRIC CO.,LTD. 1250kVA Dry type Transformer for Bangladesh Taili's advanced epoxy resin casting process ensures...
35kV Dry-type transformer with OLTC
35kV Dry-type transformer with OLTC 卖方: TAILI ELECTRIC CO.,LTD. 35kV Dry-type transformer with OLTC Taili's35kV Dry-type Transformer with OLTC (On-Load Tap Chan...
Cast Resin Dry Type Transformer
Cast Resin Dry Type Transformer 卖方: TAILI ELECTRIC CO.,LTD. Cast Resin Dry Type Transformer IEC/ANSICast Resin TransformersfromTAILI Electric, is difference...