Safety Mat Safety Relay

Safety Mat Safety Relay

Automation safetyrelay modules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function controllers safety relay offer 2 or 4-wire safety mats/edges. Automatic reset and monitored manual reset are available.

The programmable safety relays support 3 safety output contacts (N/O) and 1 auxiliary output contacts (N/C) or 2NO+1NC+1SO or 2NO(t)+1NC(t).

Features & Advantages of Safety MatRelay

2-wire safety mats/edge

4-wire safety mats/edge

Automatic reset

Monitored manual reset

Parameter of Safety Mat Safety Relay

CZSR8301-3A1B

CZSR8301-3A1B(M)

CZSR8302-3A1B

CZSR8303-3A1B

Supply voltage

24V DC/AC

24V DC/AC

24V DC/AC

100V~230V AC

Voltage tolerance

-

Current consumption

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤7 VA (220V AC)

Input current

≤50mA (24V DC)

≤50mA (24V DC)

≤10mA (24V DC)

≤10mA (220V AC)

Cable resistance

≤15Ω

≤15Ω

≤15Ω

≤15Ω

Input devices

Safety mats (4-wire)

Safety mats (4-wire)

Safety mats (4-wire)

Safety mats, safety edges (2 or 4-wire)

Number of contacts

3NO+1NC

3NO+1NC

3NO+1NC

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

External contact fuse protection

10A gL/gG NEOZED (NO);

10A gL/gG NEOZED (NO);

10A gL/gG NEOZED (NO);

10A gL/gG NEOZED (NO);

6A gL/gG NEOZED (NC)

6A gL/gG NEOZED (NC)

6A gL/gG NEOZED (NC)

6A gL/gG NEOZED (NC)

Mechanical endurance of contacts

≥107

≥107

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:

In accordance with EN60947-5-1:

In accordance with EN60947-5-1:

In accordance with EN60947-5-1:

AC-15, 5A/230V; DC-13, 5A/24V

AC-15, 5A/230V; DC-13, 5A/24V

AC-15, 5A/230V; DC-13, 5A/24V

AC-15, 5A/230V; DC-13, 5A/24V

Switch-on delay

≤300ms

≤150ms

≤300ms

≤300ms

Delay-on de-energisation

≤30ms

≤30ms

≤30ms

≤30ms

Recovery time

≤300ms

≤300ms

≤100ms

≤500ms

Supply short interruption

20ms

20ms

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;

Vibration frequency: 10Hz~55Hz;

Vibration frequency: 10Hz~55Hz;

Vibration frequency: 10Hz~55Hz;

Vibration amplitude: 0.35mm

Vibration amplitude: 0.35mm

Vibration amplitude: 0.35mm

Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

2

2

Rated insulation voltage

250V AC

250V AC

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

SIL3

SIL3

Performance level

PLe

PLe

PLe

PLe

Category

CZSR8302-2A1B1S

CZSR8302-2AT1BT1S

Supply voltage

24V DC/AC

24V DC/AC

Voltage tolerance

Current consumption

≤120mA (24V DC), ≤300mA (24V AC)

≤120mA (24V DC), ≤300mA (24V AC)

Input current

≤10mA (24V DC)

≤10mA (24V DC)

Cable resistance

≤15Ω

≤15Ω

Input devices

Safety mats, safety edges (2 or 4-wire)

Safety switches, Contact switches

Terminal resistance

Number of contacts

2NO+1NC+1SO

2NO(t)+1NC(t)

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

External contact fuse protection

10A gL/gG NEOZED (NO);

10A gL/gG NEOZED (NO);

6A gL/gG NEOZED (NC)

6A gL/gG NEOZED (NC)

Mechanical endurance of contacts

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:

In accordance with EN60947-5-1:

AC-15, 5A/230V; DC-13, 5A/24V

AC-15, 5A/230V; DC-13, 5A/24V

Semiconductor output data

Number of semi-output:1SO

Number of semi-output:1SO

Driving ability:20mA/24V DC

Driving ability:20mA/24V DC

Switch-on delay

≤300ms

≤300ms

Delay-on de-energisation

≤30ms(instantaneous)

≤30ms (instantaneous)

0s, 0.5s, 1s, 2s, 3s, 5s(Deleted factory set as 5s)

Recovery time

≤100ms

≤100ms

Supply short interruption

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;

Vibration frequency: 10Hz~55Hz;

Vibration amplitude: 0.35mm

Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

Rated insulation voltage

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

Performance level

PLe

PLe

Category



Отправить запрос, связаться с поставщиком

Кому: Shanghai Chenzhu Instrument Co., Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

DC Power SPD
DC Power SPD Like all outdoor buildings, photovoltaic devices are vulnerable to lightning strikes. By far the biggest culprit for the power surges that damage s...
CZ3000 Temperature Converter Signal Conditioner
CZ3000 Temperature Converter Signal Conditioner Thermal resistance type isolator, the two-wire or three-wire system resistance signal is converted into 0/4~20mA current signal isolation or 0/1~5V...
40KA AC Power SPD
40KA AC Power SPD SPD for AC power; 220VAC, TN system, Single phase; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication Features & Adva...
Conceptual Difference Between Temperature Transmitter and Temperature Sensor
Conceptual Difference Between Temperature Transmitter and Temperature Sensor differential temperature transmitterand temperature sensor The temperature sensor is a general term for devices that can sense a prescribed me...
Antennas And Feeders SPD
Antennas And Feeders SPD Antennas feeders SPD is used in the antenna feeder circuit of the radio communication station to suppress the induced lightning waves from the ante...
Все товары поставщика

Похожие товары

NITROGEN CABINET
NITROGEN CABINET Продавец: Kunshan Gaoqiang Industrial Equipment Co.,Ltd Dryzone dry nitrogen box has a fast recovery time which is important for some industry demand, es...
Guitar Dry Cabinet
Guitar Dry Cabinet Продавец: Kunshan Gaoqiang Industrial Equipment Co.,Ltd To give performers a better storage environment, Dryzone provides quality dry cabinets for instru...
INDUSTRIAL DRYING CABINET
INDUSTRIAL DRYING CABINET Продавец: Kunshan Gaoqiang Industrial Equipment Co.,Ltd Drying Cabinet for Sale Dryzone industrial commercial drying cabinets are designed for electroni...
DIGITAL HYGROMETER
DIGITAL HYGROMETER Продавец: Kunshan Gaoqiang Industrial Equipment Co.,Ltd Dryzone digital hygro meter could help manage the temperature and humidity of the production line...
Dryzone Nitrogen Desiccator Cabinet
Dryzone Nitrogen Desiccator Cabinet Продавец: Kunshan Gaoqiang Industrial Equipment Co.,Ltd Dryzone Nitrogen desiccator cabinetis 1-50% RH adjustable and it has two series, one is the CQB s...