Safety Mat Safety Relay
Safety Mat Safety Relay
Automation safetyrelay modules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function controllers safety relay offer 2 or 4-wire safety mats/edges. Automatic reset and monitored manual reset are available.
The programmable safety relays support 3 safety output contacts (N/O) and 1 auxiliary output contacts (N/C) or 2NO+1NC+1SO or 2NO(t)+1NC(t).
Features & Advantages of Safety MatRelay
2-wire safety mats/edge
4-wire safety mats/edge
Automatic reset
Monitored manual reset
Parameter of Safety Mat Safety Relay
CZSR8301-3A1B |
CZSR8301-3A1B(M) |
CZSR8302-3A1B |
CZSR8303-3A1B |
|
Supply voltage |
24V DC/AC |
24V DC/AC |
24V DC/AC |
100V~230V AC |
Voltage tolerance |
- |
|||
Current consumption |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤7 VA (220V AC) |
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤10mA (24V DC) |
≤10mA (220V AC) |
Cable resistance |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
Input devices |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats, safety edges (2 or 4-wire) |
Number of contacts |
3NO+1NC |
3NO+1NC |
3NO+1NC |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
External contact fuse protection |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
≥107 |
≥107 |
Utilisation category |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤150ms |
≤300ms |
≤300ms |
Delay-on de-energisation |
≤30ms |
≤30ms |
≤30ms |
≤30ms |
Recovery time |
≤300ms |
≤300ms |
≤100ms |
≤500ms |
Supply short interruption |
20ms |
20ms |
20ms |
20ms |
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
Vibration |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
Relative humidity |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
Elevation |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
Overvoltage category |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅲ |
Pollution degree |
2 |
2 |
2 |
2 |
Rated insulation voltage |
250V AC |
250V AC |
250V AC |
250V AC |
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
Safety integrity level |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
Performance level |
PLe |
PLe |
PLe |
PLe |
Category |
CZSR8302-2A1B1S |
CZSR8302-2AT1BT1S |
|
Supply voltage |
24V DC/AC |
24V DC/AC |
Voltage tolerance |
||
Current consumption |
≤120mA (24V DC), ≤300mA (24V AC) |
≤120mA (24V DC), ≤300mA (24V AC) |
Input current |
≤10mA (24V DC) |
≤10mA (24V DC) |
Cable resistance |
≤15Ω |
≤15Ω |
Input devices |
Safety mats, safety edges (2 or 4-wire) |
Safety switches, Contact switches |
Terminal resistance |
||
Number of contacts |
2NO+1NC+1SO |
2NO(t)+1NC(t) |
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
External contact fuse protection |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
Utilisation category |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
|
Semiconductor output data |
Number of semi-output:1SO |
Number of semi-output:1SO |
Driving ability:20mA/24V DC |
Driving ability:20mA/24V DC |
|
Switch-on delay |
≤300ms |
≤300ms |
Delay-on de-energisation |
≤30ms(instantaneous) |
≤30ms (instantaneous) |
0s, 0.5s, 1s, 2s, 3s, 5s(Deleted factory set as 5s) |
||
Recovery time |
≤100ms |
≤100ms |
Supply short interruption |
20ms |
20ms |
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
Vibration |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
Relative humidity |
10%~90% |
10%~90% |
Elevation |
≤2000m |
≤2000m |
Overvoltage category |
Ⅲ |
Ⅲ |
Pollution degree |
2 |
2 |
Rated insulation voltage |
250V AC |
250V AC |
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
Safety integrity level |
SIL3 |
SIL3 |
Performance level |
PLe |
PLe |
Category |
Send product request
Other supplier products
E-Stop Button, Safety Gate Safety Relay | CHENZHU e stop safety relayare suitable for the application of emergency Stop button and safety gate. Support 2 safety output contacts (N/O) and 2 ... | |
DO Signal (SIS) Input 24V DC 5A Safety Relay | These safety relay are suitable for the application of E-Stop button, safety gate and DO signal from SIS, with several contacts output. The emer... | |
Photovoltaic 1000 DC Power SPD | SPD for DC power, 1000v spd; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features & Advantages of Photovoltai... | |
GS8500-EX Digital Intrinsic Safety Barrier | Digital input, relay output isolated barrier, transfers digital signals (dry contact or NAMUR proximity switch) from hazardous area to safe area. E... | |
Temperature Transmitter | CHENZHU, a reliable temperature transmitter manufacturers, provides a large range of head-mounted temperature transmitters at an affordable price. ... |
Same products
NITROGEN CABINET | Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd | Dryzone dry nitrogen box has a fast recovery time which is important for some industry demand, es... | |
Guitar Dry Cabinet | Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd | To give performers a better storage environment, Dryzone provides quality dry cabinets for instru... | |
INDUSTRIAL DRYING CABINET | Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd | Drying Cabinet for Sale Dryzone industrial commercial drying cabinets are designed for electroni... | |
DIGITAL HYGROMETER | Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd | Dryzone digital hygro meter could help manage the temperature and humidity of the production line... | |
Dryzone Nitrogen Desiccator Cabinet | Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd | Dryzone Nitrogen desiccator cabinetis 1-50% RH adjustable and it has two series, one is the CQB s... |