Safety Mat Safety Relay

Safety Mat Safety Relay

Automation safetyrelay modules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function controllers safety relay offer 2 or 4-wire safety mats/edges. Automatic reset and monitored manual reset are available.

The programmable safety relays support 3 safety output contacts (N/O) and 1 auxiliary output contacts (N/C) or 2NO+1NC+1SO or 2NO(t)+1NC(t).

Features & Advantages of Safety MatRelay

2-wire safety mats/edge

4-wire safety mats/edge

Automatic reset

Monitored manual reset

Parameter of Safety Mat Safety Relay

CZSR8301-3A1B

CZSR8301-3A1B(M)

CZSR8302-3A1B

CZSR8303-3A1B

Supply voltage

24V DC/AC

24V DC/AC

24V DC/AC

100V~230V AC

Voltage tolerance

-

Current consumption

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤7 VA (220V AC)

Input current

≤50mA (24V DC)

≤50mA (24V DC)

≤10mA (24V DC)

≤10mA (220V AC)

Cable resistance

≤15Ω

≤15Ω

≤15Ω

≤15Ω

Input devices

Safety mats (4-wire)

Safety mats (4-wire)

Safety mats (4-wire)

Safety mats, safety edges (2 or 4-wire)

Number of contacts

3NO+1NC

3NO+1NC

3NO+1NC

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

External contact fuse protection

10A gL/gG NEOZED (NO);

10A gL/gG NEOZED (NO);

10A gL/gG NEOZED (NO);

10A gL/gG NEOZED (NO);

6A gL/gG NEOZED (NC)

6A gL/gG NEOZED (NC)

6A gL/gG NEOZED (NC)

6A gL/gG NEOZED (NC)

Mechanical endurance of contacts

≥107

≥107

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:

In accordance with EN60947-5-1:

In accordance with EN60947-5-1:

In accordance with EN60947-5-1:

AC-15, 5A/230V; DC-13, 5A/24V

AC-15, 5A/230V; DC-13, 5A/24V

AC-15, 5A/230V; DC-13, 5A/24V

AC-15, 5A/230V; DC-13, 5A/24V

Switch-on delay

≤300ms

≤150ms

≤300ms

≤300ms

Delay-on de-energisation

≤30ms

≤30ms

≤30ms

≤30ms

Recovery time

≤300ms

≤300ms

≤100ms

≤500ms

Supply short interruption

20ms

20ms

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;

Vibration frequency: 10Hz~55Hz;

Vibration frequency: 10Hz~55Hz;

Vibration frequency: 10Hz~55Hz;

Vibration amplitude: 0.35mm

Vibration amplitude: 0.35mm

Vibration amplitude: 0.35mm

Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

2

2

Rated insulation voltage

250V AC

250V AC

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

SIL3

SIL3

Performance level

PLe

PLe

PLe

PLe

Category

CZSR8302-2A1B1S

CZSR8302-2AT1BT1S

Supply voltage

24V DC/AC

24V DC/AC

Voltage tolerance

Current consumption

≤120mA (24V DC), ≤300mA (24V AC)

≤120mA (24V DC), ≤300mA (24V AC)

Input current

≤10mA (24V DC)

≤10mA (24V DC)

Cable resistance

≤15Ω

≤15Ω

Input devices

Safety mats, safety edges (2 or 4-wire)

Safety switches, Contact switches

Terminal resistance

Number of contacts

2NO+1NC+1SO

2NO(t)+1NC(t)

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

External contact fuse protection

10A gL/gG NEOZED (NO);

10A gL/gG NEOZED (NO);

6A gL/gG NEOZED (NC)

6A gL/gG NEOZED (NC)

Mechanical endurance of contacts

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:

In accordance with EN60947-5-1:

AC-15, 5A/230V; DC-13, 5A/24V

AC-15, 5A/230V; DC-13, 5A/24V

Semiconductor output data

Number of semi-output:1SO

Number of semi-output:1SO

Driving ability:20mA/24V DC

Driving ability:20mA/24V DC

Switch-on delay

≤300ms

≤300ms

Delay-on de-energisation

≤30ms(instantaneous)

≤30ms (instantaneous)

0s, 0.5s, 1s, 2s, 3s, 5s(Deleted factory set as 5s)

Recovery time

≤100ms

≤100ms

Supply short interruption

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;

Vibration frequency: 10Hz~55Hz;

Vibration amplitude: 0.35mm

Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

Rated insulation voltage

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

Performance level

PLe

PLe

Category



Send product request

To: Shanghai Chenzhu Instrument Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

E-Stop Button, Safety Gate Safety Relay
E-Stop Button, Safety Gate Safety Relay CHENZHU e stop safety relayare suitable for the application of emergency Stop button and safety gate. Support 2 safety output contacts (N/O) and 2 ...
DO Signal (SIS) Input 24V DC 5A Safety Relay
DO Signal (SIS) Input 24V DC 5A Safety Relay These safety relay are suitable for the application of E-Stop button, safety gate and DO signal from SIS, with several contacts output. The emer...
Photovoltaic 1000 DC Power SPD
Photovoltaic 1000 DC Power SPD SPD for DC power, 1000v spd; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features & Advantages of Photovoltai...
GS8500-EX Digital Intrinsic Safety Barrier
GS8500-EX Digital Intrinsic Safety Barrier Digital input, relay output isolated barrier, transfers digital signals (dry contact or NAMUR proximity switch) from hazardous area to safe area. E...
Temperature Transmitter
Temperature Transmitter CHENZHU, a reliable temperature transmitter manufacturers, provides a large range of head-mounted temperature transmitters at an affordable price. ...
All supplier products

Same products

NITROGEN CABINET
NITROGEN CABINET Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd Dryzone dry nitrogen box has a fast recovery time which is important for some industry demand, es...
Guitar Dry Cabinet
Guitar Dry Cabinet Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd To give performers a better storage environment, Dryzone provides quality dry cabinets for instru...
INDUSTRIAL DRYING CABINET
INDUSTRIAL DRYING CABINET Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd Drying Cabinet for Sale Dryzone industrial commercial drying cabinets are designed for electroni...
DIGITAL HYGROMETER
DIGITAL HYGROMETER Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd Dryzone digital hygro meter could help manage the temperature and humidity of the production line...
Dryzone Nitrogen Desiccator Cabinet
Dryzone Nitrogen Desiccator Cabinet Seller: Kunshan Gaoqiang Industrial Equipment Co.,Ltd Dryzone Nitrogen desiccator cabinetis 1-50% RH adjustable and it has two series, one is the CQB s...