Reason Analysis of Using AOC Active Optical Cable in Data Center Wiring

40G/100G AOC active optical cable has been globally introduced throughout the aoc data centerfield. Compared to 40G DAC copper cable, 40G AOC active optical cable has unparalleled advantages in data transmission environment above 7 meters, including the smaller size, lighter weight, easier bending, easier management, longer signal transmission distance, etc. In the data center, the same goals can be achieved with a 40G SR4 optical transceiver. The differences between 40G AOC active optical cable and SR4 optical transceiver are analyzed as follows:

With the same transmission distance, for SR4 optical transceiver, different optical fiber jumpers that are connected to the same module will produce different insertion loss and return loss, which is basically a common problem. However, as long as the variation is within the range, there will be no significant change in the eye map and other related indexes.

The AOC active optical cable which is well made is basically stable and has better rocking performance. The repeated test of the SR4 optical transceiver produced a large fluctuation.

It is measured at four combinations of input voltage and signal amplitude to ensure that the performance can be maintained at both the lowest and highest voltages and temperatures. AOC active optical cable is required to pass quadrant tests with a wide temperature range to ensure that the MPO interface and cable of AOC will not melt at high temperatures. The performance change of MPO interface itself at high and low temperatures can meet the change of 0.3 dB, and the materials used are PEI materials that can resist the temperature of above 120 degrees.

As an all-in-one product, the all-in-one test ensures the performance of the product, which may be more stable than SR4 optical transceiver that adopts MPO jumper with uncertain performance. Compared with SR4 optical transceiver that confirms the quality through optical eye diagram, AOC active optical cable mainly uses the eye diagram to judge the quality of indicators.

QSFP+ SR4 optical transceiver has the DDM monitoring function. When receiving coupling, the ADC value of the receiver can be monitored in real time to determine the optimal coupling. Therefore, SR4 is more superior than AOC in terms of receiving sensitivity.

There is not much difference in the OM3 fibers, but the 40G QSFP+ SR4 optical transceiver provides better performance control. QSFP+SR4 is recommended if you want to achieve a longer distance (> 300 m) transmission.

Active fiber optical cable (AOC) is recommended based on the data connection in the data center, because it provides better wiring consistency and repeatability, and the closed ends are easier to avoid the effects of environmental and vibration oscillations. If there is a failure, it can be replaced directly without the need to carry out a series of end-to-plug tests of 40G QSFP+SR4 optical transceiver and MPO jumper on site, which is more beneficial to save costs.

There are many fiber optic accessories suppliers, but we are one of the best choices for you.



Отправить запрос, связаться с поставщиком

Кому: Sumbexauto
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

25G SPF28 AOC
25G SPF28 AOC 25GSFP28 AOC TSCommunicationTSSP-8525G-xxxC is a single-Channel, Pluggable, Fiber-Optic SPF28for 25 Gigabit Ethernet and Infiniband EDR Applicatio...
STANDARD FIBER OPTIC CABLE PATCH CORD
STANDARD FIBER OPTIC CABLE PATCH CORD Fiber Patch Cord or jumper is a fiber cable that has fiber connectors terminated on one or both ends. General use of these cable assemblies include...
QSFP28 100G CWDM4 10KM
QSFP28 100G CWDM4 10KM QSFP28 100G CWDM4 10KM The QSFP28 100G-CWDM4-10km module is a highly integrated 4x28G transceiver focused on reach, bandwidth, density and cost for...
GRADE B PATCH CORD
GRADE B PATCH CORD T&S grade B patch cord connectoris the patchcordwith the random mating performance of Grade B as IEC-61753-1 defined, more than 97% of maximum ...
40G QSFP+ TO 4SFP+ DAC
40G QSFP+ TO 4SFP+ DAC QSFP+ Direct Attach Cables are compliant with the SFF-8436 specifications. 40g harness cableiscompliant with the SFF-8431, SFF-8432 and SFF-8472 sp...
Все товары поставщика

Похожие товары

Steel Fiber For Industrial Floors
Steel Fiber For Industrial Floors Продавец: Tengzhou Star Smith Metal Products Co.,Ltd Steel Fiber For Industrial Floors Steel fiber reinforced concrete industrial building ground ...
Orivision DVI Extender
Orivision DVI Extender Продавец: Nantong ZYDZ Electronic Co., Ltd. Orivision DVI Extender ORIVISION offers a wide selection of products for extending DVI video, aud...
Orivision H.265 1080P@60 IP To SDI Video Decoder With Loop Out
Orivision H.265 1080P@60 IP To SDI Video Decoder With Loop Out Продавец: Nantong ZYDZ Electronic Co., Ltd. Brand: ORIVISION Model: ZY-DS931 Input Interface: LAN Port*1 Output Interface: SDI*2, audio*1 Vid...
The Difference Between Fiber Patch Cord and Fiber Pigtail
The Difference Between Fiber Patch Cord and Fiber Pigtail Продавец: Sumbexauto The Difference Between Fiber Patch Cord and Fiber Pigtail Fiber pigtails patch cordsare cables d...
 The Difference Between 100G QSFP28 Fiber Optical Transceiver and 100G CFP4 Fiber Optical Transceiver
The Difference Between 100G QSFP28 Fiber Optical Transceiver and 100G CFP4 Fiber Optical Transceiver Продавец: Sumbexauto The100g optical transceiveris an optoelectronic device that performs electro-optical and photoele...