Plastic Insulated Control Cable
Plastic Insulated Control Cable
Product Standard
GB/ T 9330- 2008
Usage
This product is suitable for use in AC rate voltage 450/750 V an below control . Monitor return circuit and protection circuit and other occasions.
Property for use
For cable with armor or copper belt sheath structure, should be not less than 12 times of cable overall diameter; Forsoft control cablewith sheath layer structure, should be not less than 6 times of cable overall diameter.
Our Control Cableis suitable for use in AC rate voltage 450/750 V an below control . Monitor return circuit and protection circuit and other occasions. For Armored Layer Cable, should be not less than 12 times of cable overall diameter. Plastic Insulated Control Cable is also provided. We has won the titles of Chinese Well-known Trademark and Nation.
For cable types, see Table
Type |
Name |
Main Scope for Use |
KVV |
Copper core, PVC insulated ,PVC sheathed control cable |
Laying indoor, in cable canals, pipelines, bridges and other fixed places |
KVVP |
Copper core, PVC insulated, PVC sheathed, braided and screened control cable |
Laying indoor, in cable canals, pipelines, bridges and other fixed places with screen requirement |
KVVP2 |
Copper core, PV insulated, PVC sheathed, copper belt screened control cable |
Laying indoor, in cable canals, pipelines, bridges and other fixed places with screen requirement |
KVV22 |
Copper core, PVC insulated, PVC sheathed soft control cable |
Laying indoor, in cable canals, pipelines, directburying, and other places able to bear relatively large outer mechanic force |
KVVR |
Copper core, PVC insulated, PVCsheathed soft control cable |
Laying indoor and other places requiring soft ones for movement |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
PVC Insulated Power Cable | Five-Core PVC Insulated Power Cable Product Standard Enterprise standard is used together with GB12706-2008. Usage PVC Sheathed Power Cableis suita... | |
ACSR Cable | AL Twiste Wireand ACSR Cable Product Standard GB/T 1179-2008, equivalent adoption of IEC61089-1997. Usage The product is suitable for overhead ... | |
PVC Sheathed Power Cable | Silane XLPE Insulated Power Cable Product Standard Enterprise standard: Equivalent to GB/T 12706-2008 and IEC 502-2004. Usage This product is suita... | |
Overhead Insulated Cable | Rated Voltage 1 KV And Below Overhead Insulated Cable Product Standard This product implements standard GB/T 12527-2008 Usage This product is suita... | |
Fire-Proof Wire and Cable Serial Products | Fire-Proof Wire and Cable Serial Products Product Standard Enterprise standard, this standard is equivalent to GB/T 19666-2005. Fire proof power ca... |