Fire Resistant Control Cable (2-4cores) 300-500V
Fire resistant control cable2-4 cores 300/500V features Mica tape twisted with copper conductor, the cable refers as multiple cores Cu/MicaXLPE(PVC)/LSZH 300/500V to basic standard BS7211. The function of mica is to prevent burning when cables catching fire. The cable can maintain the integrity of the electric circuit and continue to work for a period of time when exposed to fire. The sheath is compound material LSFH low smoking free holagen which has little smoking and no toxic gas emission which reduces the damage to the people and equipment. These fire rated control cables we supplied are twisted two layers of mica tape with 80% overlap rate which achieves a good performance of fire resistance.
Fire Resistant Control Cable (2-4cores) 300-500V Parameter
Conductor |
rated voltage 300/500v |
||||||
Without Earth Conductor |
With Earth Conductor |
||||||
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Nominal Overall Diameter |
||||
No*mm虏 |
mm |
mm |
mm |
kg/km |
mm |
kg/km |
|
2 Cores |
|||||||
7/0.53 |
70 |
80 |
|||||
7/0.67 |
100 |
120 |
|||||
2x4 |
7/0.85 |
140 |
170 |
||||
3 Cores |
|||||||
7/0.53 |
90 |
100 |
|||||
7/0.67 |
125 |
150 |
|||||
3x4 |
7/0.85 |
180 |
220 |
||||
4 Cores |
|||||||
7/0.53 |
105 |
120 |
|||||
7/0.67 |
11 |
155 |
13 |
190 |
|||
4x4 |
7/0.85 |
255 |
270 |
Description of Fire Resistant Control Cable(2-4cores) 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 times of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
NF C32-070-2.3(CR1) |
|
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE * |
|
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE |
|
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE ; |
CEI 20-37/2-1 ; BS 6425-1* |
|
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE ; |
CEI 20-37/2-2 ; BS 6425-2* |
|
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; |
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
|
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fireproof Electrical Cable(2-4cores) 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
As one of fire resistant cable suppliers, we can offer kinds of 2 core fire resistant cablefor sale, if you have needs, please contact us.
There are many flexible cable manufacturersin China, but we are one of the best choices for you.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
Bare Cable | Jenuincable supplies two main types of bare cable (bare conductor): soft drawn bare copper bare cable and hard drawn copper bare wire. Soft bare c... | |
Bare Cable | Jenuincable supplies two main types of bare cable(bare conductor): soft drawn bare copper bare wireand hard drawn copper bare cable. Soft bare ... | |
6242B 6243B LSZH Flat Cores +Earth Cable | As a China electric wire manufacturerand control cablesupplier with over 20 years of knowledge in the cables industry, we supply reliable cables wo... | |
BS EN 50525-2-11 | en 50525 cableapply to Electric cables — Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Part 2-11: Cable... | |
CU/LSZH/LSZH 6181B 6182B 6183B 6184B 6185B LSZH Multi Cores | Cu/LSZH/LSZH are the electric cables referred to thermosetting insulated and thermoplastic sheathed cables for voltage 450/750V electric power and ... |