Fire Resistant Control Cable (2-4cores) 300-500V
Fire resistant control cable2-4 cores 300/500V features Mica tape twisted with copper conductor, the cable refers as multiple cores Cu/MicaXLPE(PVC)/LSZH 300/500V to basic standard BS7211. The function of mica is to prevent burning when cables catching fire. The cable can maintain the integrity of the electric circuit and continue to work for a period of time when exposed to fire. The sheath is compound material LSFH low smoking free holagen which has little smoking and no toxic gas emission which reduces the damage to the people and equipment. These fire rated control cables we supplied are twisted two layers of mica tape with 80% overlap rate which achieves a good performance of fire resistance.
Fire Resistant Control Cable (2-4cores) 300-500V Parameter
Conductor |
rated voltage 300/500v |
||||||
Without Earth Conductor |
With Earth Conductor |
||||||
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Nominal Overall Diameter |
||||
No*mm虏 |
mm |
mm |
mm |
kg/km |
mm |
kg/km |
|
2 Cores |
|||||||
7/0.53 |
70 |
80 |
|||||
7/0.67 |
100 |
120 |
|||||
2x4 |
7/0.85 |
140 |
170 |
||||
3 Cores |
|||||||
7/0.53 |
90 |
100 |
|||||
7/0.67 |
125 |
150 |
|||||
3x4 |
7/0.85 |
180 |
220 |
||||
4 Cores |
|||||||
7/0.53 |
105 |
120 |
|||||
7/0.67 |
11 |
155 |
13 |
190 |
|||
4x4 |
7/0.85 |
255 |
270 |
Description of Fire Resistant Control Cable(2-4cores) 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 times of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
NF C32-070-2.3(CR1) |
|
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE * |
|
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE |
|
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE ; |
CEI 20-37/2-1 ; BS 6425-1* |
|
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE ; |
CEI 20-37/2-2 ; BS 6425-2* |
|
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; |
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
|
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fireproof Electrical Cable(2-4cores) 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
As one of fire resistant cable suppliers, we can offer kinds of 2 core fire resistant cablefor sale, if you have needs, please contact us.
There are many flexible cable manufacturersin China, but we are one of the best choices for you.
在线联系供应商
Other supplier products
CU/LSZH H07Z-U H07Z-R LSZH Building Wire | H07Z-U and h07z r cableare referred unsheath single-core cables insulated with halogen-free crosslinked compound and having low emission of smoke a... | |
6241B LSZH Single Cores +Earth Cable | Cu/LSZH/LSZH 6241b cableare the electric cables referred to thermosetting insulated and thermoplastic sheathed cables for voltage 300/500V electric... | |
CU/LSZH H05Z-U H05Z-R LSZH Building Wire | H05Z Uand H05Z-R cables are referred to 6491B nonsheath single core cables insulated with halogen-free crosslinked compound and having low emission... | |
CU/LSZH H05Z-U H05Z-R LSZH Building Wire | H05zand h07z ucables are referred to 6491B nonsheath single core cables insulated with halogen-free crosslinked compound and having low emission of... | |
BS 6004 | BS6004 cablerefers the Electric cables – PVC insulated and PVC sheathed cables for voltages up to and including 300/500 V, for electric power... |
Same products
YOU-IR2 Restore Easy Lightning Type-C 二合一 iPhone 恢复线 | 卖方: 深圳市维客修科技有限公司 | 描述 YOUKILOON YOU-IR2 恢复线带 Lightning Type-C 双接口,适用于 iPhone 6-16 Pro Max/iPad 快速恢复模式和数据传输。... | |
100% 原装 Lightning 转 USB 数据线 iPhone iPad 闪存恢复 | 卖方: 深圳市维客修科技有限公司 | 100% 原装 Apple 恢复线 iOS 自动 DFU 恢复线,适用于 iPhone/iPad 刷机和恢复工具。支持所有 iPad 和 iPhone 型号主板/逻辑板刷机和恢复。来自富士康工厂... | |
Mechanic Power Max/Ultra Anti-burning Boot Cable For iPhone Android | 卖方: 深圳市维客修科技有限公司 | Mechanic Power Ultra Boot Cable Features:1. Mechanic Power Ultra power cable suitable for Apple i... | |
Wylie Rear Camera Test Flex Cable for iPhone X-12 Pro Max | 卖方: Phonefix | Wylie rear back camera test extension flex cable for iPhone X-12 Pro Max. Wylie iPhone rear camer... | |
J-25 LONG WORKING LIFE RATCHETING CABLE CUTTER FOR CUTTING 150MM² STEEL WIRE AND 800MM² ACSR | 卖方: Zhejiang Huaqi Information Technology Co., LTD | The J25 Long Working Life Ratcheting Cable Cutter is a robust and durable tool engineered for cut... |