How to calculate the calorific value of transformer?
How to calculate the calorific value of transformer?
The calorific base of transformer = no load loss + load loss.
No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.
Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.
As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
XGN2 Type Modular High Voltage Switchgear,High Voltage Switchgear,High and Low Voltage Switchgears | XGN2 Type Modular High Voltage Switchgear,High Voltage Switchgear,High and Low Voltage Switchgears XGN2 type modular high-voltage switchgear cabine... | |
Why are transformers mostly used in parallel? | Transformer in the process of running has run in parallel and series operation, but are used in most of the use of parallel operation, parallel o... | |
non-encapsulated H-class dry-type power transformers | SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) dry-type transformers... | |
oil-immersed power transformers | The calorific base of transformer = no load loss + load loss. No-load loss: when the transformer secondary winding is open and the primary winding ... | |
SC(B)10 Series Resin-insulated Dry Type Transformer,cast resin transformer,dry-type transformer,cast resin dry transformer,step up dry transformer | SC(B)10 Series Resin-insulated Dry Type Transformer,cast resin transformer,dry-type transformer,cast resin dry transformer,step up dry transformer ... |
Похожие товары
Made in China Pressure Switch HC0622-24 for thermal power plant | Продавец: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD | "Made in China Pressure Switch HC0622-24 for thermal power plant YOYIK professional production an... | |
Gas Torch | Продавец: Ningbo Shuai Xian Regulator Co., Ltd | Introduction Set packed with hoses, regulator arm support of gas Torch Gas blow torchSpecific... | |
Gas Regulator Connector | Продавец: Ningbo Shuai Xian Regulator Co., Ltd | barbecue gas connectorused in conjunction with a cylinder valve to deliver an unreduced pressure ... | |
Gas Regulator Accessories, Gas Hose Fitting & Torch | Продавец: Ningbo Shuai Xian Regulator Co., Ltd | Integrated Gas Technologies(IGT®) supplies gas regulator outlet fittinglike gas regulator hos... | |
Gas Regulator | Продавец: Ningbo Shuai Xian Regulator Co., Ltd | Integrated Gas Technologies(IGT®) is a global gas control equipment company founded 2006 exce... |