How to calculate the calorific value of transformer?
How to calculate the calorific value of transformer?
The calorific base of transformer = no load loss + load loss.
No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.
Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.
As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.
Send product request
Other supplier products
cast resin transformer,dry-type transformer | Dry Type Transformer Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, easy to be installed, low o... | |
Principle of isolating transformer | The principle ofandis the same as that of ordinary transformer. All by electromagnetic induction. Isolation transformer generally refers to 380V/38... | |
How to calculate the calorific value of transformer? | How to calculate the calorific value of transformer? The calorific base of transformer = no load loss + load loss. No-load loss: when the transfo... | |
How to see the oil position of oil-immersed transformer? | oil-immersed transformeroil level gage to 30 °, + 20 ° and + 40 °, respectively is refers to the oil-immersed transformer at ambi... | |
Transformer Fault Reasons And Preventive Measures | Oill Transformer Manufacturertells us that operators should be familiar with the causes of transformer faults so that they can take timely treatm... |
Same products
BMR4612001/001 | Seller: 双为(香港)科技有限公司 | Product AttributeAttribute ValueSelect Attribute Manufacturer: Flex Product Catego... | |
R-785.0-0.5 | Seller: 双为(香港)科技有限公司 | Non-Isolated DC/DC Converters 0.5A DC/DC REG 6.5-34Vin 5Vout Product AttributeAttribute ... | |
OKL-T3-W12P-C | Seller: 双为(香港)科技有限公司 | Manufacturer: Murata Product Category: Non-Isolated DC/DC Converters Ro... | |
NMV0515SAC | Seller: 双为(香港)科技有限公司 | Manufacturer: Murata Product Category: Isolated DC/DC Converters - Through Hole ... | |
NKE0505DC DC/DC CONVERTERS | Seller: 双为(香港)科技有限公司 | Isolated DC/DC Converters - Through Hole 1W 5-5V DIP SINGLE DC/DC Manufacturer: Murat... |