GK600-CF Dedicated VFD For Hoist And Crane

GK600 Series Dedicated AC  Motor Drives for Hoist and Canes GK600-CFUser ManualFunction DescriptionGK600-CF Series mainly provides upstroke and downstroke contracting  brake for cranes. Different contracting brake logic functions can be set for  downstroke contracting brake parameters. The E0 group parameters are consistent  with GK600 General Purpose AC Motor Drives User Manual,Website:, describing upstroke  contracting brake functions. The F4 group is added as downstroke contracting  brake parameters.This supplementary user manual is required to be used together with GK600 Series  General Purpose AC Motor Drives User Manual.The F4 group of downstroke contracting brake parameters is added.Hardware  ModificationNoneList of ParametersParam.DesignationScopeFactory DefaultAttr.E0-05Contracting brake control0: Disabled1: Enabled0×E0-06Contracting brake release    frequency0.00Hz~10.00Hz2.50△E0-07Contracting brake release    current0.0%~200.0%120.0△E0-08Accel delay time after    contracting brake release0.0s~10.0s1.0△E0-09Contracting brake frequency0.00Hz~10.00Hz2.00△E0-10Contracting brake suction    waiting time0.0s~10.0s0.0△E0-11Contracting brake suction    holding time0.0s~10.0s1.0△Downstroke contracting brake    parametersF4-00Downstroke contracting brake    enabled0: Prohibited1: Enabled0×F4-01Downstroke direction0: Forward downstroke1: Reverse downstroke0△F4-02Downstroke contracting brake    release frequency0.00Hz~10.00Hz2.50△F4-03Downstroke contracting brake    release current0.0%~200.0%(Compared to the rated current of motor)120.0△F4-04Accel delay time after    downstroke contracting brake release0.0s~10.0s1.0△F4-05Downstroke contracting brake    frequency0.00Hz~10.00Hz2.00△F4-06Downstroke contracting brake    suction waiting time0.0s~10.0s0.0△F4-07Downstroke contracting brake    suction holding time0.0s~10.0s1.0△F4-08Downstroke contracting brake    release starting mode0: Started from starting frequency1: DC brake and then started 0△F4-09confirmation mode of contracting brake release0: Internal condition1: Confirmed by external terminal0△F4-10Current limit enabled0: Invalid according to current limit output frequency function1: Valid according to    current limit output frequency function0△F4-11Current limits running    frequency upper limit of threshold below0~600.00Hz50.00△F4-12Current limits running frequency    upper limit of threshold above0~600.00Hz45.00△F4-13Current limit threshold    percentage (Compared to the rated current of motor)0~200.0%30.0%×F4-14Current limit hysteresis    loop percentage (Compared to the rated current of motor)0~20.0%5.0%×F4-15Downstroke contracting brake    halt mode0: Decided by b1-131: DC braking stop0×F4-16Downstroke stop DC braking current0~200.0%100.0△F4-17Downstroke crease line    deceleration time switchover enabled0: Disabled1: Enabled0△F4-18Switchover frequency of    downstroke crease line deceleration time0~10.00Hz0△F4-19Downstroke contracting brake    release waiting time0~10.0s0△F4-20downstroke loosing brake DC braking current0~200.0%0△F4-21SP1 fault masking0: Not masking fault1: Mask SP1 fault0△F4-22Upstroke/downstroke    switchover repeatedly to check whether not contracting brake, and then loose    brake0: Need first contract brake and then loose brake1: Need first contract brake and then loose brake after entering the contracting brake area2: No need; right through0△F4-23Accel/decel time switchover    enabled at low frequency0: Prohibited accel/decel    time switchover at low frequency1: Enabled accel/decel time switchover at low frequency0△F4-24Switch over frequency at low    frequency0.00Hz~10.00Hz0.00△Detailed  Explanation of FunctionsE0  group parameters: Please refer to GK600 General Purpose AC Motor Drives User  Manual for upstroke contracting brake functions.F4 group:F4 -00Downstroke contracting     brake enabledScope: 0~1Factory     Default: 00: Prohibited  1:  Enabled  If 0 is  set, functions of contracting brake is the same as GK600 Series General Purpose  AC Motor DrivesF4 -01Downstroke directionScope: 0~1Factory     Default: 00: Forward is downstroke 1:  Reverse is downstrokeF4-02Downstroke contracting     brake release frequencyScope: 0.00Hz~10.00HzFactory     Default: 2.50To set contracting brake release frequency during downstrokeF4-03Downstroke contracting brake release current    Scope: 0.0%~200.0%Factory     Default: 120.0To set  the current limit of after loosing downstroke contracting brakeF4-04Accel delay time after downstroke contracting brake releaseScope: 0.0s~10.0sFactory Default: 1.0To set accel delay time after downstroke contracting brake releaseF4-05Downstroke contracting brake frequencyScope: 0.00Hz~10.00HzFactory Default: 2.00Valid  frequency of stop command lower than this setting value during downstroke,  contracting brake output signal is validF4-06Downstroke contracting brake suction waiting timeScope: 0.0s~10.0sFactory Default: 0.0When  stop command during downstroke is valid, contracting brake output signal is  valid when waiting for setting value time of this valueF4-07Downstroke contracting brake suction waiting timeScope: 0.0s~10.0sFactory Default: 1.0After contracting brake outputs, AC motor drives still have outputs during the waiting  time of suction.F4-08Downstroke contracting brake release starting modeScope: 0~1Factory Default: 00: Direct start  1: DC brake and then startedF4-09confirmation mode of contracting brake releaseScope: 0~1Factory Default: 00:  Internal condition  1:  Confirmed by external terminalF4-10Current limit enabledScope: 0~1Factory Default: 00:  Internal condition  1:  Confirmed by external terminalF4-11Running frequency of current limit threshold belowScope: 0~600.00HzFactory Default: 50.00F4-12Running frequency of current limit threshold aboveScope: 0~600.00HzFactory Default: 45.00F4-13Current limit threshold     percentageScope: 0~200.0%Factory     Default: 30.0F4-14Current limit hysteresis     loop percentageScope: 0~20.0%Factory     Default: 5.0F4-11~F4-14  limit output frequency when output current of AC motor drives is too largeF4-15Downstroke contracting brake halt modeScope: 0~1Factory Default: 00:  Decided by b1-131: DC braking stopF4-16Downstroke stop DC braking currentScope: 0~200.0%Factory Default:     100.0Use as  DC brake during downstroke contracting brake, to improve the comfortability  during contracting brakeF4-17Downstroke crease line deceleration time switchover enabledScope: 0~1Factory     Default: 00:  Prohibited  1:  EnabledF4-18Switchover frequency of downstroke crease line deceleration timeScope: 0~10.00HzFactory     Default: 0.00According to F4-18 setting value, when 1 is set in F4-17, decel time is shortened when  lower than this setting value.F4-19Downstroke contracting brake release waiting timeScope: 0~10.0sFactory Default: 0.0To set downstroke contracting brake release waiting timeF4-20downstroke loosing brake DC braking currentScope: 0~200.0%Factory     Default: 0.0Start  DC brake current during downstroke loosing brakeF4-21SP1 fault maskingScope: 0~1Factory     Default: 00:  Prohibited  1:  EnabledF4-22Upstroke/downstroke switchover repeatedly to check whether not contracting brake, and then loose brakeScope: 0~2Factory Default: 00: Need  first contract brake and then loose brake  1: Need  first contract brake and then loose brake after entering the contracting brake  area  2: No  need; right throughF4-23Accel/decel time switchover enabled at low frequencyScope: 0~1Factory Default: 0F4-24Switch over frequency at low frequencyScope: 0.00~10.00HzFactory Default: 0.00F4-230:  Prohibited accel/decel time switchover at low frequency1:  Enabled accel/decel time switchover at low frequencyF4-24Threshold  limit setting value at low frequencyAdd  input and output terminal functions:Input  terminal:C0-01  C0-02  ……..  C0-10Input terminal selection82: Loose brake input0~99Other functions are the same as GK600 standard  software.For detailed quotation and other questions,  please contact us directly.


Отправить запрос, связаться с поставщиком

Кому: Jiangsu GTAKE Electric Co., Ltd
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

GK800-2T90 Strong Overload Capacity AC Drives,Website:, Vector-controlled AC Motor Drives
GK800 Closed-loop Vector Control Variable Speed DriveGK800 Series High Performance Variable Speed Drives,Website:, adopting most advanced close-loo...
GK1000 AFE Energy Feedback AC DrivesGK1000 provides active front end (Active Front End,Website:, hereinafter referred to as AFE) function. Active f...
GK500 Mini Series Variable Frequency Drives (0.4kW-3.7kW)GK500 Series Mini V/Hz Control Variable Frequency Drives are specialized for low power (0....
GK800 Closed-loop Vector Control VFD Drives GK800 Series High Performance VFD Drives,Website:, adopting most advanced close-loop vector ...
Все товары поставщика

Похожие товары

Rated Power 2400W 24VDC Solar Inverter
Rated Power 2400W 24VDC Solar Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24VDC Solar Inverter The DC 2.4 kw inverterwith a rated power of 2400 watts is...
Rated Power 2400W 24VDC PV Inverter
Rated Power 2400W 24VDC PV Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24VDC PV Inverter This is a single phase inverter rated at 2400 watts, 24 volt...
Rated Power 2400W 24VDC Pure Sine Wave Solar Inverter
Rated Power 2400W 24VDC Pure Sine Wave Solar Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24 Volt Pure Sine Wave Inverter It is a new generation of power inverter with ...
Rated Power 2400W 24VDC Off Grid Solar Inverter
Rated Power 2400W 24VDC Off Grid Solar Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24VDC Off Grid Solar Inverter This is a cost-effective solar inverter that acc...
Rated Power 2400W 24VDC Battery Inverter
Rated Power 2400W 24VDC Battery Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24VDC Battery Inverter The Rated Power 2400W 24VDC Battery Inverter is a mid-r...