GK600-CF Dedicated VFD For Hoist And Crane
GK600 Series Dedicated AC Motor Drives for Hoist and Canes GK600-CFUser ManualFunction DescriptionGK600-CF Series mainly provides upstroke and downstroke contracting brake for cranes. Different contracting brake logic functions can be set for downstroke contracting brake parameters. The E0 group parameters are consistent with GK600 General Purpose AC Motor Drives User Manual,Website:, describing upstroke contracting brake functions. The F4 group is added as downstroke contracting brake parameters.This supplementary user manual is required to be used together with GK600 Series General Purpose AC Motor Drives User Manual.The F4 group of downstroke contracting brake parameters is added.Hardware ModificationNoneList of ParametersParam.DesignationScopeFactory DefaultAttr.E0-05Contracting brake control0: Disabled1: Enabled0×E0-06Contracting brake release frequency0.00Hz~10.00Hz2.50△E0-07Contracting brake release current0.0%~200.0%120.0△E0-08Accel delay time after contracting brake release0.0s~10.0s1.0△E0-09Contracting brake frequency0.00Hz~10.00Hz2.00△E0-10Contracting brake suction waiting time0.0s~10.0s0.0△E0-11Contracting brake suction holding time0.0s~10.0s1.0△Downstroke contracting brake parametersF4-00Downstroke contracting brake enabled0: Prohibited1: Enabled0×F4-01Downstroke direction0: Forward downstroke1: Reverse downstroke0△F4-02Downstroke contracting brake release frequency0.00Hz~10.00Hz2.50△F4-03Downstroke contracting brake release current0.0%~200.0%(Compared to the rated current of motor)120.0△F4-04Accel delay time after downstroke contracting brake release0.0s~10.0s1.0△F4-05Downstroke contracting brake frequency0.00Hz~10.00Hz2.00△F4-06Downstroke contracting brake suction waiting time0.0s~10.0s0.0△F4-07Downstroke contracting brake suction holding time0.0s~10.0s1.0△F4-08Downstroke contracting brake release starting mode0: Started from starting frequency1: DC brake and then started 0△F4-09confirmation mode of contracting brake release0: Internal condition1: Confirmed by external terminal0△F4-10Current limit enabled0: Invalid according to current limit output frequency function1: Valid according to current limit output frequency function0△F4-11Current limits running frequency upper limit of threshold below0~600.00Hz50.00△F4-12Current limits running frequency upper limit of threshold above0~600.00Hz45.00△F4-13Current limit threshold percentage (Compared to the rated current of motor)0~200.0%30.0%×F4-14Current limit hysteresis loop percentage (Compared to the rated current of motor)0~20.0%5.0%×F4-15Downstroke contracting brake halt mode0: Decided by b1-131: DC braking stop0×F4-16Downstroke stop DC braking current0~200.0%100.0△F4-17Downstroke crease line deceleration time switchover enabled0: Disabled1: Enabled0△F4-18Switchover frequency of downstroke crease line deceleration time0~10.00Hz0△F4-19Downstroke contracting brake release waiting time0~10.0s0△F4-20downstroke loosing brake DC braking current0~200.0%0△F4-21SP1 fault masking0: Not masking fault1: Mask SP1 fault0△F4-22Upstroke/downstroke switchover repeatedly to check whether not contracting brake, and then loose brake0: Need first contract brake and then loose brake1: Need first contract brake and then loose brake after entering the contracting brake area2: No need; right through0△F4-23Accel/decel time switchover enabled at low frequency0: Prohibited accel/decel time switchover at low frequency1: Enabled accel/decel time switchover at low frequency0△F4-24Switch over frequency at low frequency0.00Hz~10.00Hz0.00△Detailed Explanation of FunctionsE0 group parameters: Please refer to GK600 General Purpose AC Motor Drives User Manual for upstroke contracting brake functions.F4 group:F4 -00Downstroke contracting brake enabledScope: 0~1Factory Default: 00: Prohibited
1: Enabled
If 0 is set, functions of contracting brake is the same as GK600 Series General Purpose AC Motor DrivesF4 -01Downstroke directionScope: 0~1Factory Default: 00: Forward is downstroke
1: Reverse is downstrokeF4-02Downstroke contracting brake release frequencyScope: 0.00Hz~10.00HzFactory Default: 2.50To set contracting brake release frequency during downstrokeF4-03Downstroke contracting brake release current Scope: 0.0%~200.0%Factory Default: 120.0To set the current limit of after loosing downstroke contracting brakeF4-04Accel delay time after downstroke contracting brake releaseScope: 0.0s~10.0sFactory Default: 1.0To set accel delay time after downstroke contracting brake releaseF4-05Downstroke contracting brake frequencyScope: 0.00Hz~10.00HzFactory Default: 2.00Valid frequency of stop command lower than this setting value during downstroke, contracting brake output signal is validF4-06Downstroke contracting brake suction waiting timeScope: 0.0s~10.0sFactory Default: 0.0When stop command during downstroke is valid, contracting brake output signal is valid when waiting for setting value time of this valueF4-07Downstroke contracting brake suction waiting timeScope: 0.0s~10.0sFactory Default: 1.0After contracting brake outputs, AC motor drives still have outputs during the waiting time of suction.F4-08Downstroke contracting brake release starting modeScope: 0~1Factory Default: 00: Direct start
1: DC brake and then startedF4-09confirmation mode of contracting brake releaseScope: 0~1Factory Default: 00: Internal condition
1: Confirmed by external terminalF4-10Current limit enabledScope: 0~1Factory Default: 00: Internal condition
1: Confirmed by external terminalF4-11Running frequency of current limit threshold belowScope: 0~600.00HzFactory Default: 50.00F4-12Running frequency of current limit threshold aboveScope: 0~600.00HzFactory Default: 45.00F4-13Current limit threshold percentageScope: 0~200.0%Factory Default: 30.0F4-14Current limit hysteresis loop percentageScope: 0~20.0%Factory Default: 5.0F4-11~F4-14 limit output frequency when output current of AC motor drives is too largeF4-15Downstroke contracting brake halt modeScope: 0~1Factory Default: 00: Decided by b1-131: DC braking stopF4-16Downstroke stop DC braking currentScope: 0~200.0%Factory Default: 100.0Use as DC brake during downstroke contracting brake, to improve the comfortability during contracting brakeF4-17Downstroke crease line deceleration time switchover enabledScope: 0~1Factory Default: 00: Prohibited
1: EnabledF4-18Switchover frequency of downstroke crease line deceleration timeScope: 0~10.00HzFactory Default: 0.00According to F4-18 setting value, when 1 is set in F4-17, decel time is shortened when lower than this setting value.F4-19Downstroke contracting brake release waiting timeScope: 0~10.0sFactory Default: 0.0To set downstroke contracting brake release waiting timeF4-20downstroke loosing brake DC braking currentScope: 0~200.0%Factory Default: 0.0Start DC brake current during downstroke loosing brakeF4-21SP1 fault maskingScope: 0~1Factory Default: 00: Prohibited
1: EnabledF4-22Upstroke/downstroke switchover repeatedly to check whether not contracting brake, and then loose brakeScope: 0~2Factory Default: 00: Need first contract brake and then loose brake
1: Need first contract brake and then loose brake after entering the contracting brake area
2: No need; right throughF4-23Accel/decel time switchover enabled at low frequencyScope: 0~1Factory Default: 0F4-24Switch over frequency at low frequencyScope: 0.00~10.00HzFactory Default: 0.00F4-230: Prohibited accel/decel time switchover at low frequency1: Enabled accel/decel time switchover at low frequencyF4-24Threshold limit setting value at low frequencyAdd input and output terminal functions:Input terminal:C0-01 C0-02 …….. C0-10Input terminal selection82: Loose brake input0~99Other functions are the same as GK600 standard software.For detailed quotation and other questions, please contact us directly.