What is the Line Voltage and Phase Voltage of the Transformer?

The transformer such asOil Immersed Transformeris a kind of voltage that can stabilize the voltage in the circuit and ensure the stability of the voltage and current in the circuit. For the transformer, it is a kind of electric equipment, which plays a huge role in various circuits and various kinds of circuits. A variety of advantages. Transformers have their own voltage and current. There are two kinds of transformers on the voltage, one is the line voltage and the phase voltage. They are two different voltages in a transformer. They are related and different. So what is the relationship between them?

The line voltage is the phase voltage of 3 times the root number, which is the voltage between the hot lines.

The phase voltage is the voltage between each phase and the neutral line. It is the voltage between each live line and the neutral line.

The line voltage refers to the voltage from the lead line of theThree Phase Transformer. The phase current refers to the current flowing through a phase coil of the three-phase equipment, and the phase voltage is the voltage applied to a separate set of coils. The phase voltage is the voltage between the phase line and the neutral line. For the delta connection, the line voltage is equal to the phase voltage, and the line current is equal to 3 times the root of the phase current; for the star connection, the line current is equal to the phase current, and the line voltage is equal to 3 times the root of the phase voltage. For practical three-phase equipment, such as transformers, motors, etc., measuring line current line voltage is easier to implement than measuring phase current phase voltage, so the nameplate is marked with line current and line voltage.

Transformer secondary side load current: line current = phase current, line voltage between three phases, phase and voltage of any phase of the three phases.

In the symmetrical three-phase circuit, the phase voltage or the line voltage can be used for calculation, but the formula is different.

Use the line voltage calculation formula:

P=1.732×U×I

Use the phase voltage calculation formula:

P=3×U×I

The introduction of the two voltages of the transformer and the related calculation methods will be introduced here. For the two voltages of the transformer, the functions and various advantages should be exerted to a greater extent to ensure the stability of the transformer voltage and achieve transformer safety. And stable operation!

The company mainly produces: , dry-type transformers, box-type substation, and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

If you want to know more about the product, please.

MoreProductsPlease View.



Отправить запрос, связаться с поставщиком

Кому: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Fixed mounted Switchgear
Fixed mounted Switchgear Low Voltage Switchgear High and Low Voltage Switchgears GGD series low voltage switchgearis used for power lighting Product Description GGD series ...
oil-immersed power transformers
oil-immersed power transformers The calorific base of transformer = no load loss + load loss. No-load loss: when the transformer secondary winding is open and the primary winding ...
Characteristics and properties of amorphous alloy transformer
Characteristics and properties of amorphous alloy transformer Characteristics and properties of amorphous alloy transformer is a new type of energy saving transformer made of a new magnetic conducting material...
шаг до сухих трансформаторов
шаг до сухих трансформаторов шаг до сухих трансформаторов Сухой Тип Трансформатор Пламя-retardant, non-загрязнения, он может быть установлен непосредственно в центре нагрузок. ...
How To Sample Transformer Oil?
How To Sample Transformer Oil? The method and process of takingTransformer Oilsamples are as follows: (1) sampling of transformer oil is necessary for the test of transformer oi...
Все товары поставщика

Похожие товары

ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane...
ACREL DTSD1352-C SOLAR INVERTER SMART METER
ACREL DTSD1352-C SOLAR INVERTER SMART METER Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. Acrel sungrow smart meterDTSD1352 din rail type multi-function energy meter is an intelligent ins...