What is the Line Voltage and Phase Voltage of the Transformer?

The transformer such asOil Immersed Transformeris a kind of voltage that can stabilize the voltage in the circuit and ensure the stability of the voltage and current in the circuit. For the transformer, it is a kind of electric equipment, which plays a huge role in various circuits and various kinds of circuits. A variety of advantages. Transformers have their own voltage and current. There are two kinds of transformers on the voltage, one is the line voltage and the phase voltage. They are two different voltages in a transformer. They are related and different. So what is the relationship between them?

The line voltage is the phase voltage of 3 times the root number, which is the voltage between the hot lines.

The phase voltage is the voltage between each phase and the neutral line. It is the voltage between each live line and the neutral line.

The line voltage refers to the voltage from the lead line of theThree Phase Transformer. The phase current refers to the current flowing through a phase coil of the three-phase equipment, and the phase voltage is the voltage applied to a separate set of coils. The phase voltage is the voltage between the phase line and the neutral line. For the delta connection, the line voltage is equal to the phase voltage, and the line current is equal to 3 times the root of the phase current; for the star connection, the line current is equal to the phase current, and the line voltage is equal to 3 times the root of the phase voltage. For practical three-phase equipment, such as transformers, motors, etc., measuring line current line voltage is easier to implement than measuring phase current phase voltage, so the nameplate is marked with line current and line voltage.

Transformer secondary side load current: line current = phase current, line voltage between three phases, phase and voltage of any phase of the three phases.

In the symmetrical three-phase circuit, the phase voltage or the line voltage can be used for calculation, but the formula is different.

Use the line voltage calculation formula:

P=1.732×U×I

Use the phase voltage calculation formula:

P=3×U×I

The introduction of the two voltages of the transformer and the related calculation methods will be introduced here. For the two voltages of the transformer, the functions and various advantages should be exerted to a greater extent to ensure the stability of the transformer voltage and achieve transformer safety. And stable operation!

The company mainly produces: , dry-type transformers, box-type substation, and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.

If you want to know more about the product, please.

MoreProductsPlease View.


在线联系供应商

至: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Transformer Fault Reasons And Preventive Measures
Transformer Fault Reasons And Preventive Measures Oill Transformer Manufacturertells us that operators should be familiar with the causes of transformer faults so that they can take timely treatm...
Transformer Energy Saving is More and More Popularized
Transformer Energy Saving is More and More Popularized Transformers such asThree Phase Transformeralso have great developments and changes in the development experience, and the process of transformer ...
Do You Know What Is The Short Circuit Impedance of The Transformer?
Do You Know What Is The Short Circuit Impedance of The Transformer? process of using, it is necessary to enhance the continuous improvement of the use and efficiency of the transformer such asDry Type Transformer....
Cooling Method of Oil Immersed Power Transformer
Cooling Method of Oil Immersed Power Transformer In the operation of theOil Immersed Power Transformer, the heat of the winding and the iron core is first transmitted to the oil and then transmit...
How to see the oil position of oil-immersed transformer?
How to see the oil position of oil-immersed transformer? oil-immersed transformeroil level gage to 30 °, + 20 ° and + 40 °, respectively is refers to the oil-immersed transformer at ambi...
供应产品

Same products

China factory Transformer bushing BRDW-126/630-3 for power station
China factory Transformer bushing BRDW-126/630-3 for power station 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel...
TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER 卖方: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...