non-encapsulated H-class dry-type power transformers
SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) dry-type transformers to ensure that the products fully meet the requirements such as fire prevention, waterproof ,environmental protection. It is the ideal product for distribution systems and widely used in the subway, shipbuilding, mining, chemical, power companies and personnel-intensive buildings as well as other special requirements of the occasion for safety.
Model and Meaning
SC(B)10 Series Resin-insulated Dry Type Transformer
SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers
Technical Parameter for6kV, 10kV& 30kVA-2500kVA With Off Circuit Dry Type Transformer
Rated capacity(KVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
30 |
±2X2.5%±5% |
Dyn11Yyn0 |
190 |
670 |
710 |
760 |
||||
50 |
270 |
940 |
1000 |
1070 |
||||||
80 |
370 |
1290 |
1380 |
1480 |
||||||
100 |
400 |
1480 |
1570 |
1690 |
||||||
125 |
470 |
1740 |
1850 |
1980 |
||||||
160 |
540 |
2000 |
2130 |
2280 |
||||||
200 |
±2X2.5%±5% |
620 |
2370 |
2530 |
2710 |
|||||
250 |
720 |
2590 |
2760 |
2960 |
||||||
315 |
880 |
3270 |
3470 |
3730 |
||||||
400 |
980 |
3750 |
3990 |
4280 |
||||||
500 |
1150 |
4590 |
4880 |
5230 |
||||||
630 |
1340 |
5530 |
5880 |
6290 |
||||||
630 |
1300 |
5610 |
5960 |
6400 |
||||||
800 |
1520 |
6550 |
6960 |
7460 |
||||||
1000 |
1770 |
7650 |
8130 |
8760 |
||||||
1250 |
2090 |
9100 |
9690 |
10300 |
||||||
1600 |
2450 |
11000 |
11700 |
12500 |
||||||
2000 |
3050 |
13600 |
14400 |
15500 |
||||||
2500 |
3600 |
16100 |
17100 |
18400 |
||||||
1600 |
2450 |
1220 |
12900 |
13900 |
||||||
2000 |
3050 |
15000 |
15900 |
17100 |
||||||
2500 |
3600 |
17700 |
18800 |
20200 |
Notes:The load losses listed in the table are the values of the reference temperature for different insulation systems inparentheses; The load losses under other insulation system temperatures that are not included in the table should be according to their respective reference temperatures, the corresponding calculation is based on the"- 155 ℃(F)" insulation system temperature data.
Notes:The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
Technical Parameter for20kV& 50kVA-2500kVA With Off CircuitDry Type Transformer
(KVA)Rated capacity |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
50 |
202224 |
±2.5%±5%±5%±2×2.5% |
Dyn11Yyn0 |
340 |
1160 |
1230 |
1310 |
|||
100 |
540 |
1870 |
1990 |
2130 |
||||||
160 |
2350 |
2470 |
3460 |
|||||||
200 |
±2X2.5%±5% |
730 |
2770 |
2940 |
3140 |
|||||
250 |
840 |
3220 |
3420 |
3660 |
||||||
315 |
970 |
3850 |
4080 |
4360 |
||||||
400 |
1150 |
4650 |
4840 |
5180 |
||||||
500 |
1350 |
5460 |
5790 |
6190 |
||||||
630 |
1530 |
6450 |
6840 |
7320 |
||||||
800 |
1750 |
7790 |
8260 |
8840 |
||||||
1000 |
2070 |
9220 |
9780 |
10400 |
||||||
1250 |
2380 |
10800 |
11500 |
12300 |
||||||
1600 |
2790 |
13000 |
13800 |
14800 |
||||||
2000 |
3240 |
15400 |
16300 |
17500 |
||||||
2500 |
18200 |
19300 |
20700 |
|||||||
2000 |
3240 |
16800 |
17800 |
19100 |
||||||
2500 |
3870 |
20000 |
21200 |
22700 |
Technical Parameter for35kV& 50kVA-2500kVA With Off CircuitDry Type Transformer
(KVA)Rated capacity |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
50 |
±2.5%±5%±5%±2×2.5% |
Dyn11Yyn0 |
450 |
1340 |
1420 |
1520 |
||||
100 |
630 |
1970 |
2090 |
2230 |
||||||
160 |
2650 |
2810 |
3000 |
|||||||
200 |
±2X2.5%±5% |
3130 |
3320 |
3550 |
||||||
250 |
3580 |
3800 |
4060 |
|||||||
315 |
1170 |
4250 |
4510 |
4820 |
||||||
400 |
1370 |
5100 |
5410 |
5790 |
||||||
500 |
1520 |
6270 |
6650 |
7110 |
||||||
630 |
1860 |
7250 |
7690 |
8230 |
||||||
800 |
2160 |
8600 |
9120 |
9760 |
||||||
1000 |
2430 |
9860 |
10400 |
11100 |
||||||
1250 |
2830 |
12000 |
12700 |
13600 |
||||||
1600 |
3240 |
14600 |
15400 |
16500 |
||||||
2000 |
3820 |
17200 |
18200 |
19500 |
||||||
2500 |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
Working principle of transformer | Three phase transformer Manufacturershares that transformer is a kind of electric appliance that transfers electric energy or transmits signal fr... | |
How to calculate the calorific value of transformer? | How to calculate the calorific value of transformer? The calorific base of transformer = no load loss + load loss. No-load loss: when the transfo... | |
cast resin transformer,dry-type transformer | Dry Type Transformer Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, easy to be installed, low o... | |
Oil filled power transformer | Transformer is an important electrical equipment that must be used in our production and life. For transformer, it can control the voltage and cur... | |
GCK Low-voltage Draw out Switchgear,Low Voltage Switchgear,Draw out Switchgear,Circuit Breaker Switchgear | GCK Low-voltage Draw out Switchgear,Low Voltage Switchgear,Draw out Switchgear,Circuit Breaker Switchgear High and Low Voltage Switchgears GCK se... |
Похожие товары
ACREL AID150 ALARM AND DISPLAY DEVICE | Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
ACREL ANSVG STATIC VAR GENERATOR | Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
The Working Principle of Active Power Filter | Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... | |
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER | Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. | PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane... | |
ACREL DTSD1352-C SOLAR INVERTER SMART METER | Продавец: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Acrel sungrow smart meterDTSD1352 din rail type multi-function energy meter is an intelligent ins... |