non-encapsulated H-class dry-type power transformers
SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) dry-type transformers to ensure that the products fully meet the requirements such as fire prevention, waterproof ,environmental protection. It is the ideal product for distribution systems and widely used in the subway, shipbuilding, mining, chemical, power companies and personnel-intensive buildings as well as other special requirements of the occasion for safety.
Model and Meaning
SC(B)10 Series Resin-insulated Dry Type Transformer
SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers
Technical Parameter for6kV, 10kV& 30kVA-2500kVA With Off Circuit Dry Type Transformer
|
Rated capacity(KVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
|
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
|
30 |
±2X2.5%±5% |
Dyn11Yyn0 |
190 |
670 |
710 |
760 |
||||
|
50 |
270 |
940 |
1000 |
1070 |
||||||
|
80 |
370 |
1290 |
1380 |
1480 |
||||||
|
100 |
400 |
1480 |
1570 |
1690 |
||||||
|
125 |
470 |
1740 |
1850 |
1980 |
||||||
|
160 |
540 |
2000 |
2130 |
2280 |
||||||
|
200 |
±2X2.5%±5% |
620 |
2370 |
2530 |
2710 |
|||||
|
250 |
720 |
2590 |
2760 |
2960 |
||||||
|
315 |
880 |
3270 |
3470 |
3730 |
||||||
|
400 |
980 |
3750 |
3990 |
4280 |
||||||
|
500 |
1150 |
4590 |
4880 |
5230 |
||||||
|
630 |
1340 |
5530 |
5880 |
6290 |
||||||
|
630 |
1300 |
5610 |
5960 |
6400 |
||||||
|
800 |
1520 |
6550 |
6960 |
7460 |
||||||
|
1000 |
1770 |
7650 |
8130 |
8760 |
||||||
|
1250 |
2090 |
9100 |
9690 |
10300 |
||||||
|
1600 |
2450 |
11000 |
11700 |
12500 |
||||||
|
2000 |
3050 |
13600 |
14400 |
15500 |
||||||
|
2500 |
3600 |
16100 |
17100 |
18400 |
||||||
|
1600 |
2450 |
1220 |
12900 |
13900 |
||||||
|
2000 |
3050 |
15000 |
15900 |
17100 |
||||||
|
2500 |
3600 |
17700 |
18800 |
20200 |
||||||
Notes:The load losses listed in the table are the values of the reference temperature for different insulation systems inparentheses; The load losses under other insulation system temperatures that are not included in the table should be according to their respective reference temperatures, the corresponding calculation is based on the"- 155 ℃(F)" insulation system temperature data.
Notes:The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
Technical Parameter for20kV& 50kVA-2500kVA With Off CircuitDry Type Transformer
|
(KVA)Rated capacity |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
|
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
|
50 |
202224 |
±2.5%±5%±5%±2×2.5% |
Dyn11Yyn0 |
340 |
1160 |
1230 |
1310 |
|||
|
100 |
540 |
1870 |
1990 |
2130 |
||||||
|
160 |
2350 |
2470 |
3460 |
|||||||
|
200 |
±2X2.5%±5% |
730 |
2770 |
2940 |
3140 |
|||||
|
250 |
840 |
3220 |
3420 |
3660 |
||||||
|
315 |
970 |
3850 |
4080 |
4360 |
||||||
|
400 |
1150 |
4650 |
4840 |
5180 |
||||||
|
500 |
1350 |
5460 |
5790 |
6190 |
||||||
|
630 |
1530 |
6450 |
6840 |
7320 |
||||||
|
800 |
1750 |
7790 |
8260 |
8840 |
||||||
|
1000 |
2070 |
9220 |
9780 |
10400 |
||||||
|
1250 |
2380 |
10800 |
11500 |
12300 |
||||||
|
1600 |
2790 |
13000 |
13800 |
14800 |
||||||
|
2000 |
3240 |
15400 |
16300 |
17500 |
||||||
|
2500 |
18200 |
19300 |
20700 |
|||||||
|
2000 |
3240 |
16800 |
17800 |
19100 |
||||||
|
2500 |
3870 |
20000 |
21200 |
22700 |
||||||
Technical Parameter for35kV& 50kVA-2500kVA With Off CircuitDry Type Transformer
|
(KVA)Rated capacity |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
|
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
|
50 |
±2.5%±5%±5%±2×2.5% |
Dyn11Yyn0 |
450 |
1340 |
1420 |
1520 |
||||
|
100 |
630 |
1970 |
2090 |
2230 |
||||||
|
160 |
2650 |
2810 |
3000 |
|||||||
|
200 |
±2X2.5%±5% |
3130 |
3320 |
3550 |
||||||
|
250 |
3580 |
3800 |
4060 |
|||||||
|
315 |
1170 |
4250 |
4510 |
4820 |
||||||
|
400 |
1370 |
5100 |
5410 |
5790 |
||||||
|
500 |
1520 |
6270 |
6650 |
7110 |
||||||
|
630 |
1860 |
7250 |
7690 |
8230 |
||||||
|
800 |
2160 |
8600 |
9120 |
9760 |
||||||
|
1000 |
2430 |
9860 |
10400 |
11100 |
||||||
|
1250 |
2830 |
12000 |
12700 |
13600 |
||||||
|
1600 |
3240 |
14600 |
15400 |
16500 |
||||||
|
2000 |
3820 |
17200 |
18200 |
19500 |
||||||
|
2500 |
||||||||||
Send product request
Other supplier products
| mobile transformer substation | ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 “high and low voltage prefabricated substation” a... | |
| Cooling Method of Oil Immersed Power Transformer | In the operation of theOil Immersed Power Transformer, the heat of the winding and the iron core is first transmitted to the oil and then transmit... | |
| What is the Line Voltage and Phase Voltage of the Transformer? | The transformer such asOil Immersed Transformeris a kind of voltage that can stabilize the voltage in the circuit and ensure the stability of the ... | |
| Why are transformers mostly used in parallel? | Transformer in the process of running has run in parallel and series operation, but are used in most of the use of parallel operation, parallel o... | |
| [Transformers for sale]How can oil-immersed transformers reduce copper loss? | How can the copper loss of transformer be reduced in long - term operation? Shared byoil immersed transformer supplier. That's all for the sharing... |
Same products
| China factory Transformer bushing BRDW-126/630-3 for power station | Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD | "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel... | |
| TOROIDAL TRANSFORMER | Seller: Yu Yang Magnetic Co., LTD | Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >... | |
| ACREL AID150 ALARM AND DISPLAY DEVICE | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
| ACREL ANSVG STATIC VAR GENERATOR | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
| The Working Principle of Active Power Filter | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... |








![[Transformers for sale]How can oil-immersed transformers reduce copper loss?](/images/products/products_789051_09277eea52da837be986888826aef988.jpeg)