P3 Or P3/P10 RFOU/TFOU 6/10KV NEK606 Cable

P3 or P3/P10 RFOU/TFOU 6/10KV NEK606 MV CableApplicationsThese cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.StandardsIEC 60092-354; IEC 60092-351; IEC 60092-359; IEC 60332-1; IEC 60332-3-22; IEC 60754-1,2; IEC 61034-1,2; NEK 606:2004ConductorsCircular tinned annealed stranded copper to IEC 60228 class 2.Conductor ScreenSemi conducting material.InsulationHalogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation ScreenSemi conducting material and tinned copper wire braid.BeddingHalogen free compound.ArmourTinned copper wire braid.Outer SheathHalogen free thermosetting compound, SHF2 (for TYPE P3), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P3/P10),coloured red.Electrical CharacteristicsNominal Cross Section Areamm²Nominal Conductor Diametermm5.26.57.48.710.312.213.8Maximum DC Current Rating@45℃1 CoreAContinuous Current Rating@45℃3 CoreAShort Circuit Current 1sAOperating VoltageKV6/106/106/106/106/106/106/10Nominal Cross Section Areamm²Nominal Conductor Diametermm15.117.019.621.924.527.532.3Maximum DC Current Rating@45℃1 CoreAContinuous Current Rating@45℃3 CoreAShort Circuit Current 1sAOperating VoltageKV6/106/106/106/106/106/106/10Ambient Temperature Correction FactorsAmbient Temperature Correction FactorsRating Factor1.11.051.00.940.880.820.740.670.580.47Mechanical and Thermal PropertiesBending Radius 15×OD (during installation); 9×OD (fixed installed).Temperature Range -20℃ ~ +90℃.Dimensions and WeightConstruction No. of cores×Cross section(mm2)Nominal Insulation ThicknessmmNominal Sheath ThicknessmmNominal Overall DiametermmNominal Weightkg/kmInnerOuter1×163.41.51.124.09001×253.41.51.226.011401×353.41.61.226.912651×503.41.61.228.314601×703.41.71.330.017101×953.41.81.332.020601×1203.41.81.433.823801×1503.41.91.435.327001×1853.42.01.537.832251×2403.42.11.641.039901×3003.42.21.643.747601×4003.42.31.745.559001×5003.42.41.849.573501×6303.42.61.954.587503×163.42.31.746.033003×253.42.41.850.139053×353.42.51.852.243603×503.42.61.955.151853×703.42.72.058.961253×953.42.92.163.575003×1203.43.02.267.687753×1503.43.22.371.7102353×1853.43.42.474.0113003×2403.43.62.679.5133003×3003.43.82.785.016300
Другие товары поставщика
|
|
|
UL Industrial Cables USE-2Application and DescriptionThe product can be installed as general purpose building wire,Website:, used in service entran... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multipair)RE-2Y(St)HSWAH 90°C / 300VSTANDARDSBasic desig... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8345ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
0.6/1 kV Mica Tape + XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Fire Resistant Power & Control Cables (Multicore)ApplicationThese armo... |
|
|
|
300/500V SR Insulated & LSZH Sheathed Fire Alarm CablesFR200P 2GSH-U (PH30) (CU/SR/OS/LSZH 300/500V Class 1)FR200P 2GSH-R (PH30) (CU/SR/OS/LSZH 300... |
Все товары поставщика
Похожие товары
|
|
PMMA VR Lens For Google Cardboard |
Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |