P3 Or P3/P10 RFOU/TFOU 6/10KV NEK606 Cable

P3 or P3/P10 RFOU/TFOU 6/10KV NEK606 MV CableApplicationsThese cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.StandardsIEC 60092-354; IEC 60092-351; IEC 60092-359; IEC 60332-1; IEC 60332-3-22; IEC 60754-1,2; IEC 61034-1,2; NEK 606:2004ConductorsCircular tinned annealed stranded copper to IEC 60228 class 2.Conductor ScreenSemi conducting material.InsulationHalogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation ScreenSemi conducting material and tinned copper wire braid.BeddingHalogen free compound.ArmourTinned copper wire braid.Outer SheathHalogen free thermosetting compound, SHF2 (for TYPE P3), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P3/P10),coloured red.Electrical CharacteristicsNominal Cross Section Areamm²Nominal Conductor Diametermm5.26.57.48.710.312.213.8Maximum DC Current Rating@45℃1 CoreAContinuous Current Rating@45℃3 CoreAShort Circuit Current 1sAOperating VoltageKV6/106/106/106/106/106/106/10Nominal Cross Section Areamm²Nominal Conductor Diametermm15.117.019.621.924.527.532.3Maximum DC Current Rating@45℃1 CoreAContinuous Current Rating@45℃3 CoreAShort Circuit Current 1sAOperating VoltageKV6/106/106/106/106/106/106/10Ambient Temperature Correction FactorsAmbient Temperature Correction FactorsRating Factor1.11.051.00.940.880.820.740.670.580.47Mechanical and Thermal PropertiesBending Radius 15×OD (during installation); 9×OD (fixed installed).Temperature Range -20℃ ~ +90℃.Dimensions and WeightConstruction No. of cores×Cross section(mm2)Nominal Insulation ThicknessmmNominal Sheath ThicknessmmNominal Overall DiametermmNominal Weightkg/kmInnerOuter1×163.41.51.124.09001×253.41.51.226.011401×353.41.61.226.912651×503.41.61.228.314601×703.41.71.330.017101×953.41.81.332.020601×1203.41.81.433.823801×1503.41.91.435.327001×1853.42.01.537.832251×2403.42.11.641.039901×3003.42.21.643.747601×4003.42.31.745.559001×5003.42.41.849.573501×6303.42.61.954.587503×163.42.31.746.033003×253.42.41.850.139053×353.42.51.852.243603×503.42.61.955.151853×703.42.72.058.961253×953.42.92.163.575003×1203.43.02.267.687753×1503.43.22.371.7102353×1853.43.42.474.0113003×2403.43.62.679.5133003×3003.43.82.785.016300
Other supplier products
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8105ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
Standards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed stranded copper,Website:, class 2 acco... |
|
|
|
Type 275 1.1/1.1KV to AS/NZS 1802ApplicationsThese cables are mainly used as a flexible feeder for shuttle cars and pump. Earth cores designed to r... |
|
|
|
600/1000V LSZH Insulated (single core) Application:The cables are mainly used in power stations,Website:, mass transit underground passenger system... |
|
|
|
XLPE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multitriple)RE-2X(St)H 90°C / 300 VSTANDARDSBasic design to EN 50... |