P3 Or P3/P10 RFOU/TFOU 6/10KV NEK606 Cable

P3 or P3/P10 RFOU/TFOU 6/10KV NEK606 MV CableApplicationsThese cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.StandardsIEC 60092-354; IEC 60092-351; IEC 60092-359; IEC 60332-1; IEC 60332-3-22; IEC 60754-1,2; IEC 61034-1,2; NEK 606:2004ConductorsCircular tinned annealed stranded copper to IEC 60228 class 2.Conductor ScreenSemi conducting material.InsulationHalogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation ScreenSemi conducting material and tinned copper wire braid.BeddingHalogen free compound.ArmourTinned copper wire braid.Outer SheathHalogen free thermosetting compound, SHF2 (for TYPE P3), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P3/P10),coloured red.Electrical CharacteristicsNominal Cross Section Areamm²Nominal Conductor Diametermm5.26.57.48.710.312.213.8Maximum DC Current Rating@45℃1 CoreAContinuous Current Rating@45℃3 CoreAShort Circuit Current 1sAOperating VoltageKV6/106/106/106/106/106/106/10Nominal Cross Section Areamm²Nominal Conductor Diametermm15.117.019.621.924.527.532.3Maximum DC Current Rating@45℃1 CoreAContinuous Current Rating@45℃3 CoreAShort Circuit Current 1sAOperating VoltageKV6/106/106/106/106/106/106/10Ambient Temperature Correction FactorsAmbient Temperature Correction FactorsRating Factor1.11.051.00.940.880.820.740.670.580.47Mechanical and Thermal PropertiesBending Radius 15×OD (during installation); 9×OD (fixed installed).Temperature Range -20℃ ~ +90℃.Dimensions and WeightConstruction No. of cores×Cross section(mm2)Nominal Insulation ThicknessmmNominal Sheath ThicknessmmNominal Overall DiametermmNominal Weightkg/kmInnerOuter1×163.41.51.124.09001×253.41.51.226.011401×353.41.61.226.912651×503.41.61.228.314601×703.41.71.330.017101×953.41.81.332.020601×1203.41.81.433.823801×1503.41.91.435.327001×1853.42.01.537.832251×2403.42.11.641.039901×3003.42.21.643.747601×4003.42.31.745.559001×5003.42.41.849.573501×6303.42.61.954.587503×163.42.31.746.033003×253.42.41.850.139053×353.42.51.852.243603×503.42.61.955.151853×703.42.72.058.961253×953.42.92.163.575003×1203.43.02.267.687753×1503.43.22.371.7102353×1853.43.42.474.0113003×2403.43.62.679.5133003×3003.43.82.785.016300
Other supplier products
|
|
|
VDE Standard Industrial Cables H03VV-F/H03VVH2-F pplication and DescriptionThese cable types are especially suited for use on small appliances with... |
|
|
|
UL Industrial Cables THW/THW-2Application and DescriptionThe THW conductor is suitable for most current wiring solutions for residential,Website:, ... |
|
|
|
Multipair Individually and Overall Screened Cables-Belden Equivalent 8178ApplicationsThese cables have individually screened pairs laid up in a foi... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9830ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, CWB Screened Instrumentation Cables (Single Pair)RE-2Y(C)H 90°C / 300VSTANDARDSBasic design to EN 50288-7APP... |
供应产品
Same products