600/1000V Mica+XLPE Insulated, LSZH Sheathed Power Cables (Single Core)

600/1000V Mica+XLPE Insulated,Website:, LSZH Sheathed fire resistant Power Cables (Single-Core)Unarmoured Single core (CU/MGT+XLPE/LSZH 600/1000V Class 2)Armoured Single core (CU/MGT+XLPE/LSZH/AWA/LSZH 600/1000V Class 2)Application:This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.STANDARDS:Basic design to IEC 60502-1 / BS 6724FIRE PERFORMANCECircuit IntegrityIEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)System circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1);NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING600/1000 VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Mica glass tape covered by extruded cross-linked XLPE compoundInner Sheath (optional):Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1Armouring (optional): Aluminum wire armourOuter Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation Colour: Natural (other colors upon request)Sheath Colour: Orange (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -30°C – +90°CTemperature range during installation (mobile state): -20°C – +50°CMinimum bending radius: 8 x Overall Diameter (unarmoured cable)10 x Overall Diameter (armoured cable)Electrical PROPERTIESDielectric test:3500 V r.m.s. x 5' (core/core)Insulation resistance1000 MΩ x km (at 20°C)Short circuit temperature250°CCONSTRUCTION PARAMETERSConductorNominal Cross Section AreaNo./ Nominal Diameter of StrandsDia. ofConductorNominal Insulation ThicknessUnarmoured CableArmoured CableApprox. Overall DiameterApprox.WeighApprox. Overall DiameterApprox.Weightmm2No./mmmmmmmmkg/kmmmkg/km1.57/0.531.590.76.554--2.57/0.672.010.76.867--47/0.852.550.77.586--67/1.043.120.78.1110--107/1.354.050.79.2155--167/1.705.10.710.2220--257/2.146.420.911.9325--3519/1.537.650.913.2425--5019/1.788.9114.660018.57807019/2.1410.71.116.682020.510109519/2.5212.61.118./2.0314.211.220.5135024.5161015037/2.2515.751.422..2.5217.641.625.5204029.5244024061/2.2520.251.728.5265034.5306030061/2.5222.681.831.5326036.9369040065/2.8525.65235.4413041.5478050061/3.2028.82.239520045./2.5232.762.443.5660050./2.8537.052.648.5830056./3.2041.62.853.51000061.511980Electrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CUnarmouredCurrent-Carrying Capacities (Amp)ConductorcrosssectionareaReference Method 4(enclosed in conduitin thermally insulatingwall etc)ReferenceMethod 3(enclosed inconduit on a wall or in trunkingetc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal orvertical)Reference Method12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables,single-phasea.c. or d.c.3 or 4cables,3-phasea.c.2cables,single-phase a.c. ord.c3 or 4cables,3-phasea.c.2 cables,single-phasea.c. or d.c. flatand touching3 or 4cables,3-phasea.c. flatandtouchingor trefoil2 cables,single-phase a.c.or d.c. or flat and touching3 or 4cables,3-phasea.c. flatand touchingor trefoil2 cables,single-phasea.c. or d.c. or 3 cables threephase2 cables,single-phasea.c. or d.c. or3 cables threephase3 cables,trefoil3-phasephase a.c.mm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)NominalCrossSectionArea2 cablesd.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3and 4 (enclosedin conduit etc,in or on a wall)Ref. Methods 1and 11 (clippeddirect or on traystouching)Ref. Methods 3and 4 (enclosedin conduit etc,in or on a wall)Ref. Methods 1,Ref. Methods 1 and1111 and 12(in trefoil)(Flat and touching)1...87.96.86.86.86.8104.74.74.7444162.92.92.92.52.52.5  rxzrxzrxzrxzrxz251.851.850.311.91.850.191.851.60.271.651.60.1651.61.60.191.6351.351.350.291.351.350.181.351.150.251.151.150.1551.51.150.181.15500.9910.291.050.990.1810.870.250.90.860.1550.870.860.180.87700.680.70.280.750.680.1750.710.60.240.650.590.150.610.590.1750.62950.490.510.270.580.490.170.520.440.230.50.430.1450.450.430.170.461200.390.410.260.480.390.1650.430.350.230.420.340.140.370.340.1650.381500.320.330.260.430.320.1650.360.290.230.370.280.140.310.280.1650.321850.250.270.260.370.260.1650.30.230.230.320.220.140.260.220.1650.282400.190.210.260.330.20.160.250.1850.220.290.170.140.220.170.1650.243000.1550.1750.250.310.160.160.220.150.220.270.140.140.1950.1350.160.214000.120.140.250.290.130.1550.20.1250.220.250.110.1350.1750.110.160.1955000.0930.120.250.280.1050.1550.1850.10.220.240.090.1350.160.0880.160.186300.0720.10.250.270.0860.1550.1750.0880.210.230.0740.1350.150.0710.160.178000.056---0.0720.150.17---0.0620.130.1450.0590.1550.16510000.045---0.0630.150.165---0.0550.130.140.050.1550.165ArmouredCurrent-Carrying Capacities (Amp)Nominal Cross Section AreaReference Method 1 (clipped direct)Reference Method 11 (on perforated cable tray)Reference Method 12 (free air)In single-way ductsLaid direct in ground2 cables singlephase a.c. or d.c. flat and touching3 or 4 cables 3-phase a.c. flat and touching2 cables singlephase a.c. or d.c. flat and touching3 or 4 cables 3-phase a.c. flat and touching3 cables 3-phase a.c. trefoiltouching2 cables singlephasea.c. or d.c. ducts touching3 cables 3-phase a.c. trefoil touching2 cables singlephase a.c. or d.c. touching3 cables 3-phase a.c. trefoil touchingmm2AAAAAAAAAVoltage Drop (Per Amp Per Meter)NominalCrossSectionArea2 cablesd.c.2 cables singlephasea.c.3 or 4 cables three-phase a.c.2 cables singlephase a.c.3 or 4 cables, 3-phase a.c. touchingReference Method1& 11 (touching)Reference Method1, 11 & 12 (in trefoil touching)Reference Method 1 & 11 (Flat touching)In ductsIn groundIn ductsIn ground123456789mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m  rxzrxzrxz    500.980.990.2110.860.180.870.840.250.881.10.990.930.86700.670.680.20.710.590.170.620.60.250.650.80.70.70.61950.490.510.1950.550.440.170.470.460.240.520.650.530.560.461200.390.410.190.450.350.1650.390.380.240.440.550.430.480.371500.310.330.1850.380.290.160.330.310.230.390.50.370.430.321850.250.270.1850.330.230.160.280.260.230.340.450.310.390.272400.1950.210.180.280.180.1550.240.210.220.30.40.260.350.233000.1550.170.1750.250.1450.150.210.170.220.280.370.240.320.214000.1150.1450.170.220.1250.150.1950.160.210.270.350.210.30.195000.0930.1250.170.210.1050.1450.180.1450.20.250.330.20.280.186300.0730.1050.1650.1950.0920.1450.170.1350.1950.240.30.190.260.178000.0560.090.160.190.0860.140.1650.130.180.230.280.180.240.1610000.0450.0920.1550.180.080.1350.1550.1250.170.210.260.170.220.15Note: r = conductor resistance at operating temperaturex = reactancez = impedance


Отправить запрос, связаться с поставщиком

Кому: UNIVERSAL CABLES LIMITED
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

P30 RFOU-HCF / TFOU-HCF 6/10(12) kV Fire resistant NEK606 MV cableApplications :These cables are fire resistant,Website:, flame retardant, low smok...
Flame Retardant CAT5e Data Cables Application:Cat5E is a cable standard for Gigabit Ethernet and other network protocol,Website:, suitable for basi...
Type 409 1.1 to 22KV to AS/NZS 2802ApplicationsType 409 series cable is mainly used as a flexible feeder to machinery,Website:, more suitable as a ...
NSSHCGEOEU 0.6/1kV Coal Cutter Cable (High Tensile Stress) VDE 0250 Part 812ApplicationsThese cables are used for the connection of mobile machines...
0.6/1 kV HEPR Insulated,Website:, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Multicore)ApplicationThese cables are used for fixed...
Все товары поставщика

Похожие товары

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Продавец: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes