600/1000V Mica+XLPE Insulated, LSZH Sheathed Power Cables (Single Core)

600/1000V Mica+XLPE Insulated,Website:, LSZH Sheathed fire resistant Power Cables (Single-Core)Unarmoured Single core (CU/MGT+XLPE/LSZH 600/1000V Class 2)Armoured Single core (CU/MGT+XLPE/LSZH/AWA/LSZH 600/1000V Class 2)Application:This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.STANDARDS:Basic design to IEC 60502-1 / BS 6724FIRE PERFORMANCECircuit IntegrityIEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)System circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1);NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING600/1000 VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Mica glass tape covered by extruded cross-linked XLPE compoundInner Sheath (optional):Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1Armouring (optional): Aluminum wire armourOuter Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation Colour: Natural (other colors upon request)Sheath Colour: Orange (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -30°C – +90°CTemperature range during installation (mobile state): -20°C – +50°CMinimum bending radius: 8 x Overall Diameter (unarmoured cable)10 x Overall Diameter (armoured cable)Electrical PROPERTIESDielectric test:3500 V r.m.s. x 5' (core/core)Insulation resistance1000 MΩ x km (at 20°C)Short circuit temperature250°CCONSTRUCTION PARAMETERSConductorNominal Cross Section AreaNo./ Nominal Diameter of StrandsDia. ofConductorNominal Insulation ThicknessUnarmoured CableArmoured CableApprox. Overall DiameterApprox.WeighApprox. Overall DiameterApprox.Weightmm2No./mmmmmmmmkg/kmmmkg/km1.57/0.531.590.76.554--2.57/0.672.010.76.867--47/0.852.550.77.586--67/1.043.120.78.1110--107/1.354.050.79.2155--167/1.705.10.710.2220--257/2.146.420.911.9325--3519/1.537.650.913.2425--5019/1.788.9114.660018.57807019/2.1410.71.116.682020.510109519/2.5212.61.118./2.0314.211.220.5135024.5161015037/2.2515.751.422..2.5217.641.625.5204029.5244024061/2.2520.251.728.5265034.5306030061/2.5222.681.831.5326036.9369040065/2.8525.65235.4413041.5478050061/3.2028.82.239520045./2.5232.762.443.5660050./2.8537.052.648.5830056./3.2041.62.853.51000061.511980Electrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CUnarmouredCurrent-Carrying Capacities (Amp)ConductorcrosssectionareaReference Method 4(enclosed in conduitin thermally insulatingwall etc)ReferenceMethod 3(enclosed inconduit on a wall or in trunkingetc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal orvertical)Reference Method12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables,single-phasea.c. or d.c.3 or 4cables,3-phasea.c.2cables,single-phase a.c. ord.c3 or 4cables,3-phasea.c.2 cables,single-phasea.c. or d.c. flatand touching3 or 4cables,3-phasea.c. flatandtouchingor trefoil2 cables,single-phase a.c.or d.c. or flat and touching3 or 4cables,3-phasea.c. flatand touchingor trefoil2 cables,single-phasea.c. or d.c. or 3 cables threephase2 cables,single-phasea.c. or d.c. or3 cables threephase3 cables,trefoil3-phasephase a.c.mm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)NominalCrossSectionArea2 cablesd.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3and 4 (enclosedin conduit etc,in or on a wall)Ref. Methods 1and 11 (clippeddirect or on traystouching)Ref. Methods 3and 4 (enclosedin conduit etc,in or on a wall)Ref. Methods 1,Ref. Methods 1 and1111 and 12(in trefoil)(Flat and touching)1...87.96.86.86.86.8104.74.74.7444162.92.92.92.52.52.5 rxzrxzrxzrxzrxz251.851.850.311.91.850.191.851.60.271.651.60.1651.61.60.191.6351.351.350.291.351.350.181.351.150.251.151.150.1551.51.150.181.15500.9910.291.050.990.1810.870.250.90.860.1550.870.860.180.87700.680.70.280.750.680.1750.710.60.240.650.590.150.610.590.1750.62950.490.510.270.580.490.170.520.440.230.50.430.1450.450.430.170.461200.390.410.260.480.390.1650.430.350.230.420.340.140.370.340.1650.381500.320.330.260.430.320.1650.360.290.230.370.280.140.310.280.1650.321850.250.270.260.370.260.1650.30.230.230.320.220.140.260.220.1650.282400.190.210.260.330.20.160.250.1850.220.290.170.140.220.170.1650.243000.1550.1750.250.310.160.160.220.150.220.270.140.140.1950.1350.160.214000.120.140.250.290.130.1550.20.1250.220.250.110.1350.1750.110.160.1955000.0930.120.250.280.1050.1550.1850.10.220.240.090.1350.160.0880.160.186300.0720.10.250.270.0860.1550.1750.0880.210.230.0740.1350.150.0710.160.178000.056---0.0720.150.17---0.0620.130.1450.0590.1550.16510000.045---0.0630.150.165---0.0550.130.140.050.1550.165ArmouredCurrent-Carrying Capacities (Amp)Nominal Cross Section AreaReference Method 1 (clipped direct)Reference Method 11 (on perforated cable tray)Reference Method 12 (free air)In single-way ductsLaid direct in ground2 cables singlephase a.c. or d.c. flat and touching3 or 4 cables 3-phase a.c. flat and touching2 cables singlephase a.c. or d.c. flat and touching3 or 4 cables 3-phase a.c. flat and touching3 cables 3-phase a.c. trefoiltouching2 cables singlephasea.c. or d.c. ducts touching3 cables 3-phase a.c. trefoil touching2 cables singlephase a.c. or d.c. touching3 cables 3-phase a.c. trefoil touchingmm2AAAAAAAAAVoltage Drop (Per Amp Per Meter)NominalCrossSectionArea2 cablesd.c.2 cables singlephasea.c.3 or 4 cables three-phase a.c.2 cables singlephase a.c.3 or 4 cables, 3-phase a.c. touchingReference Method1& 11 (touching)Reference Method1, 11 & 12 (in trefoil touching)Reference Method 1 & 11 (Flat touching)In ductsIn groundIn ductsIn ground123456789mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m rxzrxzrxz 500.980.990.2110.860.180.870.840.250.881.10.990.930.86700.670.680.20.710.590.170.620.60.250.650.80.70.70.61950.490.510.1950.550.440.170.470.460.240.520.650.530.560.461200.390.410.190.450.350.1650.390.380.240.440.550.430.480.371500.310.330.1850.380.290.160.330.310.230.390.50.370.430.321850.250.270.1850.330.230.160.280.260.230.340.450.310.390.272400.1950.210.180.280.180.1550.240.210.220.30.40.260.350.233000.1550.170.1750.250.1450.150.210.170.220.280.370.240.320.214000.1150.1450.170.220.1250.150.1950.160.210.270.350.210.30.195000.0930.1250.170.210.1050.1450.180.1450.20.250.330.20.280.186300.0730.1050.1650.1950.0920.1450.170.1350.1950.240.30.190.260.178000.0560.090.160.190.0860.140.1650.130.180.230.280.180.240.1610000.0450.0920.1550.180.080.1350.1550.1250.170.210.260.170.220.15Note: r = conductor resistance at operating temperaturex = reactancez = impedance
Other supplier products
|
|
NF M 87-202 EISF |
wNF M 87-202 EISFAPPLICATIONThese NF M 87-202 EISF instrumentation cables are used to transmit analogue or digital signals in easurement and proces... |
|
|
600 1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) |
600/1000V XLPE Insulated,Website:, PVC Sheathed, Armoured Power Cables (2-5 Cores)CU/XLPE/PVC 600/1000V Class 2CU/XLPE/PVC/SWA/PVC 600/1000V Class ... |
|
|
Belden8315 |
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8315ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
P18 RU 0.6/1kV NEK606 Cable |
P18 RU 0.6/1kV NEK606 CableApplications :These cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used for control, po... |
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Sheath, 5kV ICEA S-75-381 |
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 15kV ICEA S-75-381ApplicationsThese cables are designed for connections be... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |