11KV Vacuum Circuit Breaker
11KV Vacuum Circuit Breaker
ZW32 series 11kv breakerare used in distribution systems. 11kv auto reclosers are used to make and break normal and fault currents. 11kv outdoor vcbcircuit breakers are fully equipped with sensors and a controller to provide a means of protection and control. In case of a line fault, breakers can break and make currents several times, thus avoiding longer network interruptions due to temporary faults.
The manufacture, design, and testing of the vcb 11kvbreaker by our electric power equipment ltdChina is based on current standards IEC 62271-100. We can give you the most competitive11kv circuit breaker price.
Application of 11KV Vacuum Circuit Breaker
The 11 KV vacuum circuit breaker is equipped with one integrated current transformer per pole. The current transformer has a ratio of 600 A:5A.
VCB rating for 11kvis for protection purposes and optimized for operation with the controller.
Technical Parameters of 11KV Vacuum Circuit Breaker
Products Type |
ZW32-12 |
Maximum System Voltage |
12kV |
Rated Continuous Current |
630A |
Rated Frequency |
50/60Hz |
Short Time Withstand Current |
20kA/1sec |
Mainly Active Load Current |
630A |
Number of Load-break Operations |
30 |
Short-circuit Making Current (peak) |
50kA |
Number of Making Operations |
5 times |
Cable Charging Current |
25A |
Line Charging Current |
|
Closed Loop Circuit Current |
630A |
Transformer Magnetizing Current |
22A |
Wet Condition-10sec Ph- Ph-Eth, Across Interrupters |
45kV |
DryCondition-1min,Ph- Ph, Phase to Earth |
42kV |
Dry Condition - 1 min AcrossInterrupter |
48kV |
Phase to Phase, Phase to Earth |
75kV |
Across Interrupter |
85kV |
Internal Arc Test |
20kA / 0.1 sec |
Arc Extinction Medium |
vacuum |
Insulation Medium |
vacuum |
Creepage Distance (Silicon) |
780mm |
Dry arcing distance |
≥200mm |
IP Level |
67 |
Closing/Opening Time |
1sec |
Mechanical Operations (Guaranteed) |
10000times |
Operating Temperature (*Manual Type) |
-25~+70℃ |
We are the professional electric power equipment ltd, and we have types of outdoor vacuum circuit breakerfor sale, if you have needs, please contact us.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
33KV SF6 Gas Load Break Switch | Application of 33KV SF6 Gas Load Breaker Switch The 33kv load break switchis made of a proven rugged, corrosion-resistant material (304L stainless... | |
Control Box-Feeder Terminal Unit | The feeder terminal(FTU) is a new HV switch control device of control cabinet enclosuresequipped with both the imported DSP high-speed sampling chi... | |
15KV SF6 Gas Load Break Switch | 15KV SF6 Gas Load Break Switch 15 kv pole mounted disconnect switch is suitable for rated voltage 15kV, rated current 630A, 50/60Hz distribution n... | |
15KV SF6 Gas Load Break Switch | 15 kv pole mounted disconnect switch is suitable for rated voltage 15kV, rated current 630A, 50/60Hz distribution network breaking. The load curren... | |
SF6 Gas 11 KV Load Break Switch | The 11 kv load break switch is suitable for the distribution network with the highest voltage 11kV, the rated current 630A, and the rated frequency... |
Похожие товары
Temperature Controller | Продавец: Tinko Instrument (Suzhou) Co., Ltd. | Tinko temperature controller industrialcan improve process efficiency, product quality and minimi... | |
Sequence Valve Gate Controller | Продавец: Tinko Instrument (Suzhou) Co., Ltd. | Tinko hydraulic valve gate controllerenables control of valve gate flow sequence and timing for p... | |
TSC-02 Stand Alone Controller | Продавец: Tinko Instrument (Suzhou) Co., Ltd. | Tinko TSC-02 integrated dual zone temperature controlleris suitable for small mold. The portable ... | |
TSC-01 Stand Alone Controller | Продавец: Tinko Instrument (Suzhou) Co., Ltd. | Tinko TSC-01 integrated single zone hot runner temperature controller is suitable for small mold.... | |
Touch Screen Hot Runner Controller | Продавец: Tinko Instrument (Suzhou) Co., Ltd. | M20 series touch screen hot runner temperature controllers are newly developed with latest achiev... |