UV Fade Meter Si48 manufacturer

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

Paints & Coatings: Color retention and chalking resistance testing for exterior building paints, automotive finishes, anti-corrosion coatings, and industrial paints.

Plastics & Rubber: Brittleness and cracking assessment for outdoor plastic pipes, sealing gaskets, tires, and PP/PVC materials.

Textiles & Leather: UV resistance testing for sunshade fabrics, outdoor sportswear, synthetic leather, and synthetic fibers.

Ink & Printing: Lightfastness verification for advertising prints, packaging materials, and various color inks.

Adhesives: Bonding stability testing of structural construction adhesives, tapes, and sealants under prolonged UV exposure.

Standards

ISO 11431. ISO 2135;

ASTM D5031. ASTM G151. ASTM G153;

JIS A 1415. JIS A 1439. JIS K 5701-1. AATCC TM16. JIS L 0842. JIS K 6404-4. JIS D 0205. JIS D 0202. JIS E 4037. JIS Z 0237. JIS Z 1528. JIS B 7751;

SAE J2020;

Technical Parameters

ParameterDescription
Light source Composed of carbon arcs between upper and lower carbon rods, the arc voltage and arc current can be adjusted according to specific models. For example, some models have an arc voltage of 50V and an arc current of 60A.
Filter Use specific glass filters, such as the Korex 7058 glass filter, to reduce unwanted radiation.
Temperature range The temperature inside the test chamber can be adjusted as needed, usually within a certain temperature range, such as 0-80 °C.
NameUV Fade Meter
ModelSi48ASi48
Light Source UV Long-Life Carbon Arc Lamp UV Long-Life Carbon Arc Lamp
Light Source Qty. 1 1
Continuous Lightning Time 48 hours 48 hours
Irradiance Wavelength 300 to 700nm 500±100W/m2
(at 390 to 700nm)
500±100W/m2
(at 390 to 700nm)
Test Item Light
Light + Spray on front face (Rain) - -
Dark - -
Dark + Spray on back face (Dew) - -
Temperature /
Humidity Range
Light BPT 63±3℃ (at 28~30W/m2) 63±3℃ (at 28~30W/m2)
Humidity 35~50±5%rh 50%rh or under (not controlled)
Light + Spray on
front face (Rain)
Chamber Temperature (CAT) - -
Dark Chamber Temperature (CAT) - -
Humidity - -
Dark + Spray on
back face (Dew)
Chamber Temperature (CAT) - -
Specimen Capacity excl. black panel sensor
and light receptor
102 (65x55x1mm) 102 (65x55x1mm)
Specimen Holder Inclined type 18 18
Specimen Rack Diameter φ508mm (200 in) φ508mm (200 in)
Rotation Speed 3 rpm 3 rpm
Electrical Specifications 50/60Hz Single phase, 200V, 41A Single phase, 200V, 21A
Earth Leakage Breaker (ELB) ELB: 50A ELB: 40A
Water Consumptions For wet bulb pot Tap water Pure water approx. 7L/h approx. 0.5L/h
For humidifier Pure water
For specimen spray Pure water - -
For wall cooling and back spray Tap water - -
For chamber temp.
control / refrigerator
Cooling tower water - -
Outer Dimensions Width x Depth x Height (including pipings) approx. 95x103x205cm (37.4x40.6x80.7in) 95x88x175cm (37.4x34.6x68.9in)
Operating Weight approx. 300kgs (661lbs) 280kgs (617lbs)
Standard Accessories Radiometer for Irradiance Calibration Optional Optional
Irradiance Automatic Control System - -
Black Panel Temperature Automatic Control System Optional Optional
Others - -

Accessories

(1) UVA-340/UVB-313 Fluorescent Lamps

(2) Standard Aluminum Specimen Holder

(3) Blackboard Thermometer

(4) Irradiance Calibration Sensor

(5) Pure Water Filter

(6) Automated Monitoring Software

Test Procedures

Sample Loading: Secure specimens to the sample holder. Fill any empty spaces with spacers to maintain chamber pressure.

Lamp Verification: Install corresponding UVA or UVB lamps according to test standards and record lamp operating time.

Cycle Setup: Configure light intensity, temperature, and condensation/spray cycle duration in the controller.

Test Initiation: Verify water supply system, start equipment, and allow instrument to enter automatic cycle testing mode.

Process Monitoring: Periodically review irradiance readings and operational curves on the touchscreen to ensure data remains within tolerance limits.

Result Evaluation: Remove samples after testing concludes. Assess aging degree via visual comparison, color difference measurement, or physical strength testing.

Maintenance Information

Lamp Maintenance: Replace lamps sequentially every 1600-2000 operating hours to maintain stable irradiance energy.

Water System Cleaning: Use deionized or distilled water exclusively. Clean the water tank regularly to prevent scale buildup that impairs heating efficiency.

Sensor Calibration: Calibrate the irradiance sensor every six months to ensure internationally valid test data.

Environmental Requirements:

The test chamber should be placed in a well-ventilated laboratory, and the fan filter should be cleaned regularly.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Photovoltaic module wire tube bending testing machine
Photovoltaic module wire tube bending testing machine Standard IEC 61730-2:2004: Photovoltaic (PV) Module Safety Qualification – Requirements for Testing CE Certification(Conformité Euro...
Syringe slide performance tester
Syringe slide performance tester The Syringe Slide Performance Tester is a specialized instrument designed to measure the push and pull forces of syringe plungers, ensuring smooth ...
Minimum ignition point test machine,Automated dust cloud ignition tester,IEC 61241
Minimum ignition point test machine,Automated dust cloud ignition tester,IEC 61241 Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction This machineis a way of testing the sensitivity of the ignition that the dust...
SUGA U48 Carbon Arc Aging Tester
SUGA U48 Carbon Arc Aging Tester Main purpose: The Si80 domestic carbon arc aging chamber is a comprehensive climate testing device mainly used to simulate the changes in material...
Mechanical load testing machine for photovoltaic modules
Mechanical load testing machine for photovoltaic modules The Mechanical Load Testing Machine for Photovoltaic Modules is engineered to evaluate the mechanical durability of both crystalline and thin-film ...
Все товары поставщика

Похожие товары

Walk-in Environmental Constant Temperature and Humidity Test Chamber
Walk-in Environmental Constant Temperature and Humidity Test Chamber Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T2423.3 Environmental Testi...
High reliability walk-in heat aging chamber
High reliability walk-in heat aging chamber Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Walk-in High-Temperature Ag...
Fully programmable walk-in climate simulation system
Fully programmable walk-in climate simulation system Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications High and Low Temperature Hu...
PV Degradation Testing Chamber
PV Degradation Testing Chamber Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Light Decay Test Chambe...
PV module acid corrosion test equipment supplier
PV module acid corrosion test equipment supplier Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Photovoltaic Acid Mist ...