Photovoltaic module exposure test equipment

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

(1)GB/T 6495.3 Photovoltaic Devices – Part 3: Measurement Principles for Terrestrial Photovoltaic (PV) Solar Devices with Reference Spectral Irradiance Data

(2)GB/T 9535 Crystalline Silicon Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval

(3)IEC 61215 Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval

(4)IEC 60904-1 Photovoltaic Devices – Part 1: Measurement of Photovoltaic Current-Voltage Characteristics

(5)IEC 60904-2 Photovoltaic Devices – Part 2: Requirements for Reference Solar Devices

(6)IEC 60904-6 Photovoltaic Devices – Part 6: Requirements for Reference Solar Modules

Parameters

ItemTechnical Requirement
Solar simulator classification Class B or better
Spectral distribution Compliant with GB/T 6495.3 standard solar spectrum
STC irradiance 1000 W/m²
STC cell temperature 25 ℃
NOCT irradiance 800 W/m²
Temperature measurement accuracy ±1 ℃
Temperature measurement repeatability ±0.5 ℃
Test mode Natural sunlight or solar simulator
Test parameters Photovoltaic module I-V characteristics

Features

Solar simulator compliant with IEC 60904 series standards, ensuring high result comparability

Spectral distribution strictly aligned with GB/T 6495.3 requirements for accurate measurement

Supports both STC and NOCT testing, covering key photovoltaic performance conditions

Test samples and reference devices positioned in the same plane perpendicular to incident light, reducing systematic measurement errors

High-precision temperature monitoring meets stringent photovoltaic standard requirements

Simple and flexible system configuration suitable for both laboratory and outdoor testing environments

Accessories

(1)Class B solar simulator compliant with IEC 60904-6

(2)Reference photovoltaic device compliant with IEC 60904-2 or IEC 60904-6

(3)Test sample mounting frame ensuring coplanar alignment with reference device

(4)Temperature measurement system with ±1 ℃ accuracy

(5)Irradiance monitoring device for real-time light intensity measurement

(6)Consumable temperature sensors for periodic calibration or replacement

(7)Consumable light source lamps replaced according to service life

Test Procedures

Calibrate the solar simulator and reference photovoltaic device before testing

Install the test module and reference device on the mounting frame, ensuring both are perpendicular to the incident light and in the same plane

Attach the temperature sensor firmly to the specified position on the back of the module

Set irradiance and temperature parameters according to the selected test condition

Avoid shading, reflection, or external light interference during testing

Measure and record the current–voltage (I-V) characteristics under defined conditions


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Sliding Bearing Fatigue Testing chamber
Sliding Bearing Fatigue Testing chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM D2596 / ASTM D2783 / IP 239 EP, DIN 51350 / 1-5. ISO / CD 11008. VW 1444. V...
Safety Helmet Chin-strap Strength Tester
Safety Helmet Chin-strap Strength Tester The Safety Helmet Chin-strap Strength Tester is designed to evaluate the tensile strength and reliability of chin straps on industrial, sports, and...
Textile Thermal Insulation Property Tester
Textile Thermal Insulation Property Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB/T 41560-2022 (China): Specifies thermal resistance testing protocols for prote...
Medical Face Mask Differential Pressure Tester
Medical Face Mask Differential Pressure Tester The Medical Face Mask Differential Pressure Tester, also known as the Mask Breathability Tester, is designed to evaluate the breathability of medic...
Fuel Cell Air Intake Filter Test System,DIN 71460 Filter Test System
Fuel Cell Air Intake Filter Test System,DIN 71460 Filter Test System Whats/App: +86 156 1874 6768 Web: standard-groups.com The Fuel Cell Air Intake Filter Test System is designed to evaluate air intake filters for ...
Все товары поставщика

Похожие товары

Custom PV Hail Impact Tester
Custom PV Hail Impact Tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The machine is designed to mee...
Backsheet bonding strength tester for solar modules
Backsheet bonding strength tester for solar modules Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The tester is designed to comp...
Alternative to Wet leakage current test system of photovoltaic module
Alternative to Wet leakage current test system of photovoltaic module Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The Wet Leakage Current Test S...
Photovoltaic module exposure test equipment
Photovoltaic module exposure test equipment Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)GB/T 6495.3 Photovoltaic De...
Freeze thaw cycle test chamber
Freeze thaw cycle test chamber Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)GB/T 9535 Crystalline Silic...