Photovoltaic module exposure test equipment
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
(1)GB/T 6495.3 Photovoltaic Devices – Part 3: Measurement Principles for Terrestrial Photovoltaic (PV) Solar Devices with Reference Spectral Irradiance Data
(2)GB/T 9535 Crystalline Silicon Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval
(3)IEC 61215 Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval
(4)IEC 60904-1 Photovoltaic Devices – Part 1: Measurement of Photovoltaic Current-Voltage Characteristics
(5)IEC 60904-2 Photovoltaic Devices – Part 2: Requirements for Reference Solar Devices
(6)IEC 60904-6 Photovoltaic Devices – Part 6: Requirements for Reference Solar Modules
Parameters
| Item | Technical Requirement |
|---|---|
| Solar simulator classification | Class B or better |
| Spectral distribution | Compliant with GB/T 6495.3 standard solar spectrum |
| STC irradiance | 1000 W/m² |
| STC cell temperature | 25 ℃ |
| NOCT irradiance | 800 W/m² |
| Temperature measurement accuracy | ±1 ℃ |
| Temperature measurement repeatability | ±0.5 ℃ |
| Test mode | Natural sunlight or solar simulator |
| Test parameters | Photovoltaic module I-V characteristics |
Features
Solar simulator compliant with IEC 60904 series standards, ensuring high result comparability
Spectral distribution strictly aligned with GB/T 6495.3 requirements for accurate measurement
Supports both STC and NOCT testing, covering key photovoltaic performance conditions
Test samples and reference devices positioned in the same plane perpendicular to incident light, reducing systematic measurement errors
High-precision temperature monitoring meets stringent photovoltaic standard requirements
Simple and flexible system configuration suitable for both laboratory and outdoor testing environments
Accessories
(1)Class B solar simulator compliant with IEC 60904-6
(2)Reference photovoltaic device compliant with IEC 60904-2 or IEC 60904-6
(3)Test sample mounting frame ensuring coplanar alignment with reference device
(4)Temperature measurement system with ±1 ℃ accuracy
(5)Irradiance monitoring device for real-time light intensity measurement
(6)Consumable temperature sensors for periodic calibration or replacement
(7)Consumable light source lamps replaced according to service life
Test Procedures
Calibrate the solar simulator and reference photovoltaic device before testing
Install the test module and reference device on the mounting frame, ensuring both are perpendicular to the incident light and in the same plane
Attach the temperature sensor firmly to the specified position on the back of the module
Set irradiance and temperature parameters according to the selected test condition
Avoid shading, reflection, or external light interference during testing
Measure and record the current–voltage (I-V) characteristics under defined conditions
在线联系供应商
Other supplier products
| FAA insulation burn through test burner | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This system is applicable to aviation fuel fire testing of a wide range of aer... | |
| Intramedullary Nails Four - point Bending Fatigue Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0591-2011: Chinese standard specifying bending fatigue test methods for intr... | |
| Accelerated Weather Tester(Xenon)丨 Accelerated Weather Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits 1.Equipped with high-pressure xenon lamps, accurately reproduce th... | |
| Helmet Wearing Height Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The helmet wearing height testing machine is a testing device used to evaluate the comfort ... | |
| Motor Air Tightness Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Motor Air Tightness Tester is designed to evaluate the sealing performance of electric ... |
Same products
| Two-Shot Injection Molds | 卖方: WIT MOLD LIMITED | Two-Shot Injection Molds Advantages of two-shot injection molding The benefits of Double Inject... | |
| precision injection molding | 卖方: WIT MOLD LIMITED | precision injection molding Precision injection moldingis a method demanding unparalleled accura... | |
| Custom Plastic Molds molding | 卖方: WIT MOLD LIMITED | Custom Plastic Molds molding Plastic Molds molding servicesprovide many extremely versatile part... | |
| Thermoset Molding | 卖方: WIT MOLD LIMITED | Thermoset Molding Key Aspects of Thermoset Molding Materials: Thermosetting Polymers:These inc... | |
| PE Film Scrap, Rolls, Bale, Regrinds, Lump, LLDPE, HDPE, LDPE | 卖方: Plastic scrap, ferrous and non-ferrous metal scraps supplier for recycling | 我们供应各种PE薄膜废料,包括LLDPE、HDPE和LDPE,可持续发往全球各地的买家。我们的库存包含优质的捆包、卷材、块状和再生料,均经过精心分拣和处理,以满足塑料回收商和制造商的需求。我们保... |