cyclone dust collector
Introduction:
The CLP-B type cyclone dust collector can be used either alone or in combination with multiple cylinders. It is connected by a common gas inlet
and outlet gas cylinder to satisfy any smoke volume treatment. The unit of each dust collector has four parts: body, volute, core tube and sealed
dust collection device with good performance.
The working principle of the CLP-B cyclone dust collector after adding the bypass is that the dust-laden gas enters the tangential direction from
the entrance. When the air flow obtains the rotating motion, the air flow is separated from the upper and the lower to form a double-scroll
cochlear motion. The dust is in the double-scroll There is a strong separation effect at the boundary. The coarser dust particles are separated to
the outer wall with the down spiral vortex flow. Part of the dust is led out from the central hole of the bypass separation chamber, and the
remaining dust is carried by the downdraft. The upper vortex air flow has aggregating effect on fine-grained dust, thereby improving the dust
removal efficiency. This part of the finer dust particles, from the upper spiral vortex to the upper part, forms a strongly rotating upper dust ring
under the top cover, and enters the upper hole of the bypass separation chamber together with the upper spiral worm gas flow, and is introduced
into the cone through the return air inlet. With the internal air flow, the purified gas is discharged from the exhaust pipe, and the separated dust
enters the hopper.
Structure size:
1. The size of the exhaust pipe The depth of the exhaust pipe should be at the interface between the upper and lower air swirlers. Exhaust pipe
insertion depth and dust removal efficiency. The depth of insertion is about 1/3 of the height of the intake day; and it has nothing to do with the
type of dust, the particle size distribution, and the inlet gas velocity. The deeper the insertion depth of the exhaust pipe, the greater the pressure
loss.
2. Bypass Separation Chamber Side Separation Separation The top side seam of the bypass chamber introduces the upper vortex gas flow into
the bypass separation chamber. The cone side seam introduces the dust ring formed by the lower spiral in the upper cone into the bypass
separation chamber. The height of the side seam is generally the distance from the top edge of the inlet to the top cover.
If you need, please feel free to contact Miss. Livia
Отправить запрос, связаться с поставщиком
Другие товары поставщика
long bag low pressure pulse dust collector | Introduction: Long bag off-line pulse dust remover is mainly composed of upper tank, middle tank, ash hopper, air inlet flow pipe, bracket, filter... | |
2015 lower cost higher profitable no pollution waste plastic recycling machine | Working principle:First, the raw materials are put into the reactor, and then seal the feeding in door, later start the machine and the reactor wil... | |
Cartridge type industrial dust collector | Features: 1, high dust removal efficiency. Can filter fine dust, general filter cartridge filter accuracy of 5 ~ 7 microns, filtration efficiency ... | |
High efficiency 25micron fiberglass EPE filter 1.060LAH20SL-000-6-PX | High efficiency 25micron fiberglass EPE filter 1.060LAH20SL-000-6-PX Introduction: EPE filter element is widely used in the hydraulic system and lu... | |
CS604LGH13 Pall коалесцентный фильтр-картридж | Brand Name:Pall Model Number:CS604LGH13 Nominal filtration rating:0.1um~100um Application: Operating pressure:10-210bar Filter:Filter Working... |