ASTM E84 Building Materials Flame Spread Test Apparatus,Steiner Tunnel Test Furnace
The ASTM E84 Building Materials Flame Spread Test Apparatus is designed to evaluate the combustion performance of flooring, ceiling, wall coverings, as well as insulation and thermal materials. You can accurately measure the Flame Spread Index (FSI) and Smoke Developed Index (SDI), allowing you to assess the fire safety of materials in real-world applications. This instrument provides reliable data to support building material safety design and compliance.
Application
Interior and exterior building materials: Testing flame spread performance of floors, walls, and ceilings.
Insulation and thermal materials: Fire performance evaluation of polyurethane, mineral wool, glass wool, and other insulation products.
Furniture and composite panels: Fire resistance testing for plywood, upholstered furniture, and other wood or composite materials.
Other interior materials: Fire testing of coatings, wallpapers, and decorative panels.
Compatible test products: Tunnel furnace, dual-head flame nozzle, smoke collection system.
Standards
This test apparatus conforms to the following international standards:
ASTM E84 — Standard Test Method for Surface Burning Characteristics of Building Materials
NFPA 255 — Standard Method of Test of Surface Burning Characteristics of Building Materials
UL 723 — Standard for Test for Surface Burning Characteristics of Building Materials
ISO 5660 — Fire Testing — Heat Release and Flame Spread Measurements
Parameters
| Parameter | Specification |
|---|---|
| Test Method | ASTM E84 / NFPA 255 / UL 723 |
| Flame Source | Dual-head nozzle of tunnel furnace |
| Test Duration | 10 minutes |
| Measured Indicators | Flame Spread Index (FSI), Smoke Developed Index (SDI) |
| FSI Classification | Class A: 0–25Class B: 26–75Class C: 76–200 |
| SDI Range | 0–450 |
| Applicable Materials | Wood, composite panels, decorative materials, insulation/thermal materials |
Features
Accurate Measurement: Quantifies fire performance through FSI and SDI values.
Multi-Standard Compliance: Supports ASTM, UL, NFPA, and other international standards.
Safe and Reliable: Controlled testing process ensures stable and repeatable data.
Easy Operation: Simple sample installation and test procedure suitable for routine lab use.
Wide Applicability: Covers interior and exterior decoration, insulation materials, and furniture panels.
Accessories
Tunnel furnace main unit
Dual-head flame nozzle
Sample mounting fixtures
Smoke collection and analysis system
Data acquisition and recording system
Test Procedures
Mount the test sample on the sample rack at the top of the tunnel furnace.
Start the tunnel furnace; flames are emitted from the dual-head nozzle onto the sample.
Conduct the test for 10 minutes, recording flame spread and smoke development.
Calculate the Flame Spread Index (FSI) based on flame propagation distance and time.
Measure the Smoke Developed Index (SDI) and classify the material according to ASTM E84 standards.
Maintenance Information
Regularly clean the flame nozzles and furnace to remove carbon deposits for uniform flame distribution.
Calibrate smoke collection devices and sensors quarterly to ensure accurate measurements.
Keep sample fixtures and supports intact to prevent deformation affecting results.
Turn off power and ventilate the lab after use to prevent smoke residue from damaging equipment.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Timken Test Machine | The extreme pressure friction testing machine mainly consists of a main frame, a spindle transmission system, a test force loading mechanism, a lub... | |
| Spinal Internal Fixation Components System Tester | Standard YY/T 0961-2014 (China): Specifies static/fatigue testing protocols for spinal fixation systems, including connection integrity and anti-l... | |
| Catheter Residual Vacuum Tester | The Catheter Residual Vacuum Tester is a professional device used to detect the residual vacuum in respiratory suction catheters, aiming to ensure ... | |
| Syringe Sealing Negative Pressure Test device | Meet the standard YY0053-2008. GB 15810-2019 single-use sterile syringe, ISO7886-1:2017 single-use sterile syringe, ISO7886-1. ISO8537-2016. YY04... | |
| Spinneret Inspection Microscope,automatic spinneret mirror inspection instrument | Introduction ① Mechanical Components Overview 1. This machine employs an X-Y-Z three-axis motion control platform with AC servo systems for posit... |
Похожие товары
| Damp Freeze and Thermal Cycling Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Damp Freeze and Thermal ... | |
| Alternative to BBA steady state solar simulator tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The BBA Steady-State Solar S... | |
| Alternative to PV Hail Impact Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Hail Impact Test Machine... | |
| Solar Panel Insulation Resistance Test Chamber | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is applicable in ... | |
| 90-Degree Peel Tester for PV Backsheets | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is suitable for e... |