BSS 7365Flame Spread Tester for Thermal and Acoustic Insulation Materials

The Flame Spread Tester for Thermal and Acoustic Insulation Materials is designed to evaluate the flame propagation characteristics of insulation and acoustic materials. You can expose samples to a standard thermal radiation source and ignite them with a controlled flame to determine their critical heat flux. This instrument is FAA-approved and compliant with international standards, providing accurate and repeatable measurements for aerospace, civil aviation, and material development applications.

Application

You can apply this tester in the following scenarios:

Aerospace material testing: Evaluate flame propagation of thermal and acoustic insulation materials in aircraft interiors.

Civil aviation compliance: Test materials in accordance with FAA FAR Part 25 Appendix F Part VI.

Material development: Assess thermal and acoustic insulation performance during R&D.

Quality control: Monitor flame spread properties in production lines to ensure safety compliance.

Compatible test standards and protocols: FAR Part 25 Appendix F Part VI, Airbus AITM 2.0053. Boeing BSS 7365. MH/T 6042‑2006. and relevant national standards.

Standards

This tester conforms to the following national and international standards:

GB/T 27904‑2011 — Test method for flame spread of interior decoration materials

GB/T 25207‑2010 — Classification of combustion performance of building decorative materials

GB 8624‑2012 — Classification of burning behavior of building materials and products

GB/T 16172‑2007 — Determination of heat release rate and total heat release of building materials and products (Cone Calorimeter Method)

BSS 7365 — UK aerospace standard for combustion and smoke density of aerospace composite and interior materials

AITM 2.0053 — European aerospace industry method for heat release rate and smoke evaluation

FAR Part 25 Appendix F Part VI — FAA regulatory requirement for flame propagation, smoke density, and toxicity in civil aircraft cabin materials

Parameters

ParameterSpecification
Dimensions 1220 × 570 × 520 mm; 1200 × 1150 × 1350 mm; 800 × 800 × 400 mm
Weight 185 kg
Thermal Radiation Source 400 VAC, 3-phase electric heating plate, PID control, ±0.1°C accuracy
Radiation Strip Width 76 mm, six strips, operational up to 704°C
Sample Angle 30° relative to horizontal plane
Ignition System Axially symmetric propane burner, 0.15 mm nozzle
Burner Height Flame at least 51 mm above sample plane
Flame Spread Measurement Laser pointer for accurate monitoring
Thermocouple Placement Back wall 279 mm, right wall 292 mm, below radiation plate 51 mm, ±2°C accuracy
Heat Flux Range ≥60 kW/m², with self-circulating cooling water
Heat Flux Mounting Steel plate 3.2 mm thick, with 3 × 25.4 mm insertion holes
Sample Holders Standard and short versions (for hook-and-loop tests)
Data Acquisition Computer and printer, automatic test timing ±0.1 s

Features

Enclosed test chamber: Includes integrated chimney and controlled radiation environment.

Precision thermal radiation source: PID-controlled electric heating plate ensures uniform, stable heat flux.

Automated sample handling: Pneumatic sliding drawer allows easy sample insertion and removal.

Accurate ignition and flame monitoring: Propane burner with laser pointer ensures precise flame spread measurement.

Thermocouple monitoring: Accurately records sample and chamber temperatures at multiple points.

High-performance heat flux system: Measures critical heat flux for ignition and flame propagation.

Data acquisition and automation: Test time, flame spread, and other parameters are recorded automatically and with high precision.

Safety and repeatability: Controlled combustion and automated monitoring ensure consistent and safe testing conditions.

Accessories

Enclosed radiation test chamber with integrated chimney

3-phase electric heating plate with PID temperature control

Pneumatic sliding drawer for sample insertion and removal

Propane burner with 0.15 mm nozzle

Laser pointer for flame spread measurement

Thermocouples and mounting accessories

Water-cooled heat flux measurement system

Standard and short sample holders

Computer and printer with data acquisition system

Test Procedures

Install the sample in the test chamber using the pneumatic drawer and proper sample holder.

Connect the propane supply and compressed air system.

Activate the radiation source to achieve the desired thermal flux and preheat the sample.

Ignite the sample using the propane burner positioned 51 mm above the sample plane.

Monitor flame spread using the laser pointer and record temperature, heat flux, and ignition parameters via the data acquisition system.

Test duration is automatically recorded and ends at the set time or upon completion of flame propagation.

After testing, remove the sample and inspect the chamber for maintenance and cleaning.

Maintenance Information

Regularly clean the test chamber, radiation plate, and propane burner to ensure uniform heating and accurate measurements.

Calibrate thermocouples, heat flux system, and data acquisition equipment periodically.

Verify the pneumatic drawer and sample holders are operating smoothly.

Check propane and compressed air supplies before each test.

Maintain ambient temperature between 10–35°C for consistent testing conditions.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Sliding bearing PV friction testing machine
Sliding bearing PV friction testing machine Standard This machine is mainly applicable to GB 7948-1987 plastic bearing limit PV test method, JB/T 7381-2010 powder metallurgy oil bearing PV v...
Solid electrolyte analysis system
Solid electrolyte analysis system The Solid Electrolyte Analysis System is a precision testing platform designed to evaluate the ionic conductivity, electrochemical impedance, and i...
Fully Automatic Continuous Flow Reaction Calorimeter
Fully Automatic Continuous Flow Reaction Calorimeter Standards SN/T 3078.1. NY/T 3784. GB 51283 Product Features: 1. Using the coefficient calibration method and flow - regulation calorimetry, it c...
Limited Oxyen Index Tester,Automatic oxygen index test machine
Limited Oxyen Index Tester,Automatic oxygen index test machine Introduction STD Limited Oxyen Index Tester for the determination under the test conditions specified in oxygen and nitrogen gas mixture just to m...
Catheter Guidewire Friction meter
Catheter Guidewire Friction meter Test standard YY/T1536-2017.ISO 11070 Test principle The sample is clamped between the two chuck of the fixture, the two chuck do relative movem...
Все товары поставщика

Похожие товары

Damp Freeze and Thermal Cycling Tester
Damp Freeze and Thermal Cycling Tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Damp Freeze and Thermal ...
Alternative to BBA steady state solar simulator tester
Alternative to BBA steady state solar simulator tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The BBA Steady-State Solar S...
Alternative to PV Hail Impact Tester
Alternative to PV Hail Impact Tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Hail Impact Test Machine...
Solar Panel Insulation Resistance Test Chamber
Solar Panel Insulation Resistance Test Chamber Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is applicable in ...
90-Degree Peel Tester for PV Backsheets
90-Degree Peel Tester for PV Backsheets Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is suitable for e...