OSU Rate of Heat Release Apparatus,Fire safety heat release tester for building materials

The OSU Rate of Heat Release Apparatus is a precision instrument designed to measure the heat release rate (HRR) of materials, primarily for aerospace applications. Originally developed by Smith at Ohio State University in 1972. this apparatus has become an FAA-approved testing instrument for evaluating the combustion behavior of aircraft materials. You can use it to accurately determine heat release rates, flame spread, and smoke generation in compliance with international aviation safety standards, including FAR Part 25 Appendix F Part IV, Airbus AITM 2.0006. and Boeing BSS 7322. Its stainless-steel combustion chamber, PID-controlled heating system, and advanced data acquisition software enable reliable, reproducible results in a controlled laboratory environment.

Application

The OSU Rate of Heat Release Apparatus is widely used in the following areas:

Aerospace Material Testing: Assess heat release, flame spread, and smoke generation of aircraft cabin materials according to FAA, Airbus, and Boeing standards.

Aircraft Interior Compliance: Evaluate materials for FAR Part 25 Appendix F Part IV, ensuring cabin safety during fire scenarios.

Material Research & Development: Determine thermal degradation and combustion characteristics of plastics, composites, and coatings for aerospace applications.

Fire Safety Laboratory Testing: Integrate HRR data with flame spread and smoke density evaluations to support fire safety certification.

Typical test materials include aircraft cabin panels, interior plastics, textiles, laminates, and composite materials.

Standards

The apparatus supports compliance with the following standards:

BSS 7322 – Aerospace materials flame spread, smoke density, and toxicity evaluation.

AITM 2.0006 – Aerospace materials flame spread and smoke generation measurement.

FAR Part 25 Appendix F Part IV – Aircraft cabin material flame spread and smoke toxicity requirements.

GB/T 27904‑2011 – Flame spread performance of interior decoration materials (can be combined with HRR testing).

GB 8624‑2012 – Classification of combustion performance of building materials and products (can be combined with HRR results).

Parameters

Parameter CategoryDetails
Dimensions 760 mm (W) × 1850 mm (H) × 850 mm (D)
Weight 218 kg
Combustion Chamber Stainless steel with high-temperature glass viewing window
Heat Radiation Source 4 Glowbar heating rods, up to 35 kW/m² flux
Temperature Control 2 independent PID controllers
Power Supply 220 V, 35 A
Operating Temperature 10°C – 35°C
Combustion Gas Methane
Auxiliary Gas Constant temperature and flow air supply

Features

Stainless-steel combustion chamber with high-temperature observation window.

Four Glowbar heating rods providing up to 35 kW/m² radiant heat flux.

Dual PID temperature controllers for precise heat regulation.

Fully automatic pneumatic sample feeding and shielded door system.

Upper stationary burner and movable lower burner for flexible testing.

Rotor flow meters for controlling upper and lower burner gas flow.

Movable T-shaped calibration burner and flow controller for system calibration.

Mass flow controllers automatically applied to thermopile calibration.

Water-cooled heat flux sensors for accurate measurement of irradiated heat.

Airflow temperature control system for constant temperature and flow within the test chamber.

Orifice flow meters to monitor flow rate and pressure entering the test chamber.

Integrated data acquisition system and standard HRR testing software.

Accessories

Water-cooled heat flux sensors

Pneumatic sample feeder and shielded door

Upper and lower burners with flow control

T-shaped calibration burner

Rotor and mass flow controllers

PID temperature controllers

Data acquisition hardware and HRR software

Test Procedures

Ensure installation space allows safe operation and access.

Connect the apparatus to a 220 V, 35 A power supply.

Provide constant-temperature, constant-flow auxiliary gas.

Connect methane as the combustion gas supply.

Mount the test sample in the combustion chamber.

Adjust Glowbar heating rods and set PID controllers to desired heat flux.

Activate the automatic sample feeder and shielded door system.

Ignite the sample and upper/lower burners.

Monitor heat release rate, temperature, and gas flow using the software interface.

Record data for HRR, flame spread, and smoke generation.

After testing, shut off gas supply and allow the chamber to cool before sample removal.

Maintenance Information

Inspect and clean the combustion chamber and viewing window regularly.

Check burners, gas lines, and flow meters before each test for leaks or blockage.

Calibrate heat flux sensors and PID controllers periodically to ensure accuracy.

Verify data acquisition system and HRR software functionality.

Replace worn or damaged safety interlocks and pneumatic components as needed.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Activated carbon wear resistance tester ​
Activated carbon wear resistance tester ​ Applicable standards: GB/T 30202.3-2013: This is the wear resistance test standard in the test method of coal-based granular activated carbon for ...
Alcohol abrasion tester
Alcohol abrasion tester The Alcohol Abrasion Tester is designed for evaluating the wear and friction resistance of coatings, prints, and surfaces under controlled laborato...
Walk in High Temperature Environmental Test Chamber
Walk in High Temperature Environmental Test Chamber Applications The High-Temperature Aging Chamber is a critical testing apparatus designed to simulate high-temperature and harsh environmental cond...
Fully Automatic Scratch Hardness Tester
Fully Automatic Scratch Hardness Tester Application Primary applications: Evaluation of scratch resistance on insulated single-layer or composite coated panels Determination of coating...
Infusion Pump Flow Rate Tester
Infusion Pump Flow Rate Tester Applications The infusion set flow rate tester is an instrument specifically designed for measuring and monitoring the flow rate of infusion sets....
Все товары поставщика

Похожие товары

Damp Freeze and Thermal Cycling Tester
Damp Freeze and Thermal Cycling Tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Damp Freeze and Thermal ...
Alternative to BBA steady state solar simulator tester
Alternative to BBA steady state solar simulator tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The BBA Steady-State Solar S...
Alternative to PV Hail Impact Tester
Alternative to PV Hail Impact Tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Hail Impact Test Machine...
Solar Panel Insulation Resistance Test Chamber
Solar Panel Insulation Resistance Test Chamber Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is applicable in ...
90-Degree Peel Tester for PV Backsheets
90-Degree Peel Tester for PV Backsheets Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is suitable for e...