Manikin Breathing System
Application
HVAC education and research, including indoor air quality evaluation, human breathing exposure assessment in confined spaces, and cross-infection risk analysis of airborne diseases;
Medical and public health research, including studies on respiratory exposure, pollutant dispersion, and effectiveness of protective measures;
Occupational health assessment, such as evaluation of dust, PM2.5. and gaseous pollutant exposure in workshops and factories;
Breathing exposure assessment in aerospace cabins and confined environments, including civil and military aircraft, helicopters, space stations, re-entry capsules, submarines, and deep-sea systems;
Breathing exposure assessment inside vehicles and transportation systems, including buses, passenger cars, new energy vehicles, high-speed trains, subways, ships, and submarines;
Evaluation of breathing exposure and comfort of wearable masks, including space suits, pilot oxygen masks, aircraft passenger oxygen masks, and chemical protective mask systems.
Standards
GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)
GB/T 18883-2022 — Indoor Air Quality Standard
ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort
ASTM F1291-2020 — Test Methods Related to Breathing and Exposure Measurement
Product Specifications
| Component | Technical Parameters |
|---|---|
| Breathing Function | Sinusoidal breathing profile; breathing frequency 10 breaths/min (one cycle 6.0 s: exhalation 2.0 s, inhalation 2.0 s, pause 2.0 s); customizable on request |
| Exhalation Volume | Adjustable: 7 L/min, 15 L/min, 23 L/min; exhalation positive pressure 10–80 kPa (0.1–0.8 bar); inhalation negative pressure approx. −0.4 bar |
| Breathing Mode | Switchable nasal breathing or oral breathing (when used with a thermal manikin) |
| Exhaled Airflow | Equipped with heating module; airflow temperature adjustable from 34 to 36 °C |
| Sampling Branch | Main breathing line includes a sampling port for aerosol or pollutant sampling |
| Electrical Control System | Integrated control cabinet with pressure gauges and flow display; power supply AC 220 V / 50 Hz; total power ≤ 350 W; exhaled air heating module power ≤ 1000 W |
| Operating Environment | Temperature 10–40 °C; humidity 15–95% |
| Others | Can be used with a thermal manikin or independently with a manikin head; platform with lockable caster wheels; over-pressure and short-circuit protection; total weight approx. 45 kg |
Features
Accurate simulation of human breathing cycles and airflow parameters, with support for customized breathing functions;
Adjustable exhalation temperature to ensure experimental conditions are close to real human breathing;
Compatible with a 16-zone thermal manikin to simulate interaction between body heat sources and breathing airflow;
Modular design allowing independent use or localized experiments on specific body parts;
High-sensitivity airflow control components with millisecond-level response, using imported components from Germany;
Comprehensive safety protection, including over-pressure protection, short-circuit protection, and lockable caster wheels.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Toyota Specialized Abrasion Tester,ISO 5470,Abrasion Tester for Automotive Materials | The Toyota Specialized Abrasion Tester is designed to evaluate the abrasion resistance, color transfer, and surface durability of textiles, leather... | |
| Micro Rapid Closed Cup Flash Point Tester(Pensky Martens) | Automatic Flash Point Tester designed for accurate and repeatable determination of the flash point of petroleum products using the Pensky-Martens c... | |
| Paper Roughness and Air Permeability Tester ,Bendtsen Roughness & Air Permeability Tester | TheTMI Paper Roughness and Air Permeability Testeris a versatile laboratory instrument designed to simultaneously measure the surface roughness and... | |
| Glove Cut Resistance Tester | Product Introduction: The machine is used to test the cutting resistance of gloves. Under the specified load, the blade cuts the sample to measure... | |
| UL94 Horizontal Vertical Flame Tester,dual-axis flame tester | Introduction Rubber horizontal vertical flame testeris designed to simulate the early firing situation of electronic and electrical products in or... |
Похожие товары
| Textile Far - Infrared Radiation Heating Tester | Продавец: Standard International Group (HK) Limited | Applications Textile Far Infrared Radiation Temperature Rise Tester is used for various textiles... | |
| Fabric Far Infrared Energy Conversion Efficiency Analyzer | Продавец: Standard International Group (HK) Limited | Application Quality control and performance evaluation of natural fibers such as cotton and wool... | |
| Cloth Bound Water Release Rate Assessment System | Продавец: Standard International Group (HK) Limited | Application The tester is suitable for: (1) Apparel and sportswear R&D: assessing quick-dry... | |
| Automotive Textile UV Resistance Analyzer | Продавец: Standard International Group (HK) Limited | Applications Textile UV Protection Performance Tester is used to evaluate the ability of textile... | |
| Air-ventilation Aging Test Chamber | Продавец: Standard Groups | Designed for precise heat aging performance evaluation of electric wire, leather, plastic, rubber... |