.

Manikin Breathing System

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Application

HVAC education and research, including indoor air quality evaluation, human breathing exposure assessment in confined spaces, and cross-infection risk analysis of airborne diseases;

Medical and public health research, including studies on respiratory exposure, pollutant dispersion, and effectiveness of protective measures;

Occupational health assessment, such as evaluation of dust, PM2.5. and gaseous pollutant exposure in workshops and factories;

Breathing exposure assessment in aerospace cabins and confined environments, including civil and military aircraft, helicopters, space stations, re-entry capsules, submarines, and deep-sea systems;

Breathing exposure assessment inside vehicles and transportation systems, including buses, passenger cars, new energy vehicles, high-speed trains, subways, ships, and submarines;

Evaluation of breathing exposure and comfort of wearable masks, including space suits, pilot oxygen masks, aircraft passenger oxygen masks, and chemical protective mask systems.

Standards

GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)

GB/T 18883-2022 — Indoor Air Quality Standard

ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort

ASTM F1291-2020 — Test Methods Related to Breathing and Exposure Measurement

Product Specifications

ComponentTechnical Parameters
Breathing Function Sinusoidal breathing profile; breathing frequency 10 breaths/min (one cycle 6.0 s: exhalation 2.0 s, inhalation 2.0 s, pause 2.0 s); customizable on request
Exhalation Volume Adjustable: 7 L/min, 15 L/min, 23 L/min; exhalation positive pressure 10–80 kPa (0.1–0.8 bar); inhalation negative pressure approx. −0.4 bar
Breathing Mode Switchable nasal breathing or oral breathing (when used with a thermal manikin)
Exhaled Airflow Equipped with heating module; airflow temperature adjustable from 34 to 36 °C
Sampling Branch Main breathing line includes a sampling port for aerosol or pollutant sampling
Electrical Control System Integrated control cabinet with pressure gauges and flow display; power supply AC 220 V / 50 Hz; total power ≤ 350 W; exhaled air heating module power ≤ 1000 W
Operating Environment Temperature 10–40 °C; humidity 15–95%
Others Can be used with a thermal manikin or independently with a manikin head; platform with lockable caster wheels; over-pressure and short-circuit protection; total weight approx. 45 kg

Features

Accurate simulation of human breathing cycles and airflow parameters, with support for customized breathing functions;

Adjustable exhalation temperature to ensure experimental conditions are close to real human breathing;

Compatible with a 16-zone thermal manikin to simulate interaction between body heat sources and breathing airflow;

Modular design allowing independent use or localized experiments on specific body parts;

High-sensitivity airflow control components with millisecond-level response, using imported components from Germany;

Comprehensive safety protection, including over-pressure protection, short-circuit protection, and lockable caster wheels.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Medical Face Mask Synthetic Blood Penetration Tester
Medical Face Mask Synthetic Blood Penetration Tester Applicable Standards: GB 19083-2010 YY/T 0691-2008 YY 0469-2011 ISO 22609 ASTM F1862-07 Features: 1. Mask fixture is metal human head mold, ...
Carbon Black Content meter
Carbon Black Content meter Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB 13021-1991: Determination of carbon black content in polyethylene compounds. ...
Oil Separator Filtration and Separation Tester
Oil Separator Filtration and Separation Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Test System SPT for testing of separator, especially for blow-by oil mist sep...
Cloth Bowing Evaluation Device
Cloth Bowing Evaluation Device Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The instrument is widely used in: Textile R&D: Quantifying fabric hand fe...
Flame Propagation Test for a Single Insulated Cable IEC / EN 60332-1-2,EN 50086
Flame Propagation Test for a Single Insulated Cable IEC / EN 60332-1-2,EN 50086 Whats/App: +86 156 1874 6768 Web: standard-groups.com Description: This testermeetthe standards IEC 60332-1-1:2004 in the provisions of technic...
供应产品

Same products

Surface adhesion testing equipment factory price
Surface adhesion testing equipment factory price 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards JIS L 1066 (Testing Methods fo...
Continuous load scratch resistance tester manufacturer
Continuous load scratch resistance tester manufacturer 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO DIS 12137-2 (Plastics &mda...
High precision continuous load surface tester
High precision continuous load surface tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for...
Multi-function surface performance test system
Multi-function surface performance test system 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for...
Laboratory tribology research equipment
Laboratory tribology research equipment 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for...