Automotive Windshield Washer Nozzle Fatigue Testing Machine
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Windshield Washer Nozzle Fatigue Test Machine is designed to evaluate the durability and performance of automotive nozzles, including windshield cleaning nozzles (WCS) and headlamp cleaning nozzles (HCS). The machine operates within a controlled environmental chamber, allowing you to simulate temperature and fluid conditions while performing long-term fatigue tests on multiple components simultaneously. Its integrated control and data acquisition system ensures precise monitoring and reliable results.
Standards
The machine complies with international and national automotive testing standards, including:
ISO 6255:1997 – Passenger car windscreen washer systems – Test methods
SAE J942:1999 – Performance requirements and test procedures for passenger car windscreen washing systems
GB 15085‑2013 – Performance requirements and test methods for automotive windshield wipers and washer systems
GB/T 23436‑2009 – Automotive windshield cleaning fluid testing specification
Parameters
| Parameter | Details |
|---|---|
| Test Unit Dimensions | 2030 × 2550 × 1600 mm (W × H × D) |
| Internal Test Unit Dimensions | 1900 × 1150 × 1450 mm (W × H × D) |
| Rated Power | 4 kW |
| Working Fluid | Water – Ethanol mixture |
| Allowable Environment Temperature (Test Unit) | MIN: -25 °C / MAX: 80 °C |
| Number of Test Components | 20 (10 HCS / 10 WCS) |
Accessories
Nitrogen generator for chamber inerting
Fluid supply lines and fittings
Temperature and pressure sensors
Data acquisition modules
Explosion-proof ventilation system
Test Procedures
Install nozzles or components to be tested inside the test chamber.
Connect the working fluid supply (water-ethanol mixture).
Set desired environmental temperature and operational cycles.
Start the test using the PLC-based control unit.
Monitor real-time system parameters including chamber temperature, fluid flow, and nozzle operation.
The machine records all data automatically for later analysis.
After the test, safely remove the components and review recorded fatigue performance.
Maintenance Information
Regularly inspect fluid lines and nozzles to prevent blockage or residue accumulation.
Check nitrogen generator and explosion-proof suction system for proper operation.
Calibrate temperature and pressure sensors periodically for accurate measurements.
Clean the test chamber to remove flammable vapors and fluid residue.
Verify PLC control software and data acquisition integrity before each test cycle.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Helmet Xenon Aging Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The helmet xenon lamp aging tester is a device that simulates the damage caused by long-ter... | |
| ISO 11155 Cabin Air Filter Test System Manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Technical Data ParameterUnitValue ... | |
| ISO Certified Fan Efficiency Test System Factory | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards IEC 60879:2019 – Methods of Measuring the Performance of Ele... | |
| Hydraulic Oil Precision Filter Tester,ISO 4406 hydraulic fluid precision filtration device | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Hydraulic Oil Precision Filter Tester is a specialized filtration device for processing... | |
| Oxidation Induction Phase Analysis Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Differential Scanning Calorimeter DSC is designed to determine the inner heat transition re... |