Advanced haptic feedback skill logging system
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
You can apply the Haptic Skill Logger in the following scenarios and test objects:
(1) Evaluation of manual operation skills in product usage, including cosmetic application tools, switches, buttons, and handheld devices.
(2) Comparison of operation techniques between general users and trained professionals.
(3) Research on tactile behavior in virtual reality and human–machine interaction systems.
(4) Skill analysis for training and education, such as medical procedures, rehabilitation exercises, and technical skill learning.
(5) Consumer research for usability and tactile experience optimization of products applied directly to the skin.
(6) Academic research on haptic behavior, force control strategies, and motion characteristics.
Standards
At present, there is no dedicated international standard specifically for haptic skill logging systems. You may use this system in accordance with:
(1) Laboratory research methods related to tactile mechanics and human motion analysis.
(2) Experimental protocols used in usability evaluation, human factors engineering, and rehabilitation studies.
(3) Custom internal standards for product usability and skill assessment.
Parameters
| No. | Parameter | Specification |
|---|---|---|
| 1 | Wearable contact force sensor | 1 unit (size specified at time of purchase) |
| 2 | Wearable size options | Inner diameter: 11 mm, 12 mm, 14 mm, 16 mm, 18 mm |
| 3 | Built-in sensors | Strain-gauge contact force sensor, three-axis acceleration sensor |
| 4 | Calibration device | Rated capacity 30 N, resolution 16 bit |
| 5 | Connection method | USB ×2 |
| 6 | Software compatibility | Windows 7 (English version), 32-bit / 64-bit |
| 7 | Recommended CPU | Intel Core II Duo 2.5 GHz or higher |
| 8 | Display resolution | 1024 × 768 (XGA) |
| 9 | Operating temperature | 10 ℃ to 50 ℃, non-condensing |
| 10 | Weight | Approx. 2.5 kg (including packaging) |
| 11 | Optional functions | Trigger function, external synchronization function, wireless function, analysis software |
Accessories
(1) Haptic skill logging sensor unit.
(2) Calibration device.
(3) USB connection cables.
(4) Data logging and analysis software.
(5) User manual.
Test Procedures
(1) Install the sensing unit according to the intended operation task.
(2) Connect the system to the PC and launch the logging software.
(3) Perform individual calibration to ensure measurement accuracy.
(4) Start data logging and carry out the target operation naturally.
(5) Monitor force and motion signals in real time if required.
(6) Stop logging and save the recorded data for analysis and comparison.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Office Chair Caster Endurance Testing Machine (for Office Chair Caster Durability Tester) | Whats/App: +86 156 1874 6768 Web: standard-groups.com Implementation standards GB/T4085 EN425 Product features 1. The instrument adopts PLC to... | |
| Vibration Table | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM D999: Vibration testing of shipping containers and packaged products. TAP... | |
| Rail transit car wire abrasion testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Rail Transit Car Wire Abrasion Testing Machine is designed to evaluate the abrasion res... | |
| Shoe heel abrasion sample grinder manufacturer | Application This instrument is used for: (1)Footwear Testing Laboratories:Preparation of heel samples for abrasion testing. (2)Quality Control:E... | |
| Temperature Oxygen Index Apparatus, ISO4589-3, Nes 715 | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction: Temperature Oxygen IndexApparatus belongstoantiflamingtest equipment for mea... |
Похожие товары
| MMA-120 Handheld Arc Welder | Продавец: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |