Flue Gas Cleaning and Emission Control Equipment for Power Plants
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system conforms to the following international and national standards:
GB 16297-1996 – Comprehensive Emission Standard of Air Pollutants (China)
ISO 14001 – Environmental Management Systems
EN 1822 – High-Efficiency Air Filters (HEPA)
ASHRAE 52.2 – Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size
Parameters
| Unit | Specification |
|---|---|
| Pre-filter Unit | Fiber felt (folded structure), removes large particulates; frame: aluminum/galvanized; Filtration grade: G2. G3; High-temperature and corrosion resistant, low resistance |
| Medium Filter Unit | Folded bag-type fine filter; frame: aluminum; Filtration grade: G3; single metal mesh support; low initial resistance, large capacity |
| High-Efficiency Filter Unit | Ultra-fine glass fiber filter paper; filters 0.1–0.3 μm particles; frame: galvanized or ABS; Filtration grade: H10. H13. H14; high dust capacity, low resistance |
| Dimensions | 6400 mm (W) × 1700 mm (L) × 1800 mm (H) |
| Power Supply | AC 380V, 25 KW |
| Weight | Approximately 2.5 T |
Features
Steel structure cabinet with sealed design for durability and aesthetics.
Side-opening doors for easy replacement of consumables.
Heat exchange cooling system with exhaust duct, fan, heat exchanger, circulation pump, and piping for efficient gas cooling.
Exhaust duct equipped with heat exchanger; circulating water absorbs heat from high-temperature gas for effective cooling.
Electrostatic precipitation captures oil smoke particles via electron emission and charged particle attraction, effectively removing oil mist.
UV photolysis system efficiently eliminates VOCs, inorganic pollutants, H₂S, NH₃, thiols, and other odors.
Activated carbon adsorption concentrates harmful combustion by-products on its surface for further purification.
Exhaust fan controlled by a frequency inverter ensures adjustable smoke extraction.
Accessories
Pre-filter panels (G2/G3)
Medium filter bags (G3)
High-efficiency HEPA filters (H10/H13/H14)
Heat exchanger unit
UV photolysis lamp assembly
Activated carbon adsorption module
Exhaust fan and ductwork
Circulating water pump and piping
Test Procedures
Install and check all filter units, heat exchangers, and UV lamps.
Connect the system to the combustion equipment producing flue gas.
Start circulation pump and ensure water flow to the heat exchanger.
Power on the exhaust fan and set the desired extraction rate via frequency inverter.
Begin combustion experiment; monitor gas temperature, flow, and pollutant removal efficiency.
Periodically check filter units for dust load and replace if necessary.
Ensure UV lamps and activated carbon module operate effectively for VOC and odor removal.
Maintenance Information
Inspect filters monthly; replace pre-filters and medium filters every 3–6 months depending on use.
Clean high-efficiency filters carefully to maintain filtration efficiency.
UV lamps should be checked for intensity and replaced annually or as per manufacturer’s recommendations.
Heat exchanger and water circulation system should be inspected regularly for blockages or leaks.
Check and lubricate exhaust fan bearings periodically.
Ensure activated carbon modules are replaced when adsorption efficiency declines.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Laboratory Comprehensive Surface Performance Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 3960-2016 Plastics – Determination of Sliding Wear Properties ASTM G... | |
| Protective Clothing Resistance Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Related Standards GB/T 22042 - 2008 Clothing - Anti-static Performance - Test Method for S... | |
| Thermal Radiation Flooring Combustion Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Standards ISO 9239 - 1: Reaction to fire tests for floor coverings - Part 1: Deter... | |
| Falling Sand Abrasion Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The falling sand abrasion tester is used to test the abrasion resistance of coatings under ... | |
| High strength safety harness testing dummy manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The safety harness test dummy is used for dynamic load, overall static load, ... |
Похожие товары
| Высокоскоростная экструзионная линия для производства гофрированных труб с двойными стенками из ПЭВП с водяным охлаждением | Продавец: Shandong HUASU Plastic Technology Co.,Ltd. | Формы имеют структуру с двойным каналом потока и фильерную головку, обработанную азотированием и ... | |
| PanEVAP & MVR system | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... |