Flue Gas Cleaning and Emission Control Equipment for Power Plants

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The system conforms to the following international and national standards:

GB 16297-1996 – Comprehensive Emission Standard of Air Pollutants (China)

ISO 14001 – Environmental Management Systems

EN 1822 – High-Efficiency Air Filters (HEPA)

ASHRAE 52.2 – Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size

Parameters

UnitSpecification
Pre-filter Unit Fiber felt (folded structure), removes large particulates; frame: aluminum/galvanized; Filtration grade: G2. G3; High-temperature and corrosion resistant, low resistance
Medium Filter Unit Folded bag-type fine filter; frame: aluminum; Filtration grade: G3; single metal mesh support; low initial resistance, large capacity
High-Efficiency Filter Unit Ultra-fine glass fiber filter paper; filters 0.1–0.3 μm particles; frame: galvanized or ABS; Filtration grade: H10. H13. H14; high dust capacity, low resistance
Dimensions 6400 mm (W) × 1700 mm (L) × 1800 mm (H)
Power Supply AC 380V, 25 KW
Weight Approximately 2.5 T

Features

Steel structure cabinet with sealed design for durability and aesthetics.

Side-opening doors for easy replacement of consumables.

Heat exchange cooling system with exhaust duct, fan, heat exchanger, circulation pump, and piping for efficient gas cooling.

Exhaust duct equipped with heat exchanger; circulating water absorbs heat from high-temperature gas for effective cooling.

Electrostatic precipitation captures oil smoke particles via electron emission and charged particle attraction, effectively removing oil mist.

UV photolysis system efficiently eliminates VOCs, inorganic pollutants, H₂S, NH₃, thiols, and other odors.

Activated carbon adsorption concentrates harmful combustion by-products on its surface for further purification.

Exhaust fan controlled by a frequency inverter ensures adjustable smoke extraction.

Accessories

Pre-filter panels (G2/G3)

Medium filter bags (G3)

High-efficiency HEPA filters (H10/H13/H14)

Heat exchanger unit

UV photolysis lamp assembly

Activated carbon adsorption module

Exhaust fan and ductwork

Circulating water pump and piping

Test Procedures

Install and check all filter units, heat exchangers, and UV lamps.

Connect the system to the combustion equipment producing flue gas.

Start circulation pump and ensure water flow to the heat exchanger.

Power on the exhaust fan and set the desired extraction rate via frequency inverter.

Begin combustion experiment; monitor gas temperature, flow, and pollutant removal efficiency.

Periodically check filter units for dust load and replace if necessary.

Ensure UV lamps and activated carbon module operate effectively for VOC and odor removal.

Maintenance Information

Inspect filters monthly; replace pre-filters and medium filters every 3–6 months depending on use.

Clean high-efficiency filters carefully to maintain filtration efficiency.

UV lamps should be checked for intensity and replaced annually or as per manufacturer’s recommendations.

Heat exchanger and water circulation system should be inspected regularly for blockages or leaks.

Check and lubricate exhaust fan bearings periodically.

Ensure activated carbon modules are replaced when adsorption efficiency declines.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Ignition temperature tester
Ignition temperature tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Minimum Ignition Temperature Tester is a way of testing the sensitivity of the ignition...
UV Condensation Aging Test Chamber丨UV Condensation Aging Tester
UV Condensation Aging Test Chamber丨UV Condensation Aging Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM G154.ISO 4892-3.JIS K 7350. andSAE J2020for UV exposure testing. IEC 60068-...
Smoke Density Tester
Smoke Density Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Smoke Density Tester, developed by Rohm and Haas in the 1970s based on ASTM D2843. meas...
Vehicle Seat Active Headrest Impact Strength Test System
Vehicle Seat Active Headrest Impact Strength Test System Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Impact Strength Tester for Car Seat Launching Headrest is a specialized t...
Adjustable flame length tester
Adjustable flame length tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB/T 5169.5: Electrical & Electronic Equipment – Needle Flame Test Meth...
Все товары поставщика

Похожие товары

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Продавец: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...