Flue Gas Cleaning and Emission Control Equipment for Power Plants
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system conforms to the following international and national standards:
GB 16297-1996 – Comprehensive Emission Standard of Air Pollutants (China)
ISO 14001 – Environmental Management Systems
EN 1822 – High-Efficiency Air Filters (HEPA)
ASHRAE 52.2 – Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size
Parameters
| Unit | Specification |
|---|---|
| Pre-filter Unit | Fiber felt (folded structure), removes large particulates; frame: aluminum/galvanized; Filtration grade: G2. G3; High-temperature and corrosion resistant, low resistance |
| Medium Filter Unit | Folded bag-type fine filter; frame: aluminum; Filtration grade: G3; single metal mesh support; low initial resistance, large capacity |
| High-Efficiency Filter Unit | Ultra-fine glass fiber filter paper; filters 0.1–0.3 μm particles; frame: galvanized or ABS; Filtration grade: H10. H13. H14; high dust capacity, low resistance |
| Dimensions | 6400 mm (W) × 1700 mm (L) × 1800 mm (H) |
| Power Supply | AC 380V, 25 KW |
| Weight | Approximately 2.5 T |
Features
Steel structure cabinet with sealed design for durability and aesthetics.
Side-opening doors for easy replacement of consumables.
Heat exchange cooling system with exhaust duct, fan, heat exchanger, circulation pump, and piping for efficient gas cooling.
Exhaust duct equipped with heat exchanger; circulating water absorbs heat from high-temperature gas for effective cooling.
Electrostatic precipitation captures oil smoke particles via electron emission and charged particle attraction, effectively removing oil mist.
UV photolysis system efficiently eliminates VOCs, inorganic pollutants, H₂S, NH₃, thiols, and other odors.
Activated carbon adsorption concentrates harmful combustion by-products on its surface for further purification.
Exhaust fan controlled by a frequency inverter ensures adjustable smoke extraction.
Accessories
Pre-filter panels (G2/G3)
Medium filter bags (G3)
High-efficiency HEPA filters (H10/H13/H14)
Heat exchanger unit
UV photolysis lamp assembly
Activated carbon adsorption module
Exhaust fan and ductwork
Circulating water pump and piping
Test Procedures
Install and check all filter units, heat exchangers, and UV lamps.
Connect the system to the combustion equipment producing flue gas.
Start circulation pump and ensure water flow to the heat exchanger.
Power on the exhaust fan and set the desired extraction rate via frequency inverter.
Begin combustion experiment; monitor gas temperature, flow, and pollutant removal efficiency.
Periodically check filter units for dust load and replace if necessary.
Ensure UV lamps and activated carbon module operate effectively for VOC and odor removal.
Maintenance Information
Inspect filters monthly; replace pre-filters and medium filters every 3–6 months depending on use.
Clean high-efficiency filters carefully to maintain filtration efficiency.
UV lamps should be checked for intensity and replaced annually or as per manufacturer’s recommendations.
Heat exchanger and water circulation system should be inspected regularly for blockages or leaks.
Check and lubricate exhaust fan bearings periodically.
Ensure activated carbon modules are replaced when adsorption efficiency declines.
在线联系供应商
Other supplier products
| Solid Combustion Rate Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com This product complies with "Recommendations on the Transport of Dangerous Goods - Manual of... | |
| Cylindrical Battery In-Situ Volume Swelling Testing System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard UL 1642: Standard for Lithium Batteries IEC 62660-2: Secondary Lithium-Ion Cel... | |
| Integrated Material Surface Performance Testing Platform | Whats/App: +86 156 1874 6768 Web: standard-groups.com Integrated Material Surface Performance Testing Platform is a versatile system designed for... | |
| ASTM E662 smoke density tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument conforms to the following national and international standards: ... | |
| Catheter Hydraulic Leakage Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Hydraulic Leakage Tester is a testing instrument specifically developed and ma... |
Same products
| Gasket for Plate Heat Exchanger | 卖方: Hengshui Hongcan Import and Export Trading Co., Ltd | The sealing gasketin plate heat exchangers primarily serves to seal between hot and cold media. ... | |
| Energy Saver | 卖方: O&K GROUP LIMITED | Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies... | |
| ER1100 Aluminum Welding Wire | 卖方: 868776 | The ER1100 Aluminum Welding Wire from Hangzhou Kunli Welding Materials Co., Ltd. is designed for ... | |
| air conditioner | 卖方: O&K GROUP LIMITED | Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies... | |
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... |