Flue Gas Cleaning and Emission Control Equipment for Power Plants

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The system conforms to the following international and national standards:

GB 16297-1996 – Comprehensive Emission Standard of Air Pollutants (China)

ISO 14001 – Environmental Management Systems

EN 1822 – High-Efficiency Air Filters (HEPA)

ASHRAE 52.2 – Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size

Parameters

UnitSpecification
Pre-filter Unit Fiber felt (folded structure), removes large particulates; frame: aluminum/galvanized; Filtration grade: G2. G3; High-temperature and corrosion resistant, low resistance
Medium Filter Unit Folded bag-type fine filter; frame: aluminum; Filtration grade: G3; single metal mesh support; low initial resistance, large capacity
High-Efficiency Filter Unit Ultra-fine glass fiber filter paper; filters 0.1–0.3 μm particles; frame: galvanized or ABS; Filtration grade: H10. H13. H14; high dust capacity, low resistance
Dimensions 6400 mm (W) × 1700 mm (L) × 1800 mm (H)
Power Supply AC 380V, 25 KW
Weight Approximately 2.5 T

Features

Steel structure cabinet with sealed design for durability and aesthetics.

Side-opening doors for easy replacement of consumables.

Heat exchange cooling system with exhaust duct, fan, heat exchanger, circulation pump, and piping for efficient gas cooling.

Exhaust duct equipped with heat exchanger; circulating water absorbs heat from high-temperature gas for effective cooling.

Electrostatic precipitation captures oil smoke particles via electron emission and charged particle attraction, effectively removing oil mist.

UV photolysis system efficiently eliminates VOCs, inorganic pollutants, H₂S, NH₃, thiols, and other odors.

Activated carbon adsorption concentrates harmful combustion by-products on its surface for further purification.

Exhaust fan controlled by a frequency inverter ensures adjustable smoke extraction.

Accessories

Pre-filter panels (G2/G3)

Medium filter bags (G3)

High-efficiency HEPA filters (H10/H13/H14)

Heat exchanger unit

UV photolysis lamp assembly

Activated carbon adsorption module

Exhaust fan and ductwork

Circulating water pump and piping

Test Procedures

Install and check all filter units, heat exchangers, and UV lamps.

Connect the system to the combustion equipment producing flue gas.

Start circulation pump and ensure water flow to the heat exchanger.

Power on the exhaust fan and set the desired extraction rate via frequency inverter.

Begin combustion experiment; monitor gas temperature, flow, and pollutant removal efficiency.

Periodically check filter units for dust load and replace if necessary.

Ensure UV lamps and activated carbon module operate effectively for VOC and odor removal.

Maintenance Information

Inspect filters monthly; replace pre-filters and medium filters every 3–6 months depending on use.

Clean high-efficiency filters carefully to maintain filtration efficiency.

UV lamps should be checked for intensity and replaced annually or as per manufacturer’s recommendations.

Heat exchanger and water circulation system should be inspected regularly for blockages or leaks.

Check and lubricate exhaust fan bearings periodically.

Ensure activated carbon modules are replaced when adsorption efficiency declines.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Helmet Projection and Surface Friction tester
Helmet Projection and Surface Friction tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Purpose The Shear Force and Friction Tester for Helmet Surface Protrusions is mainly used ...
Heel impact fatigue testing machine丨Heel impact fatigue tester
Heel impact fatigue testing machine丨Heel impact fatigue tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Main uses: Heel impact fatigue testing machine is mainly used to test the continuous impac...
Sanitary Napkin Absorption Speed Test chamber
Sanitary Napkin Absorption Speed Test chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Main uses: The absorption speed tester is used to measure the absorption speed of sanitary...
Automatic Scratch Tester
Automatic Scratch Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automatic Scratch Tester is designed for evaluating the hardness and friction performan...
Xenon Lamp for Atlas Weatherometer
Xenon Lamp for Atlas Weatherometer Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction: Ci 3000-5000 4 thousand hours xenon lamp tester spare package, allows your d...
供应产品

Same products

Laser Cutting Machines
Laser Cutting Machines 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Laser Cutting Machines PrecisionLaser Cutting Systemsfor Film, Glass & Industrial Materials ...
Precision Laser Micromachining Machine
Precision Laser Micromachining Machine 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Precision Laser Micromachining Machine| Ultrafast Laser Micromachining Systems Chanxan provides ...
Ultrafast Laser Systems
Ultrafast Laser Systems 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Ultrafast Laser Systems Femtosecond Laser System Ultra-precision femtosecond laser systemfor hi...
Industrial Laser Equipment Manufacturer
Industrial Laser Equipment Manufacturer 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Industrial Laser Equipment Manufacturer for Precision Cutting, Marking & Micromachining Chan...
Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 卖方: 868983 Common Rail Injector Valve F00R J02 012 David Chen