ASTM C518 High-Precision Heat Flow Measurement System

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

ASTM C518: Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus.

ASTM C1784: Standard Test Method for Thermal Storage Performance of Phase Change Materials and Products Using a Heat Flow Meter Apparatus.

ISO 8301: Determination of Steady-State Thermal Resistance and Related Properties of Thermal Insulating Materials by Means of a Heat Flow Meter.

JIS A1412: Method for Determining Thermal Conductivity of Insulating Materials.

EN 12667: Thermal performance of building materials – Determination of thermal resistance by heat flow meter and guarded hot plate method for high and medium thermal resistance products.

EN 12664: Thermal performance of building materials – Determination of thermal resistance by heat flow meter and guarded hot plate method for medium and low thermal resistance dry and wet products.

Parameters

ModelMaterialSensor TypeThermal Conductivity (W/m·K)Specific HeatHigh Conductivity Kit (W/m·K)Sample Size (mm)Test Time (min)Accuracy (k)Repeatability (k)Plate Temp Range (°C)Factory CalibrationStandards
HFM-1 Insulation, solids, textiles Flux sensors (x2) 0.002–0.5 Optional Up to 2.5 300×300×max 100 30–40 1–2% 0.5–1% 20–75 Yes ASTM C518. C1784. ISO 8301. JIS A1412. EN 12667. EN 12664
HFM-2 Insulation, solids, textiles Flux sensors (x2) 0.002–0.5 Optional Up to 2.5 300×300×max 100 30–40 1–2% 0.5–1% -30–110 Yes ASTM C518. C1784. ISO 8301. JIS A1412. EN 12667. EN 12664
HFM-3 Insulation, solids, textiles Flux sensors (x2) 0.002–0.5 Optional Up to 2.5 200×200×max 50 30–40 1–2% 0.5–1% -20–70 Yes ASTM C518. C1784. ISO 8301. JIS A1412. EN 12667. EN 12664
HFM-4 Insulation, solids, textiles Flux sensors (x2) 0.01–0.3 N/A N/A Max 300×300×25 20 3% 1% 10–75 Yes ASTM C518. C1784. ISO 8301. JIS A1412. EN 12667

Features

Heat Flux Measurement: Thermopile-based sensors integrated with surface thermocouples; low calibration requirement improves measurement accuracy.

Temperature Control: Peltier elements provide precise heating and cooling, with temperature resolution <0.01°C for optimal thermal testing.

Thickness Measurement: Automated or manual sample thickness measurement using optical encoders with <0.05 mm accuracy, ensuring precise thermal resistance calculations.

Flexible Operation: Measurement via front control panel or HFM software on Windows; supports automated temperature steps, result export, and printing.

Clamping Control: Automatic for rigid materials; manual input for compressible materials ensures optimal contact.

Reference Materials: NIST-certified standard reference materials (SRM) included, with optional custom thermal standards for specialized applications.

Accessories

Standard reference materials (glass fiber board and EPS foam board).

Optional high thermal conductivity kit.

Sample support fixtures for small or irregular specimens.

Software package for Windows-based control and data management.

Test Procedures

Sample Preparation: Ensure parallel surfaces. Automated thickness measurement is available for rigid samples; manual input for compressible materials (~1 min).

Insert Sample: Place sample between test plates; center smaller or irregular samples (~1 min).

Close Plates: Upper plate automatically lowers; for compressible materials, stops at preset thickness. Plate briefly confirms contact to ensure measurement accuracy (~1 min).

Run Test: Choose single or progressive temperature steps; standard testing time 30–40 minutes. Results can be saved, printed, or exported to Excel.

Maintenance Information

Regularly clean sensor surfaces to prevent debris interference.

Calibrate periodically with NIST reference materials.

Inspect Peltier modules and optical encoders for mechanical wear or misalignment.

Store in a dry, dust-free environment when not in use.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

 Solids Spontaneously Igniting Tester
Solids Spontaneously Igniting Tester Conforms to the UN Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria 33.3.1.4 Test N.2: Test Methods for Pyrophori...
Haptic Skill Logger,advanced tactile detection sensor
Haptic Skill Logger,advanced tactile detection sensor Whats/App: +86 156 1874 6768 Web: standard-groups.com The Haptic Skill Logger is a measurement and recording system designed to quantitatively ca...
Automotive Wires Ozone Aging Chamber
Automotive Wires Ozone Aging Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 6722: Road vehicles – Electrical cables – Dimensions and test me...
Helmet Xenon Aging Tester
Helmet Xenon Aging Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T2014-9-19. ISO 4892 ASTM G151. G154. D4329 d4587、d4799、sae j2020 Xenon la...
Light transmittance fog meter
Light transmittance fog meter Applicable standards: GBT 2410-2008: Determination of light transmittance and fog degree of transparent plastics. This is the national standard of...
Все товары поставщика

Похожие товары

Benchtop Thermal Conductivity Tester for Insulation Materials
Benchtop Thermal Conductivity Tester for Insulation Materials Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument complies with a...
High-Accuracy Guarded Heat Flow Meter Thermal Conductivity Measurement System
High-Accuracy Guarded Heat Flow Meter Thermal Conductivity Measurement System Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument is designed and...
Heat Flow Method for Thermal Conductivity Measurement
Heat Flow Method for Thermal Conductivity Measurement Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument complies with a...
Benchtop Thermal Conductivity Tester
Benchtop Thermal Conductivity Tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument is designed and...
Guarded Heat Flow Measurement System
Guarded Heat Flow Measurement System Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM E1530: Standard Test Meth...