Roof Mounted Solar Panel Fire Test Equipment Manufacturer
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Roof-Mounted Photovoltaic Module Fire Test Apparatus is a specialized testing system developed in accordance with GB/T 30735-2014 for evaluating the external fire performance of roof-mounted photovoltaic modules and roofing products. Based on test principles derived from ENV 1187 (t1 method) and ISO 12468-1. the apparatus simulates different fire exposure conditions such as wind influence and thermal radiation. It provides standardized test methods for assessing the external reaction to fire of roof systems and roof coverings, supporting fire safety evaluation of photovoltaic installations on roofs.
Standards
The apparatus is designed to meet the requirements of the following standards:
(1) GB/T 30735-2014 – Test Method for Reaction to External Fire of Roofs and Roof Coverings
(2) ENV 1187: t1 – Test Methods for External Fire Exposure to Roofs
(3) ISO 12468-1:2013 (Method B) – Fire Performance of External Roofs and Roof Coverings — Part 1: Test Methods
(4) ISO 12468-1:2013 (Method C) – Fire Performance of External Roofs and Roof Coverings — Part 1: Test Methods
(5) UL 1703: multi-family and hotel room individual dwelling unit smoke detection monitors: electric signal detection of house dust;
(6)UL 790: standard method of fire test for roof covering materials;
(7)ASTM e 108-04: standard method of fire test for roof covering materials;
(8)NFPA 256: fire test of roof deck.
(9)IEC 61730-2 Appendix b: fire tests on PV modules.
Parameters
| Item | Specification |
|---|---|
| Radiant Panel Radiation Surface | 600 mm × 600 mm |
| Wood Crib Fire Gas Combustion Device | 1 set |
| Test Specimen Rack Angle | Adjustable, 0–50° |
| Air Duct Material | SUS304 stainless steel |
| Air Duct Thickness | 2 mm |
| Fan Airflow Capacity | Max. 250 m³/min |
| Fan Power | 5.5 kW |
| Fan Frequency Control | 3-phase 380 V, 5.5 kW |
| Air Duct Adjustable Angle | 0–35° |
| Impeller Anemometer | 3 units |
| Wind Speed Accuracy | 0.1 m/s |
Features
Frame-type structure for combustion and specimen holding systems, providing high mechanical stability.
Independent control cabinet and gas supply cabinet design, facilitating laboratory layout and improving operational safety.
Supplied with a compact stainless steel tube burner for wood shavings combustion tests.
Burner equipped with a silicon nitride igniter and UV flame detector, ensuring reliable ignition and real-time flame monitoring to prevent gas leakage.
Imported high-precision rotameter and branded pressure gauges for accurate control of fuel gas flow, combined with solenoid valves for automatic gas shutoff at the end of tests.
Specimen support frame constructed from welded metal square tubes and angle steel, ensuring rigidity during testing.
Adjustable specimen inclination angle using pneumatic actuation, allowing convenient push-button operation.
Fine honeycomb grille installed in the upper air duct and coarse honeycomb grille at the outlet to stabilize airflow.
Air duct angle adjustment driven by a ball screw and servo motor, enabling automatic and precise positioning.
Computer and dedicated software control the entire test process, ensuring convenient operation and reliable safety management.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Pendulum and charpy impact test machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications This advanced Pendulum Impact Tester is specifically tailored for evaluating ... | |
| Snap Button Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Snap Button Tester is a device specifically designed to test the durability of buttons ... | |
| High Precision Automotive Electrical Wire Thermal Stability Tester OEM Supplier | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Parameters ParameterSpecification Upper Clamps 3 Lower Clam... | |
| Compression Stocking Pressure Measurement Equipment | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The MST Clothing Pressure Tester/Underwear Pressure tester is used in the bod... | |
| Custom Medical injection needle puncture force tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument complies with domestic and international standards for medical ne... |