High Pressure Gas Pulsation Test Machine for Pipeline and Seal Testing Supplier China
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Features
Designed for testing automotive motor parts, particularly turbocharger pipelines.
Performs high-temperature pressure pulse testing under hot air conditions.
Equipped with a large environmental chamber for sample placement.
Pressure range from -0.5 to max. 5 bar.
Automatic leak detection and leak testing with fail-safe shutdown for defective samples.
Integrated robot for 3D motion simulation of test samples.
Windows-based control unit with real-time data recording.
Accessories
Environmental chamber with dual access doors
Linear and 3D robotic motion system
Pressure sensors and leak detection units
Air supply system with temperature and pressure control
Windows-based control and data acquisition software
Safety interlocks for failed samples
Sample mounting brackets for turbocharger components
Parameters
| Parameter Category | Details |
|---|---|
| Equipment Dimensions | 4100 × 2400 × 2000 mm (W × H × D) |
| Environmental Chamber Dimensions | 1500 × 1500 × 1000 mm (W × H × D) |
| Rated Power | 35 kW |
| Test Medium | Air |
| Pressure Range | -0.5 … 5 bar |
| Pressure Frequency | > 0 … 2 Hz |
| Pressure Waveform | Trapezoidal, near Sine |
| Air Medium Temperature Range | +30 … +250°C |
| Environmental Chamber Temperature | +30 … +250°C |
| Test Channels | 8 |
| Motion Device Frequency | > 0 … 2 Hz |
| Motion Device Amplitude | max. ±30 mm |
Test Procedures
Ensure the test area is safe and allows full access to all test channels.
Connect the system to a 35 kW power supply.
Supply pressurized air to the chamber and confirm temperature control settings (+30 to +250°C).
Mount the turbocharger, intercooler, or air-cooled system component in the environmental chamber.
Start the Windows control system and set pressure pulse range, waveform, frequency, and amplitude.
Activate the robotic 3D motion system to simulate operational stresses.
Monitor air pressure, temperature, and leak detection sensors during testing.
Automatically shut down any failed samples.
Record all test data for compliance and durability analysis.
After testing, allow the system to cool before removing samples.
Maintenance Information
Inspect motion devices, robotic arms, and pressure sensors before each test.
Verify air supply, tubing, and chamber seals for leaks.
Periodically calibrate pressure, temperature, and motion sensors.
Clean the environmental chamber and robotic components to prevent contamination.
Replace worn or damaged safety devices to maintain operational integrity.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| EN ISO 20344 water vapour permeability tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Leather Water Vapor Permeability Tester measures the ability of leather a... | |
| Minimum Ignition Temperature (MIT) – Dust Cloud Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Description Dust Cloud Minimum Ignition Temperature Tester is mainly used to assess the ex... | |
| In-situ expansion analysis system | Whats/App: +86 156 1874 6768 Web: standard-groups.com The In-situ Expansion Analysis System is designed for high-precision measurement of dimensi... | |
| Flexometer Bally Type Flex Testing Machine for Rubber | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Bally flex tester is designed to evaluate the flexural resistance of leather ... | |
| Optical glass scratch resistance testing machine manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Glass Scratch/Abrasion Tester is used to test the scratch and abrasion re... |
Похожие товары
| MMA-120 Handheld Arc Welder | Продавец: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Продавец: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |