NES 713 Smoke Toxicity Tester, Toxic Gas Analyzer, Marine Fire Testing Equipment Manufacturer

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Parameters

ParameterSpecification
Flame height 100–125 mm (blue flame)
Maximum hot spot temperature 1150 ± 25 °C
Number of sampling ports 12
Exhaust capacity ≥ 50 L/s
Gas supply Compressed air, methane or natural gas
Power supply AC 220 V, 50/60 Hz, 5 A
Equipment weight Approx. 150 kg
Overall dimensions 1.185 (W) × 700 (D) × 2.100 (H) mm

Features

Rigid steel chamber with reinforced frame construction to ensure long-term structural stability

Large observation window with dark-coated inner walls to clearly observe the combustion behavior of specimens

Inner chamber walls treated with PTFE coating to reduce chemical corrosion caused by combustion gases

Built-in stirring fan to ensure uniform distribution of smoke and combustion gases inside the chamber

Top-mounted exhaust fan with stainless steel exhaust duct, automatically activated after test completion to discharge residual smoke

Integrated industrial design with panel-mounted structure, providing intuitive operation and ergonomic human–machine interface

High-voltage pulse automatic ignition system offering stable ignition performance and enhanced operational safety

Imported K-type thermocouples for accurate and reliable temperature measurement

Adjustable stainless steel specimen mesh tray allowing precise positioning relative to the flame

Imported precision rotameters for accurate control of gas and air flow rates

Branded pressure gauges, pressure regulators, and solenoid valves to control gas pressure and on/off status, ensuring safe operation

PLC and touchscreen control system enabling automatic control, detection, calculation, and data storage

Automatic waste exhaust mode to remove smoke upon test completion according to preset program logic

Manual and automatic test modes selectable to suit different testing requirements

Test Procedures

1. Pre-Test Preparation

Environment confirmation:

The test area should be an independent, well-ventilated space, kept away from flammable materials and densely populated areas. The floor must be dry and free of standing water. The power supply should be properly grounded and meet AC 220 V, 50/60 Hz, 5 A requirements.

Equipment inspection:

Check all gas pipelines (methane or natural gas) for leakage and confirm the gas cylinder pressure is within 0.2–0.3 MPa. Verify that the exhaust fan and stainless steel exhaust duct are unobstructed and capable of providing an exhaust capacity of at least 50 L/s. Confirm normal operation of the K-type thermocouples, rotameters, and PLC touchscreen with no alarm indications. Ensure proper door sealing, intact polycarbonate observation window, and undamaged PTFE inner wall coating.

Safety protection:

Operators should wear high-temperature resistant gloves, safety goggles, gas masks equipped for CO and HCN protection, and safety shoes. A portable multi-gas detector (monitoring O₂, CO, HCN, NOₓ) and an emergency eyewash station should be available on site.

2. Specimen Installation

Specimens should conform to NES 713 requirements, typically measuring 100 mm × 100 mm with a thickness not exceeding 10 mm. Cable materials may be fixed using a coiled arrangement. No more than three specimens should be tested in a single run, evenly distributed on the stainless steel mesh tray to avoid flame obstruction. Adjust the tray position so that it is located directly above the burner, with a distance of 100–125 mm from the burner nozzle to ensure full flame coverage on the specimen underside.

3. Ignition and Test Execution

Close the chamber door and confirm the locking mechanism is engaged. Select “Automatic Mode” on the control screen and start the test. The system will automatically perform high-voltage pulse ignition for approximately three seconds, followed by flame stability detection. If a stable flame is not detected within five seconds, re-ignition will be attempted automatically, up to three times. The combustion process typically lasts 10–15 minutes, during which the internal fan continuously mixes smoke to maintain uniform concentration.

4. Gas Sampling

Gas sampling begins at the fifth minute after ignition and continues until the end of combustion. Twelve dedicated sampling ports are used to connect gas detector tubes (for gases such as HCN, CO, and HCl) or online gas analyzers. Each sampling port is equipped with an independent flow meter, with the sampling flow rate controlled at no more than 1 L/min to avoid negative pressure interference. After sampling, tubes are sealed immediately, labeled with time and port number, and sent for quantitative laboratory analysis.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Aerosol Spray Ignition Tester according to ISO Standards
Aerosol Spray Ignition Tester according to ISO Standards Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Scope of Application and Standards The Foam Aerosol Flammability Tester is d...
Solid Auto - ignition Point Tester
Solid Auto - ignition Point Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com This tester determines the self - ignition characteristics of solid chemical products by pl...
Desktop Xenon lamp aging test chamber
Desktop Xenon lamp aging test chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com TheXenon lamp aging test chamberis a photoaging tester for large-capacity textile testing. ...
Yarn Twist Tester
Yarn Twist Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Yarn Twist Tester is a precision instrument designed to measure the twist level and twi...
Automatic Sock Stretch Recovery System
Automatic Sock Stretch Recovery System Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Sock Stretch Tester is a precision instrument designed to evaluate the el...
Все товары поставщика

Похожие товары

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Продавец: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...