Parameters

ParameterSpecification
Flame height 100–125 mm (blue flame)
Maximum hot spot temperature 1150 ± 25 °C
Number of sampling ports 12
Exhaust capacity ≥ 50 L/s
Gas supply Compressed air, methane or natural gas
Power supply AC 220 V, 50/60 Hz, 5 A
Equipment weight Approx. 150 kg
Overall dimensions 1.185 (W) × 700 (D) × 2.100 (H) mm

Features

Rigid steel chamber with reinforced frame construction to ensure long-term structural stability

Large observation window with dark-coated inner walls to clearly observe the combustion behavior of specimens

Inner chamber walls treated with PTFE coating to reduce chemical corrosion caused by combustion gases

Built-in stirring fan to ensure uniform distribution of smoke and combustion gases inside the chamber

Top-mounted exhaust fan with stainless steel exhaust duct, automatically activated after test completion to discharge residual smoke

Integrated industrial design with panel-mounted structure, providing intuitive operation and ergonomic human–machine interface

High-voltage pulse automatic ignition system offering stable ignition performance and enhanced operational safety

Imported K-type thermocouples for accurate and reliable temperature measurement

Adjustable stainless steel specimen mesh tray allowing precise positioning relative to the flame

Imported precision rotameters for accurate control of gas and air flow rates

Branded pressure gauges, pressure regulators, and solenoid valves to control gas pressure and on/off status, ensuring safe operation

PLC and touchscreen control system enabling automatic control, detection, calculation, and data storage

Automatic waste exhaust mode to remove smoke upon test completion according to preset program logic

Manual and automatic test modes selectable to suit different testing requirements

Test Procedures

1. Pre-Test Preparation

Environment confirmation:

The test area should be an independent, well-ventilated space, kept away from flammable materials and densely populated areas. The floor must be dry and free of standing water. The power supply should be properly grounded and meet AC 220 V, 50/60 Hz, 5 A requirements.

Equipment inspection:

Check all gas pipelines (methane or natural gas) for leakage and confirm the gas cylinder pressure is within 0.2–0.3 MPa. Verify that the exhaust fan and stainless steel exhaust duct are unobstructed and capable of providing an exhaust capacity of at least 50 L/s. Confirm normal operation of the K-type thermocouples, rotameters, and PLC touchscreen with no alarm indications. Ensure proper door sealing, intact polycarbonate observation window, and undamaged PTFE inner wall coating.

Safety protection:

Operators should wear high-temperature resistant gloves, safety goggles, gas masks equipped for CO and HCN protection, and safety shoes. A portable multi-gas detector (monitoring O₂, CO, HCN, NOₓ) and an emergency eyewash station should be available on site.

2. Specimen Installation

Specimens should conform to NES 713 requirements, typically measuring 100 mm × 100 mm with a thickness not exceeding 10 mm. Cable materials may be fixed using a coiled arrangement. No more than three specimens should be tested in a single run, evenly distributed on the stainless steel mesh tray to avoid flame obstruction. Adjust the tray position so that it is located directly above the burner, with a distance of 100–125 mm from the burner nozzle to ensure full flame coverage on the specimen underside.

3. Ignition and Test Execution

Close the chamber door and confirm the locking mechanism is engaged. Select “Automatic Mode” on the control screen and start the test. The system will automatically perform high-voltage pulse ignition for approximately three seconds, followed by flame stability detection. If a stable flame is not detected within five seconds, re-ignition will be attempted automatically, up to three times. The combustion process typically lasts 10–15 minutes, during which the internal fan continuously mixes smoke to maintain uniform concentration.

4. Gas Sampling

Gas sampling begins at the fifth minute after ignition and continues until the end of combustion. Twelve dedicated sampling ports are used to connect gas detector tubes (for gases such as HCN, CO, and HCl) or online gas analyzers. Each sampling port is equipped with an independent flow meter, with the sampling flow rate controlled at no more than 1 L/min to avoid negative pressure interference. After sampling, tubes are sealed immediately, labeled with time and port number, and sent for quantitative laboratory analysis.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Leather softness tester
Leather softness tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Measure the softness of leather and hide to know whether the softness of the same batch of ...
Fabric Fiber Shedding Degree Tester (Friction)
Fabric Fiber Shedding Degree Tester (Friction) Whats/App: +86 156 1874 6768 Web: standard-groups.com The Fabric Fiber Shedding Degree Tester (Friction) is an instrument used to evaluate the li...
 Flame retardant testing machine
Flame retardant testing machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Feature highlights: Flame Retardant Tester is designed for testing plastic runway surface ...
vertical flammability test chamber丨vertical flammability tester
vertical flammability test chamber丨vertical flammability tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Configuration and consumables: AUTOMATIC GAS CONTROL, 230V Automatic Gas Control System ...
Infusion Set Positive Pressure Leakage Tester
Infusion Set Positive Pressure Leakage Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This tester is designed for positive pressure leakage testing of medical infus...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...