Parameters
| Item | Specification |
|---|---|
| Footprint | Determined by actual test requirements |
| Electrical Load | Determined by actual test requirements |
| Heat Release Rate Measurement | Supports up to 20 MW stable combustion tests |
| Gas Analysis | Multi-functional gas analyzers including FTIR, total hydrocarbon analyzers, and sensors |
| Data Acquisition | 300+ temperature channels, 30+ voltage channels, optional 2–8 high-frequency pressure channels |
| Fire Triggering | 4+ heating channels, 8-channel high-voltage spark, 8-channel silicon nitride igniters |
| Monitoring | Thermal imaging infrared cameras, explosion-proof cameras, video recorders, optional high-speed or drone cameras |
| Environmental Monitoring | Temperature, humidity, atmospheric pressure, wind speed, wind direction |
Test Procedures
Site Preparation: Configure the testing area according to fire test requirements and ensure safety systems are in place.
Sample Installation: Mount the energy storage system or container on the movable calorimetric structure.
Environmental Setup: Verify environmental parameters and ensure exhaust systems are operational.
System Configuration: Program data acquisition channels, gas analyzers, and fire triggering devices according to the test plan.
Initiate Fire Test: Trigger external flame attack or internal battery thermal runaway using heating channels, sparks, or igniters.
Real-Time Monitoring: Observe heat release rate, gas composition, smoke opacity, duct parameters, and structural response.
Data Recording: Capture video, thermal imaging, and all sensor data.
Test Completion: Safely extinguish flames, allow cooling, and retrieve test samples. Export data for analysis.
Maintenance Information
Inspect calorimetric structures, fire containment walls, and igniters for integrity before each test.
Maintain exhaust purification units by cleaning water film scrubbers, activated carbon filters, and electric separators regularly.
Calibrate sensors, data acquisition systems, and gas analyzers periodically.
Verify heating channels, spark generators, and igniters for operational readiness.
Backup all acquired data and system logs to ensure traceability and compliance documentation.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| OEM Strength Tester for Lead - end of Photovoltaic Modules | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Strength Tester for Lead-End of Photovoltaic Modules is designed to evalu... | |
| Model Coin-cell Swelling System | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Model Coin-Cell Swelling System is designed for in-situ measurement of thickness and vo... | |
| ASTM & ISO Professional MCD Metal Scratch Tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The MCD Metal Scratch Tester is designed to quantify scratch resistance on me... | |
| Vacuum Ball - Disk Friction Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com A vacuum ball-on-disk friction tester is a device used to simulate friction and wear behavi... | |
| Adjustable nasal oxygen catheter tester instrument | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The nasal oxygen tube tester is mainly used to test key parameters of nasal o... |