High-efficiency filter scanning test bench
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system supports and complies with the following standards:
(1) GB/T 14295-2019 – Air filters.
(2) GB/T 13554-2020 – High-efficiency air filters.
(3) GB/T 6165-2021 – HEPA filter performance: efficiency and resistance.
(4) ISO 29463-4 – HEPA filter leakage testing.
(5) ISO 29463-5 – HEPA filter overall separation efficiency testing.
(6) EN 1822-4 – HEPA filter leakage testing.
(7) EN 1822-5 – HEPA filter overall separation efficiency testing.
(8) ISO 14644-3 – Cleanroom air filtration system testing.
(9) IEST-RP-CC034 – Standardized HEPA and ULPA filter testing.
Parameters
| Parameter | Unit | Value |
|---|---|---|
| Test Flow Rate | m³/h | 120 – 5000 |
| Differential Pressure Measurement | Pa | 1000 |
| Test Sample Dimensions | mm | Max 1830 × 1220 × 300 |
| Aerosol Operating Medium | – | DEHS, PSL |
| Gas/Air Supply | bar | 6 |
| Power Supply | – | 3 × 400 VAC, 100 A |
Features
Fully Automated Filter Scan: Multiple scanning probes enable short test cycles and minimal operator intervention.
Standard-Compliant Test Reports: Automatically generates ISO 29463-4/EN 1822-4 reports.
Flexible Filter Adapter: Accommodates various filter dimensions with quick-change adapters.
User-Friendly Software: STD150Win simplifies control, data acquisition, and analysis.
Accurate Leakage Detection: Particle counters provide precise detection beyond traditional photometers.
Automated Workflow: Reduces manual operations, improves efficiency, and enables real-time results display.
Data Management & Backup: Automatic storage and backup ensure data integrity and traceability.
Remote Access: Supports remote diagnostics, debugging, and calibration.
Accessories
| Accessory | Quantity |
|---|---|
| Filter Media Test Instrument | 1 |
| Filter Adapter | 1 |
| Test System Software | 1 |
Test Principle
Sample Installation: The filter is mounted in the filter holder, ensuring a secure fit.
Aerosol Generation & Flow: Aerosol (DEHS or PSL) is introduced at a controlled volume through the filter.
Leakage and Efficiency Measurement: Downstream particle concentration is measured via particle counters to calculate overall filtration efficiency and identify potential leaks.
Automated Data Collection: PC-controlled software records upstream and downstream particle counts and calculates efficiency and leakage locations.
Operation Instructions
System Startup:
- Configure and start all devices, including aerosol generator, particle counters, and airflow system.
- Install filter adapter according to sample dimensions.
Testing Process:
- Launch test; the system scans the filter using multiple probes, measuring leakage and overall efficiency automatically.
Data Recording & Reporting:
- Software generates a standard-compliant report, including efficiency and leak position.
Experimental Procedure
Preparation Stage:
- Verify all devices are operational.
- Install filter in the appropriate adapter.
Testing Stage:
- System conducts automated scanning and efficiency/leakage measurement.
Result Analysis & Report Generation:
- Test results are automatically compiled and saved in the software, including filter efficiency, potential leaks, and compliance with standards.
Maintenance Information
Regularly clean aerosol generators and scanning probes.
Verify particle counters and sensors for calibration accuracy.
Inspect adapters and seals to prevent leaks affecting measurement.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Digital TPP Calibration Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) BS EN ISO 6942 – Protective clothing – Protection against heat a... | |
| Electrode tortuosity tester & diaphragm ion conductivity tester | The Electrode Tortuosity Tester and Diaphragm Ion Conductivity Tester are precision systems designed for advanced analysis of battery electrodes an... | |
| Humidity Environmental Test Chamber | Features and Benefits 1.Wide Humidity & Temperature Range Offers precise control over humidity from 20% to 98% RH and temperature from -70&de... | |
| Thermal Humidity Chamber | Features and Benefits 1.Avariety of temperature and humidity change modesare supported, such as linear rise cooling/humidity, step jump cooling/hu... | |
| Programmable three-station seat strength testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The machine supports compliance with major international and national standards:... |
Похожие товары
| ISO 29463 HEPA/ULPA filter performance testing System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli... | |
| High-Precision ISO 16890 Filter Media Test Rig for R&D and QC | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com... | |
| ISO 12103 Cleanable Filter Media Test System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| Advanced Vehicle and Aircraft Air Intake Filter Test System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| EN 779 Turbine Filter Test System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... |