High-efficiency filter scanning test bench

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The system supports and complies with the following standards:

(1) GB/T 14295-2019 – Air filters.

(2) GB/T 13554-2020 – High-efficiency air filters.

(3) GB/T 6165-2021 – HEPA filter performance: efficiency and resistance.

(4) ISO 29463-4 – HEPA filter leakage testing.

(5) ISO 29463-5 – HEPA filter overall separation efficiency testing.

(6) EN 1822-4 – HEPA filter leakage testing.

(7) EN 1822-5 – HEPA filter overall separation efficiency testing.

(8) ISO 14644-3 – Cleanroom air filtration system testing.

(9) IEST-RP-CC034 – Standardized HEPA and ULPA filter testing.

Parameters

ParameterUnitValue
Test Flow Rate m³/h 120 – 5000
Differential Pressure Measurement Pa 1000
Test Sample Dimensions mm Max 1830 × 1220 × 300
Aerosol Operating Medium DEHS, PSL
Gas/Air Supply bar 6
Power Supply 3 × 400 VAC, 100 A

Features

Fully Automated Filter Scan: Multiple scanning probes enable short test cycles and minimal operator intervention.

Standard-Compliant Test Reports: Automatically generates ISO 29463-4/EN 1822-4 reports.

Flexible Filter Adapter: Accommodates various filter dimensions with quick-change adapters.

User-Friendly Software: STD150Win simplifies control, data acquisition, and analysis.

Accurate Leakage Detection: Particle counters provide precise detection beyond traditional photometers.

Automated Workflow: Reduces manual operations, improves efficiency, and enables real-time results display.

Data Management & Backup: Automatic storage and backup ensure data integrity and traceability.

Remote Access: Supports remote diagnostics, debugging, and calibration.

Accessories

AccessoryQuantity
Filter Media Test Instrument 1
Filter Adapter 1
Test System Software 1

Test Principle

Sample Installation: The filter is mounted in the filter holder, ensuring a secure fit.

Aerosol Generation & Flow: Aerosol (DEHS or PSL) is introduced at a controlled volume through the filter.

Leakage and Efficiency Measurement: Downstream particle concentration is measured via particle counters to calculate overall filtration efficiency and identify potential leaks.

Automated Data Collection: PC-controlled software records upstream and downstream particle counts and calculates efficiency and leakage locations.

Operation Instructions

System Startup:

- Configure and start all devices, including aerosol generator, particle counters, and airflow system.

- Install filter adapter according to sample dimensions.

Testing Process:

- Launch test; the system scans the filter using multiple probes, measuring leakage and overall efficiency automatically.

Data Recording & Reporting:

- Software generates a standard-compliant report, including efficiency and leak position.

Experimental Procedure

Preparation Stage:

- Verify all devices are operational.

- Install filter in the appropriate adapter.

Testing Stage:

- System conducts automated scanning and efficiency/leakage measurement.

Result Analysis & Report Generation:

- Test results are automatically compiled and saved in the software, including filter efficiency, potential leaks, and compliance with standards.

Maintenance Information

Regularly clean aerosol generators and scanning probes.

Verify particle counters and sensors for calibration accuracy.

Inspect adapters and seals to prevent leaks affecting measurement.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Surface Performance Tester STD-FB4-A,flexible material surface performance tester
Surface Performance Tester STD-FB4-A,flexible material surface performance tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Surface Performance Tester is a high-precision instrument designed to quantify the surf...
Sponge foam collapsible hardness meter
Sponge foam collapsible hardness meter Whats/App: +86 156 1874 6768 Web: standard-groups.com Purpose: This machine is used to measure the indentation hardness of porous elastic materi...
STD Battery short-circuit tester丨STD Battery short-circuit chamber
STD Battery short-circuit tester丨STD Battery short-circuit chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction Battery Short Circuit Tester is a device that can be applied to the e...
Battery Abuse Testing Chamber Manufacturer | UN38.3, IEC 62133 & UL 1642 Battery Safety Test Equipment
Battery Abuse Testing Chamber Manufacturer | UN38.3, IEC 62133 & UL 1642 Battery Safety Test Equipment Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Parameters ItemSpecification Wor...
Textile far-infrared radiation temperature rise test instrument
Textile far-infrared radiation temperature rise test instrument Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Textile Far Infrared Radiation Temperature Rise Tester is used for various te...
All supplier products

Same products

Filter Efficiency Testing Equipment
Filter Efficiency Testing Equipment Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com TheFilter Efficiency Testing Equipmentis ...
G506 Filter Performance Tester
G506 Filter Performance Tester Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM F2100:Standard Specificat...
Automated Filter Integrity Tester
Automated Filter Integrity Tester Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Testing Standards ASTM F838 – Memb...
High Efficiency Oil Water Separation Tester
High Efficiency Oil Water Separation Tester Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO/TS 16332-2006 – Meth...
DIN 51524 hydraulic oil analyzer
DIN 51524 hydraulic oil analyzer Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards You can operate this unit in c...