Custom Cabin Air Filter Gas Adsorption Testing Apparatus
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
(1) GB/T 32085.2-2015 — Automotive Air Conditioning Filters, Part 2: Gas Filtration Test
(2) DIN 71460-2 — Road Vehicles — Cabin Air Filters, Part 2: Gas Filtration Test
(3) ISO 11155-2:2009 — Road Vehicles — In-Cabin Air Filters, Part 2
(4) ISO 10121-1 / ISO 10121-2 — General Methods for Testing Air Filter Performance
Features
standard compliant testing of filter elements and filter mediaoperator is guided through test routines
modular system and instrumentation
versatile
Technical Data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | m³/h | 70 … 700 |
| Measuring range, differential pressure | Pa | 0 … 1000 |
| Test gases | – | n-Butane 80 ppm (C₄H₁₀), Toluene 80 ppm (C₆H₅CH₃), Sulphur dioxide 30 ppm (SO₂), Ammonia 30 ppm (NH₃), Nitrogen (purging) |
| Power supply | – | 3 × 230 VAC, 16 A |
| Test specimen dimensions | mm | max. 300 × 600 |
| Gas analysers | – | Hydrocarbons with FID, Sulfur oxides with NDIR, Nitrogen oxides with CLD |
| Sensors (others) | – | Temperature, relative humidity, absolute pressure |
| System dimensions (W × H × D) | mm | 1800 × 2500 × 1100 |
Accessories
test channel and rig
gas dosing system
exhaust system
flowmeter
gas analyser
sensors
test stand control software
Principle
Integral parts of test procedures
- Differential-Pressure measurement
- Adsortion tests according standard ISO 11155-2 (DIN 71460-2)
- Adsorption/Desorption measurement
- user-defined test procedures
Maintenance Information
Regularly calibrate gas analyzers and flow meters to maintain accuracy.
Inspect seals, adapters, and tubing for leaks before each test.
Clean and maintain the gas dosing and exhaust systems according to manufacturer instructions.
Replace consumables, such as filters and gas lines, as required.
Ensure software and firmware are up to date for accurate data acquisition and analysis.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Environment Controlled Chamber | Features and Benefits 1.Accurately control the temperature, humidity and other environmental parameters. Other environmental factors can also be c... | |
| High Velocity Impact Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main Purpose To test the impact - resistance performance of glasses, goggles and face shie... | |
| Nbs Smoke Density Chamber, ASTM E662, ISO 5659,optical density smoke analyzer for plastics | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction The main principle is to measure smoke density in a particular space, cable o... | |
| Absorbable Bone - connecting Plates Four - point Bending Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM F2119: Standard test method for constant load testing of bioabsorbable scr... | |
| Textile Fiber Composition Analyzer tester | Standard ASTM D276(Standard Test Method for Identification of Fibers in Textiles) ISO 1833(Determination of Fiber Content in Textiles) AATCC 2... |
Похожие товары
| ISO 29463 HEPA/ULPA filter performance testing System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli... | |
| High-Precision ISO 16890 Filter Media Test Rig for R&D and QC | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com... | |
| ISO 12103 Cleanable Filter Media Test System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| Advanced Vehicle and Aircraft Air Intake Filter Test System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| EN 779 Turbine Filter Test System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... |