Cooling Water Chiller SUNDI -45℃~300℃
It is important to choose the suitable heat conduction medium, to make sure that system works stably. To choose the suitable medium according to the working temperature of the system is essential.
How to Determine Freezing Water Flow Rate?
A lot of people will ask such a question when they buy a cold water machine -- how do you determine the freezing water flow of a refrigerated water unit? So which aspects should we consider the cold water flow?
Detect the pressure value of the in- and out-water, then refer to instruction about the water flow under this circumstance and determine whether the water system is normal by looking at the description in the corresponding table or flow diagram of the unit. This difference is also used to determine which part of the water pipeline has a large resistance and make corresponding rectification plan and action.
If the temperature of the is tested lower than zero after running for 30 minutes, then water flow is not enough on water side heat exchanger which causes evaporation temperature and pressure to fall and cause freon in evaporator flow to the compressor suction duct in evaporation heat. That brings about the fact that the compressor suction temperature below zero. In addition, the evaporation pressure and evaporation temperature caused by low temperature setting should be excluded. However, the low-temperature unit can be considered normal as long as there is 6 ~ 8 ℃ overheat of compressor suction. So under normal water flow, the compressor suction temperature generally will be greater than 0 ℃. Temperature lower than this value should be ruled out water system problems.
By detecting the current of the pump of water and comparing with rated current, you can determine the actual water flow, whether its water flow is big or small. Refer to the parameters above, you can draw an exact water system testing analysis report.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Low Temperature Chiller LN -60℃~-10℃ | We know that thelow temp process chillersare complicated equipment. Even the switch process, if not according to the standard of operation or with ... | |
| Extraction process chiller CDLJ -115℃~-50℃ | Medium-sized low-temperature freezer, refrigeration temperature range from -155℃ ~ -50℃, safe, reliable, rapid cooling for the liquid, widely used ... | |
| Semiconductor Temperature Controlled Circulating Air System | Temperature control range:-85 ° C ~ 125 ° C Power range:3.5kW~10kW Temperature control accuracy:±0.2°C Applications: 3, can work... | |
| Test Chamber | Room environment refers to simulate natural climate environment in the space of valid range test types are: high and low temperature test box, high... | |
| Dynamic Temperature Control Systems | Thechiller temperature controllerof the dynamic temperature control system is completed by the single chip microcomputer, and the digital PID con... |
Похожие товары
| Large Condensing Hot Water Unit | Продавец: Hebei Qintai Thermal Power Equipment Co., Ltd | Large Condensing Hot Water Unit Gas-Fired Hot-Water HeaterProduct Advantages: (1) Using large-s... | |
| Fully Premixed Condensate Hot Water System | Продавец: Hebei Qintai Thermal Power Equipment Co., Ltd | Fully Premixed Condensate Hot Water System The burner used in the equipment adopts the self-deve... | |
| Fully Premixed Condensate Hot Water System | Продавец: Hebei Qintai Thermal Power Equipment Co., Ltd | Fully Premixed Condensate Hot Water System Thisgas-steam thermal generator, combining these tech... | |
| Fully Premixed Gas-Fired Steam Generator-Smart Version | Продавец: Hebei Qintai Thermal Power Equipment Co., Ltd | Fully Premixed Gas-Fired Steam Generator-Smart Version Discover the Smart Version of Qintai&rsqu... | |
| Undercounter Refrigerator Manufacturer | Продавец: Guangzhou Suiling Appliance Co.,LTD. | Undercounter Refrigerator Manufacturer Why Choose Our Undercounter Refrigerators? ... |