Cooling Water Chiller SUNDI -45℃~300℃
It is important to choose the suitable heat conduction medium, to make sure that system works stably. To choose the suitable medium according to the working temperature of the system is essential.
How to Determine Freezing Water Flow Rate?
A lot of people will ask such a question when they buy a cold water machine -- how do you determine the freezing water flow of a refrigerated water unit? So which aspects should we consider the cold water flow?
Detect the pressure value of the in- and out-water, then refer to instruction about the water flow under this circumstance and determine whether the water system is normal by looking at the description in the corresponding table or flow diagram of the unit. This difference is also used to determine which part of the water pipeline has a large resistance and make corresponding rectification plan and action.
If the temperature of the is tested lower than zero after running for 30 minutes, then water flow is not enough on water side heat exchanger which causes evaporation temperature and pressure to fall and cause freon in evaporator flow to the compressor suction duct in evaporation heat. That brings about the fact that the compressor suction temperature below zero. In addition, the evaporation pressure and evaporation temperature caused by low temperature setting should be excluded. However, the low-temperature unit can be considered normal as long as there is 6 ~ 8 ℃ overheat of compressor suction. So under normal water flow, the compressor suction temperature generally will be greater than 0 ℃. Temperature lower than this value should be ruled out water system problems.
By detecting the current of the pump of water and comparing with rated current, you can determine the actual water flow, whether its water flow is big or small. Refer to the parameters above, you can draw an exact water system testing analysis report.
Send product request
Other supplier products
| Ultra Low Temperature Recirculating Chillers LC -25℃~-5℃ | -25℃~-5℃ Technical Parameters: Medium-sized low-temperature freezer/ultra low temperature recirculating chillers, refrigeration temperature range... | |
| Lab Water Chiller SUNDI -60℃~300℃ | SUNDI -60℃~300℃ A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for the thermal fluid utilization whil... | |
| Thermal Shock Test Chamber | High and low temperature impact chamber is a necessary test equipment of material such as metal, plastic, rubber, electronics and so on, used for t... | |
| Lab Water Chiller SUNDI -60℃~300℃ | Laboratory Water ChillerSUNDI -60℃~300℃ -60℃~300℃ A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand f... | |
| Glycol Cooling Heating Control System | Application: The tested object is attached to a test platform adapter. The inside of the part was cooled and heated by an aqueous solution of ethyl... |
Same products
| PanPHE gasketed plate heat exchangers | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanPHE gasketed plate heat exchangersare designed with easy access for regular servicing and for ... | |
| Large Condensing Hot Water Unit | Seller: Hebei Qintai Thermal Power Equipment Co., Ltd | Large Condensing Hot Water Unit Gas-Fired Hot-Water HeaterProduct Advantages: (1) Using large-s... | |
| Fully Premixed Condensate Hot Water System | Seller: Hebei Qintai Thermal Power Equipment Co., Ltd | Fully Premixed Condensate Hot Water System The burner used in the equipment adopts the self-deve... | |
| Fully Premixed Condensate Hot Water System | Seller: Hebei Qintai Thermal Power Equipment Co., Ltd | Fully Premixed Condensate Hot Water System Thisgas-steam thermal generator, combining these tech... | |
| Fully Premixed Gas-Fired Steam Generator-Smart Version | Seller: Hebei Qintai Thermal Power Equipment Co., Ltd | Fully Premixed Gas-Fired Steam Generator-Smart Version Discover the Smart Version of Qintai&rsqu... |