.

Coronary Stents

Types of Coronary Stents

NeoVas™ Sirolimus-eluting Bioresorbable Coronary Stent System

NeoVas™

From Recanalization to Revascularization

New Era Toward“BIORESORBABLE times

NeoVas™ Sirolimus-eluting Bioresorbable Coronary Stent System Details

Product Description

Stent Platform

Fully degradable poly(L-lactide)

Sine wave structure in space, In-phase peak-valley connection

Drug coating

Fully degradable poly(D,L-lactide)

Effectively control sirolimus release rate

Drug

Classical Sirolimus with dose of 15.3ug/mm

Inhibit the proliferation and migration of smooth muscle cells

Delivery system

Completely self-developed second-generation rapid-exchange balloon dilatation catheter

Superior pushability and crossability

NeoVas RCT Study

The study enrolled 560 subjects in 33 centers from China, Test group(NeoVas): 278 cases, Control group (Xience stent): 282 cases.

Primary endpoint: the late lumen loss in one year follow-up

Conclusion:

The clinical events rate for Neovas bioabsorbable stent is low, showed equal safety and effectiveness with Xience metal stent.

NeoVas OPC study

The study enrolled 1103 subjects in 45 centers from China, two year clinical follow-up study has been completed to date.

1-2 year follow-up result

Conclusion:

2-year follow up Clinical results for 1103 subjects demonstrate that NeoVas bioresorbable stent has equal low clinical events rate. Compared with the first generation bioresorbable stent Absorb BVS, the clinical events rate has been obviously decreased, and it indicates that NeoVas performed favorable safety and effectiveness.

The Imaging study of the NeoVas Subgroup

The subgroup analyzed the imaging and function of 166 subjects from the randomized controlled study, 83 cases for test/control group.

Conclusion:

NeoVas subgroup of 3 years clinical imaging data shows vessel vasomotor function has been restored after 3 years implantation, superior to metal stent. Blood supply keeps at favorable level. Most stent was degraded and absorbed after 3 years.

The importance of standardized PSP operations

Tips: Absorb BVS did not perform standard PSP operation and increased the safty incident

The Absorb Ⅱ/Ⅲ study shows that the safty incident of TLF and stent thrombus was significantly increased and has statistical difference with metal stent due to the failure to perform PSP operation.

Sirolimus Eluting Stent

The TLF and stent thrombus of patient using PSP and without using PSP operation in Absorb Ⅲ study

Experience: Standardized PSP operation ensures safety for Neovas Stent

The application rate of PSP operation is relatively low in Absorb Ⅱ and Absorb Ⅲ study, the TLF and stent thrombus of BVS in three years is relatively high, displays statistical difference with metal stent; the PSP operation perform rate in Absorb China study is relatively high, the TLF and stent thrombus of BVS in three years is relatively low and has no statistical difference with metal stent.

Sirolimus Stent

Comparison of stent thrombus (ST) and TLF at three years in Absorb BVS clinical study Stent thrombus (ST) and TLF at three years for NeoVas clinical study.

In Neovas clinical study, with standardized PSP operation, the TLF and ST in three years has no statistical difference. Strictly PSP operation performing is critical to significantly decrease stent adverse cardiac events.

Why PSP operation significantly decrease adverse cardiac events?

The direct reason of stent long-term adverse cardiac events (stent thrombus) is the stent malap- position during implantation. Stent malapposition will cause micro vascular dissection. For metal stent, stable new vessel wall will be formed after revascularization and endothelialization supported by metal stent. For bioresorbable stent, this vessel wall is unstable due to the stent degradation. Stent even breaks at thin endothelializaton tissue area and leads to the direct connection between blood and micro vascular dissection, this will cause stent thrombus rate increased higher compared with metal stent.

The objects of the regulated PSP operation is to ensure the stent apposition and exclude the vascular dissection.

Sirolimus-eluting Bioresorbable Coronary Stent System.

First brand launched in China.

Nano+™ Polymer-free Sirolimus-eluting Coronary Stent System

Nothing Beats Free

GuReater<sup>®</sup>CoCr Stent Sirolimus-eluting Coronary Stent System

GuReater®CoCr Stent Sirolimus-eluting Coronary Stent System

CoCr Stent Sirolimus-eluting Coronary Stent System

Partner<sup>®</sup>Sirolimus-eluting Coronary Stent System

Partner®Sirolimus-eluting Coronary Stent System

Sirolimus-eluting Coronary Stent System.

Classical stainless steel stent.

H-Stent™ Coronary Stent System

Coronary Stent System

As one of medical equipment manufacturers in china, we can offer sorts of medical devices chinafor sale with reasonable prices, if you are interested, please leave us a message.


Отправить запрос, связаться с поставщиком

Кому: Lepu Medical Technology(Beijing)Co.,Ltd
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

PC-60NW Fingertip Oximeter (Wireless)
PC-60NW Fingertip Oximeter (Wireless) Features OLE D displays with auto-rotation in 4-direction SpO2, PR, PI, Pulse bar and waveform Applicable to adult, pediatric and neonate with ...
LF05A Oxygen Generator
LF05A Oxygen Generator Large-screen display Built-in water tank Remote control With an atomizing function Up to 11 alarm items Hidden oxygen/atomizing nozzle, which ...
SARS-CoV-2 Antibody Test Kit (Colloidal Gold Immunochromatography)
SARS-CoV-2 Antibody Test Kit (Colloidal Gold Immunochromatography) Accurate: High-purity antibody with high accuracy Efficient: Test result is available in 15mins Convenient: Suitable for finger blood Plea...
Disposable Bloodlines and Fistula Needles
Disposable Bloodlines and Fistula Needles Disposable Bloodlines and Fistula NeedlesDetails Disposable Bloodlines Features Double-layer design: • Medical TPU inner layer: benefit d...
Disposable Clip Applier
Disposable Clip Applier Occlude blood vessel and other tissue structures in the endoscopic surgery. Up to 20 titanium clips hit continuously. Used in small incision ...
Все товары поставщика

Похожие товары

Prophy Brush(hard/soft)
Prophy Brush(hard/soft) Продавец: Huanghua Promisee Dental Co.,Ltd Prophy Brush(hard/soft) Product Description Prophy Brushis composed of a metal handle and a wor...
Micro Applicator(Ultrathin)
Micro Applicator(Ultrathin) Продавец: Huanghua Promisee Dental Co.,Ltd Micro Applicator(Ultrathin) Product Description Micro applicator bulk pack supplieroffering 100...
Dental Retractor(M type)
Dental Retractor(M type) Продавец: Huanghua Promisee Dental Co.,Ltd Dental Retractor(M type) Product Description ThisDental Retractor(M type)is M type design. In o...
Dental Dam Kit
Dental Dam Kit Продавец: Huanghua Promisee Dental Co.,Ltd Dental Dam Kit Product Description The Dental Dam Kit, a type of disposable dental supplies, is...
Electromagnetic Flow Meter
Electromagnetic Flow Meter Продавец: Beijing Gallop High& New Tech Co.,Ltd Electromagnetic flow meter, a type ofindustrial instrumentation, is one of the oldest and most wi...