.

Coronary Stents

Types of Coronary Stents

NeoVas™ Sirolimus-eluting Bioresorbable Coronary Stent System

NeoVas™

From Recanalization to Revascularization

New Era Toward“BIORESORBABLE times

NeoVas™ Sirolimus-eluting Bioresorbable Coronary Stent System Details

Product Description

Stent Platform

Fully degradable poly(L-lactide)

Sine wave structure in space, In-phase peak-valley connection

Drug coating

Fully degradable poly(D,L-lactide)

Effectively control sirolimus release rate

Drug

Classical Sirolimus with dose of 15.3ug/mm

Inhibit the proliferation and migration of smooth muscle cells

Delivery system

Completely self-developed second-generation rapid-exchange balloon dilatation catheter

Superior pushability and crossability

NeoVas RCT Study

The study enrolled 560 subjects in 33 centers from China, Test group(NeoVas): 278 cases, Control group (Xience stent): 282 cases.

Primary endpoint: the late lumen loss in one year follow-up

Conclusion:

The clinical events rate for Neovas bioabsorbable stent is low, showed equal safety and effectiveness with Xience metal stent.

NeoVas OPC study

The study enrolled 1103 subjects in 45 centers from China, two year clinical follow-up study has been completed to date.

1-2 year follow-up result

Conclusion:

2-year follow up Clinical results for 1103 subjects demonstrate that NeoVas bioresorbable stent has equal low clinical events rate. Compared with the first generation bioresorbable stent Absorb BVS, the clinical events rate has been obviously decreased, and it indicates that NeoVas performed favorable safety and effectiveness.

The Imaging study of the NeoVas Subgroup

The subgroup analyzed the imaging and function of 166 subjects from the randomized controlled study, 83 cases for test/control group.

Conclusion:

NeoVas subgroup of 3 years clinical imaging data shows vessel vasomotor function has been restored after 3 years implantation, superior to metal stent. Blood supply keeps at favorable level. Most stent was degraded and absorbed after 3 years.

The importance of standardized PSP operations

Tips: Absorb BVS did not perform standard PSP operation and increased the safty incident

The Absorb Ⅱ/Ⅲ study shows that the safty incident of TLF and stent thrombus was significantly increased and has statistical difference with metal stent due to the failure to perform PSP operation.

Sirolimus Eluting Stent

The TLF and stent thrombus of patient using PSP and without using PSP operation in Absorb Ⅲ study

Experience: Standardized PSP operation ensures safety for Neovas Stent

The application rate of PSP operation is relatively low in Absorb Ⅱ and Absorb Ⅲ study, the TLF and stent thrombus of BVS in three years is relatively high, displays statistical difference with metal stent; the PSP operation perform rate in Absorb China study is relatively high, the TLF and stent thrombus of BVS in three years is relatively low and has no statistical difference with metal stent.

Sirolimus Stent

Comparison of stent thrombus (ST) and TLF at three years in Absorb BVS clinical study Stent thrombus (ST) and TLF at three years for NeoVas clinical study.

In Neovas clinical study, with standardized PSP operation, the TLF and ST in three years has no statistical difference. Strictly PSP operation performing is critical to significantly decrease stent adverse cardiac events.

Why PSP operation significantly decrease adverse cardiac events?

The direct reason of stent long-term adverse cardiac events (stent thrombus) is the stent malap- position during implantation. Stent malapposition will cause micro vascular dissection. For metal stent, stable new vessel wall will be formed after revascularization and endothelialization supported by metal stent. For bioresorbable stent, this vessel wall is unstable due to the stent degradation. Stent even breaks at thin endothelializaton tissue area and leads to the direct connection between blood and micro vascular dissection, this will cause stent thrombus rate increased higher compared with metal stent.

The objects of the regulated PSP operation is to ensure the stent apposition and exclude the vascular dissection.

Sirolimus-eluting Bioresorbable Coronary Stent System.

First brand launched in China.

Nano+™ Polymer-free Sirolimus-eluting Coronary Stent System

Nothing Beats Free

GuReater<sup>®</sup>CoCr Stent Sirolimus-eluting Coronary Stent System

GuReater®CoCr Stent Sirolimus-eluting Coronary Stent System

CoCr Stent Sirolimus-eluting Coronary Stent System

Partner<sup>®</sup>Sirolimus-eluting Coronary Stent System

Partner®Sirolimus-eluting Coronary Stent System

Sirolimus-eluting Coronary Stent System.

Classical stainless steel stent.

H-Stent™ Coronary Stent System

Coronary Stent System

As one of medical equipment manufacturers in china, we can offer sorts of medical devices chinafor sale with reasonable prices, if you are interested, please leave us a message.


Отправить запрос, связаться с поставщиком

Кому: Lepu Medical Technology(Beijing)Co.,Ltd
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

GuReater®CoCr Stent Sirolimus-eluting Coronary Stent System
GuReater®CoCr Stent Sirolimus-eluting Coronary Stent System To develop LepuMedical into one of the largest cardiovascular products manufacturersand on the platforms of medical device, medicine, healthcare pr...
Pazopanib
Pazopanib LepuMedical Technology ( Beijing ) Co., Ltd is a professional pazopanib manufacturer, we provide lepu thermometer, nebulizer machine for kids, ruca...
Disposable Endo Retrieval Bag
Disposable Endo Retrieval Bag Disposable Endo Retrieval Bag Application: Suitable for minimally invasive surgery to remove the excisional diseased tissue from the body. Typ...
Clopidogrel Bisulfate
Clopidogrel Bisulfate Clopidogrel Hydrogen Sulfate Item/Code CAS No. Molecular Structure Therapeutic Area Certification/Stage API ...
Equipments
Equipments Featured Dual Chamber Pacing System Programmer and Dual Chamber Pacing System Analyzer Types of Pacemaker equipment Dual Chamber Pacing System ...
Все товары поставщика

Похожие товары

Disposable Syringe Suppliers
Disposable Syringe Suppliers Продавец: 866413 Zhejiang INI Medical Devices Co., Ltd. has specialized in sterile medical devic...
Sodium Deoxycholate Powder
Sodium Deoxycholate Powder Продавец: CHENGDU CHENLV HERB CO.,LTD. Sodium Deoxycholate Powder Sodium Deoxycholate Powder — Reliable Manufacturer & Suppli...
Instant Tea Powder
Instant Tea Powder Продавец: CHENGDU CHENLV HERB CO.,LTD. Instant Tea Powder Instant Tea Powder Manufacturer for Beverage & OEM Applications As an ex...
Matcha Tea Powder
Matcha Tea Powder Продавец: CHENGDU CHENLV HERB CO.,LTD. Matcha Tea Powder Matcha Tea Powder Supplier for Beverage & Food Applications As a professi...
Tea Extracts
Tea Extracts Продавец: CHENGDU CHENLV HERB CO.,LTD. Tea Extracts Tea Extracts Supplier for Beverage, Supplement & Industrial Applications As a ...