.

Coronary Stents

Types of Coronary Stents

NeoVas™ Sirolimus-eluting Bioresorbable Coronary Stent System

NeoVas™

From Recanalization to Revascularization

New Era Toward“BIORESORBABLE times

NeoVas™ Sirolimus-eluting Bioresorbable Coronary Stent System Details

Product Description

Stent Platform

Fully degradable poly(L-lactide)

Sine wave structure in space, In-phase peak-valley connection

Drug coating

Fully degradable poly(D,L-lactide)

Effectively control sirolimus release rate

Drug

Classical Sirolimus with dose of 15.3ug/mm

Inhibit the proliferation and migration of smooth muscle cells

Delivery system

Completely self-developed second-generation rapid-exchange balloon dilatation catheter

Superior pushability and crossability

NeoVas RCT Study

The study enrolled 560 subjects in 33 centers from China, Test group(NeoVas): 278 cases, Control group (Xience stent): 282 cases.

Primary endpoint: the late lumen loss in one year follow-up

Conclusion:

The clinical events rate for Neovas bioabsorbable stent is low, showed equal safety and effectiveness with Xience metal stent.

NeoVas OPC study

The study enrolled 1103 subjects in 45 centers from China, two year clinical follow-up study has been completed to date.

1-2 year follow-up result

Conclusion:

2-year follow up Clinical results for 1103 subjects demonstrate that NeoVas bioresorbable stent has equal low clinical events rate. Compared with the first generation bioresorbable stent Absorb BVS, the clinical events rate has been obviously decreased, and it indicates that NeoVas performed favorable safety and effectiveness.

The Imaging study of the NeoVas Subgroup

The subgroup analyzed the imaging and function of 166 subjects from the randomized controlled study, 83 cases for test/control group.

Conclusion:

NeoVas subgroup of 3 years clinical imaging data shows vessel vasomotor function has been restored after 3 years implantation, superior to metal stent. Blood supply keeps at favorable level. Most stent was degraded and absorbed after 3 years.

The importance of standardized PSP operations

Tips: Absorb BVS did not perform standard PSP operation and increased the safty incident

The Absorb Ⅱ/Ⅲ study shows that the safty incident of TLF and stent thrombus was significantly increased and has statistical difference with metal stent due to the failure to perform PSP operation.

Sirolimus Eluting Stent

The TLF and stent thrombus of patient using PSP and without using PSP operation in Absorb Ⅲ study

Experience: Standardized PSP operation ensures safety for Neovas Stent

The application rate of PSP operation is relatively low in Absorb Ⅱ and Absorb Ⅲ study, the TLF and stent thrombus of BVS in three years is relatively high, displays statistical difference with metal stent; the PSP operation perform rate in Absorb China study is relatively high, the TLF and stent thrombus of BVS in three years is relatively low and has no statistical difference with metal stent.

Sirolimus Stent

Comparison of stent thrombus (ST) and TLF at three years in Absorb BVS clinical study Stent thrombus (ST) and TLF at three years for NeoVas clinical study.

In Neovas clinical study, with standardized PSP operation, the TLF and ST in three years has no statistical difference. Strictly PSP operation performing is critical to significantly decrease stent adverse cardiac events.

Why PSP operation significantly decrease adverse cardiac events?

The direct reason of stent long-term adverse cardiac events (stent thrombus) is the stent malap- position during implantation. Stent malapposition will cause micro vascular dissection. For metal stent, stable new vessel wall will be formed after revascularization and endothelialization supported by metal stent. For bioresorbable stent, this vessel wall is unstable due to the stent degradation. Stent even breaks at thin endothelializaton tissue area and leads to the direct connection between blood and micro vascular dissection, this will cause stent thrombus rate increased higher compared with metal stent.

The objects of the regulated PSP operation is to ensure the stent apposition and exclude the vascular dissection.

Sirolimus-eluting Bioresorbable Coronary Stent System.

First brand launched in China.

Nano+™ Polymer-free Sirolimus-eluting Coronary Stent System

Nothing Beats Free

GuReater<sup>®</sup>CoCr Stent Sirolimus-eluting Coronary Stent System

GuReater®CoCr Stent Sirolimus-eluting Coronary Stent System

CoCr Stent Sirolimus-eluting Coronary Stent System

Partner<sup>®</sup>Sirolimus-eluting Coronary Stent System

Partner®Sirolimus-eluting Coronary Stent System

Sirolimus-eluting Coronary Stent System.

Classical stainless steel stent.

H-Stent™ Coronary Stent System

Coronary Stent System

As one of medical equipment manufacturers in china, we can offer sorts of medical devices chinafor sale with reasonable prices, if you are interested, please leave us a message.



在线联系供应商

至: Lepu Medical Technology(Beijing)Co.,Ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Coronary Stents
Coronary Stents Types of Coronary Stents NeoVas™ Sirolimus-eluting Bioresorbable Coronary Stent System NeoVas™ From Recanalization to Revascularizat...
Deliver™ Infusion Catheter
Deliver™ Infusion Catheter Deliver™ Infusion Catheter Deliver™ Infusion CatheterDetails Combined liquid perfusion lumen and guide wire lumen fulfills the per...
Perdenser® Embolic Coil System
Perdenser® Embolic Coil System Embolic Coil. Neurovascular medical device. Applied for endovascular embolization. Perdenser® Embolic CoilSystem Details Perdenser® Emb...
Linezolid
Linezolid Item/Code CAS No. Molecular Structure Therapeutic Area Certification/Stage Linezolid Antibiotics USA - USDMF No.26962 EU ...
Linezolid
Linezolid *Product registration and availability vary by country. For more information on product availability, please contact us here. As a professional ...
供应产品

Same products

Blue Non-Woven Fabric Silicone Gel Tape Roll for Scar Treatment
Blue Non-Woven Fabric Silicone Gel Tape Roll for Scar Treatment 卖方: Zhejiang Hangbiao Medical Supplies Co., Ltd. Surgical Tape Factory() Blue Non-Woven Fabric Silicone Gel Tape Roll is a premium scar repair pro...
MECHANIC MEC 4K 2K 高清电子目镜相机,适用于立体显微镜
MECHANIC MEC 4K 2K 高清电子目镜相机,适用于立体显微镜 卖方: 深圳市维客修科技有限公司 描述 美卡尼克MEC 2K/2K PRO/4K高清电子目镜摄像机,可以将双目立体显微镜改装成三目显微镜。采用SONY 1/2.3"进口CMOS传感器,采用优质CMOS传感器,硬...
Fluke 15B+ 17B+ 18B+ 数字万用表电压频率测试仪
Fluke 15B+ 17B+ 18B+ 数字万用表电压频率测试仪 卖方: 深圳市维客修科技有限公司 iFixes 10CC半透明/全透明/乳白色/浅无铅助焊膏适用于手机主板CPU BGA维修。iFixes助焊剂注射器注射焊膏焊接膏手机整理焊接耗材系列,适用于电路板纳米芯片,手机PCB, SMT...
Grey Rubber Stopper For Blood Collection Tube
Grey Rubber Stopper For Blood Collection Tube 卖方: Taizhou KangLong Medical Treatment Technology Co., Ltd. Medical Grey Rubber Stopper For Blood Collection Tube Good formulation technology guarantees...
HTT-02 Hot Tack Tester
HTT-02 Hot Tack Tester 卖方: Cell Instruments Co., Ltd The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren...