Polypectomy Snares (Hot)
This device indicated for use endoscopically for the removal of polyps.
Features of Polypectomy Snares (Hot)
Snares are available in multiple shapes, stiffness ranging from 'soft' to 'Hard', as well as full range snare open width to meet different polyps cutting requirement.
Braided wires for excellent coagulation and bleeding control.
360° 1:1 rotation for precise adjustment.
Specification of Polypectomy Snares (Hot)
Rgeular items
|
REF |
Catheter |
Snare |
Stiffness |
Units/Box |
|||
|
Fixed |
Rotatable |
Catheter Diam. (mm) |
Working length (mm) |
Opening Width (mm) |
Configuration |
||
|
L16CA241815A0 |
L16RA241815A0 |
1800 |
15 |
Oval |
Soft |
10 |
|
|
L16CA241825A0 |
L16RA241825A0 |
1800 |
25 |
||||
|
L16CA241832A0 |
L16RA241832A0 |
1800 |
32 |
||||
|
L16CA242415A0 |
L16RA242415A0 |
2400 |
15 |
||||
|
L16CA242425A0 |
L16RA242425A0 |
2400 |
25 |
||||
|
L16CA242432A0 |
L16RA242432A0 |
2400 |
32 |
||||
|
L16CB241822A0 |
L16RB241822A0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832A0 |
L16RB241832A0 |
1800 |
32 |
||||
|
L16CB242422A0 |
L16RB242422A0 |
2400 |
22 |
||||
|
L16CB242432A0 |
L16RB242432A0 |
2400 |
32 |
||||
|
L16CC241825A0 |
L16RC241825A0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832A0 |
L16RC241832A0 |
1800 |
32 |
||||
|
L16CC242425A0 |
L16RC242425A0 |
2400 |
25 |
||||
|
L16CC242432A0 |
L16RC242432A0 |
2400 |
32 |
||||
|
L16CA241815B0 |
L16RA241815B0 |
1800 |
15 |
Oval |
Hard |
||
|
L16CA241825B0 |
L16RA241825B0 |
1800 |
25 |
||||
|
L16CA241832B0 |
L16RA241832B0 |
1800 |
32 |
||||
|
L16CA242415B0 |
L16RA242415B0 |
2400 |
15 |
||||
|
L16CA242425B0 |
L16RA242425B0 |
2400 |
25 |
||||
|
L16CA242432B0 |
L16RA242432B0 |
2400 |
32 |
||||
|
L16CB241822B0 |
L16RB241822B0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832B0 |
L16RB241832B0 |
1800 |
32 |
||||
|
L16CB242422B0 |
L16RB242422B0 |
2400 |
22 |
||||
|
L16CB242432B0 |
L16RB242432B0 |
2400 |
32 |
||||
|
L16CC241825B0 |
L16RC241825B0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832B0 |
L16RC241832B0 |
1800 |
32 |
||||
|
L16CC242425B0 |
L16RC242425B0 |
2400 |
25 |
||||
|
L16CC242432B0 |
L16RC242432B0 |
2400 |
32 |
||||
What is a Hot Snare Polypectomy
Hot snare polypectomy, the endoscopist advances the snare sheath, opens the snare and encircles the polyp. The snare is then slowly and progressively closed, with the aim of capturing 1-2 mm of normal tissue around the polyp,then use Electrocoagulation until complete closure is achieved and the polyp is guillotined. Best used for polyps 10-19 mm in diameter.
Hot Snare Polypectomy Technique
Hot snare polypectomy, which is using electrocoagulation on the basis of using cold snare. After hot polypectomy, another independent endoscopic surgeon judged whether the endoscopic eradication was successful. Afterward, additional EMR was performed at the polypectomy site to evaluate for the presence of residual polyp tissue,including an additional 1 to 2 mm clear margin, was resected by the snare and Endocut current after submucosal injection of a mixed solution.
Snare Polypectomy Procedure
In snare polypectomy, doctor will capture around the bottom of the polyp and use current to cut the growth off. Any remaining tissue or stalk is then cauterized.
Endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) techniques could be used on some polyps are considered more technically challenging or are associated with an increased risk of complications.
More kinds of endoscope accessories, please visit our website.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Single-use Balloon Dilatation Catheter (Rapid Exchange) Single-stage Dilatation Balloons | Used to dilate strictures of the biliary duct and the alimentary tract. Features of Single-use ercp catheter(Rapid Exchange) Single-stage Dilata... | |
| Polypectomy Snares (Hot & Cold) | Polypectomy snares are indicated for use endoscopically for the removal of polyps. Features of Endoscopy Snares(Hot & Cold) Snares are av... | |
| Polypectomy Snares (Hot & Cold) | Polypectomy snares are indicated for use endoscopically for the removal of polyps. Features of Endoscopy Snares(Hot & Cold) Snares are avai... | |
| Ligation Device | Ligation devicesis used for endoscopic therapy of gastrointestinal perforation, ESD/EMR assistance, bleeding control and the ligation of polyps. ... | |
| Single-use Nasal Biliary Drainage Catheter | Used for temporary endoscopic drainage of the biliary duct through the nasal passage by use of an indwelling catheter. Features of Single-use Na... |
Похожие товары
| High Precision Filter Infusion Set Sterile Disposable Clinical IV Therapy | Продавец: Hebei Zongkai Technology Co., LTD | Products DescriptionSterile Luer Lock Infusion Giving Sets IV Set Medical Intravenous Disposable ... | |
| High Precision Filter Infusion Set Sterile Disposable Clinical IV Therapy | Продавец: Hebei Zongkai Technology Co., LTD | Products DescriptionSterile Luer Lock Infusion Giving Sets IV Set Medical Intravenous Disposable ... | |
| Class I Sterile Test Tube PET Plastic Body Fluid Collection Clinical Use | Продавец: Hebei Zongkai Technology Co., LTD | Description of Disposable syringe: 1) Disposable syringe with three parts,luer lock or luer slip... | |
| Class I Sterile Test Tube PET Plastic Body Fluid Collection Clinical Use | Продавец: Hebei Zongkai Technology Co., LTD | Description of Disposable syringe: 1) Disposable syringe with three parts,luer lock or luer slip... | |
| Class I Sterile Test Tube PET Plastic Body Fluid Collection Clinical Use | Продавец: Hebei Zongkai Technology Co., LTD | Description of Disposable syringe: 1) Disposable syringe with three parts,luer lock or luer slip... |