Polypectomy Snares (Hot)
This device indicated for use endoscopically for the removal of polyps.
Features of Polypectomy Snares (Hot)
Snares are available in multiple shapes, stiffness ranging from 'soft' to 'Hard', as well as full range snare open width to meet different polyps cutting requirement.
Braided wires for excellent coagulation and bleeding control.
360° 1:1 rotation for precise adjustment.
Specification of Polypectomy Snares (Hot)
Rgeular items
|
REF |
Catheter |
Snare |
Stiffness |
Units/Box |
|||
|
Fixed |
Rotatable |
Catheter Diam. (mm) |
Working length (mm) |
Opening Width (mm) |
Configuration |
||
|
L16CA241815A0 |
L16RA241815A0 |
1800 |
15 |
Oval |
Soft |
10 |
|
|
L16CA241825A0 |
L16RA241825A0 |
1800 |
25 |
||||
|
L16CA241832A0 |
L16RA241832A0 |
1800 |
32 |
||||
|
L16CA242415A0 |
L16RA242415A0 |
2400 |
15 |
||||
|
L16CA242425A0 |
L16RA242425A0 |
2400 |
25 |
||||
|
L16CA242432A0 |
L16RA242432A0 |
2400 |
32 |
||||
|
L16CB241822A0 |
L16RB241822A0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832A0 |
L16RB241832A0 |
1800 |
32 |
||||
|
L16CB242422A0 |
L16RB242422A0 |
2400 |
22 |
||||
|
L16CB242432A0 |
L16RB242432A0 |
2400 |
32 |
||||
|
L16CC241825A0 |
L16RC241825A0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832A0 |
L16RC241832A0 |
1800 |
32 |
||||
|
L16CC242425A0 |
L16RC242425A0 |
2400 |
25 |
||||
|
L16CC242432A0 |
L16RC242432A0 |
2400 |
32 |
||||
|
L16CA241815B0 |
L16RA241815B0 |
1800 |
15 |
Oval |
Hard |
||
|
L16CA241825B0 |
L16RA241825B0 |
1800 |
25 |
||||
|
L16CA241832B0 |
L16RA241832B0 |
1800 |
32 |
||||
|
L16CA242415B0 |
L16RA242415B0 |
2400 |
15 |
||||
|
L16CA242425B0 |
L16RA242425B0 |
2400 |
25 |
||||
|
L16CA242432B0 |
L16RA242432B0 |
2400 |
32 |
||||
|
L16CB241822B0 |
L16RB241822B0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832B0 |
L16RB241832B0 |
1800 |
32 |
||||
|
L16CB242422B0 |
L16RB242422B0 |
2400 |
22 |
||||
|
L16CB242432B0 |
L16RB242432B0 |
2400 |
32 |
||||
|
L16CC241825B0 |
L16RC241825B0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832B0 |
L16RC241832B0 |
1800 |
32 |
||||
|
L16CC242425B0 |
L16RC242425B0 |
2400 |
25 |
||||
|
L16CC242432B0 |
L16RC242432B0 |
2400 |
32 |
||||
What is a Hot Snare Polypectomy
Hot snare polypectomy, the endoscopist advances the snare sheath, opens the snare and encircles the polyp. The snare is then slowly and progressively closed, with the aim of capturing 1-2 mm of normal tissue around the polyp,then use Electrocoagulation until complete closure is achieved and the polyp is guillotined. Best used for polyps 10-19 mm in diameter.
Hot Snare Polypectomy Technique
Hot snare polypectomy, which is using electrocoagulation on the basis of using cold snare. After hot polypectomy, another independent endoscopic surgeon judged whether the endoscopic eradication was successful. Afterward, additional EMR was performed at the polypectomy site to evaluate for the presence of residual polyp tissue,including an additional 1 to 2 mm clear margin, was resected by the snare and Endocut current after submucosal injection of a mixed solution.
Snare Polypectomy Procedure
In snare polypectomy, doctor will capture around the bottom of the polyp and use current to cut the growth off. Any remaining tissue or stalk is then cauterized.
Endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) techniques could be used on some polyps are considered more technically challenging or are associated with an increased risk of complications.
More kinds of endoscope accessories, please visit our website.
在线联系供应商
Other supplier products
| Sphincterotome | Used for cannulation of the ductal system and for sphincterotomy, if preloaded, also aids ERCP operation in the stenosis of bile duct difficult str... | |
| vSingle-use Biliary Draining Tubing | Used for endoscopic retrograde biliary drainage. Features of Single-use Biliary Draining Tubing Whole biliary drainage tubehas clear contrast i... | |
| Single-use Nasal Biliary Drainage Catheter | Used for temporary endoscopic catheterof the biliary duct through the nasal passage by use of an indwelling catheter. Features of Single-use Nasal... | |
| Single-use Stone Extraction Catheter- RX series | Used for endoscopic removal of biliary stones. Features of Single-use Stone Extraction Catheter- RX series High-quality latex increases the dur... | |
| Single-use Balloon Dilatation Catheter (Rapid Exchange) Progressive Dilation Balloons | LeoMed, a professional endoscopy accessories manufacturer, established by returnee in 2011, dedicated to developing and producing cost-effective, h... |
Same products
| R404a Scroll Compressor for Cold Chain Transportation | 卖方: Scroll Air Compressor,Electric Scroll Compressor | Optimized for Cold Chain Vehicles & Containers The34cc R404a scroll compressor for cold chai... | |
| Electric scroll compressor with R404a Refrigerant | 卖方: Scroll Air Compressor,Electric Scroll Compressor | Introduction Leling's compact refrigeration scroll compressor (18CC) is specially engineered for... | |
| Vapor Injection Compressor With Enhanced Enthalpy | 卖方: Scroll Air Compressor,Electric Scroll Compressor | The vapor injection compressor with enhanced enthalpy is a new type of compressor improved on the... | |
| R404a Refrigeration Compressor | 卖方: Scroll Air Compressor,Electric Scroll Compressor | R404a Refrigeration Compressor The refrigeration and freezing scroll compressor is a type of com... | |
| DC variable frequency electric scroll compressor | 卖方: Scroll Air Compressor,Electric Scroll Compressor | The electric scroll compressoris mainly composed of moving scroll plate, stationary scroll plate,... |